Data Logger
|
Analog Inputs
|
8 single-ended inputs, can configured individually for voltage measurement
|
Pulse Inputs
|
4
|
Voltage Excitation Terminals
|
3
|
Switched 12 Voltage
|
12
|
SDI-12
|
8
|
RS485 / RS232
|
4
|
Analog Voltage Accuracy
|
12-bit resolution, range 5000 mV, input impedance 50 kΩ, basic resolution 1.47 mV, accuracy ±(0.1% reading + 2 LSB) (-20 °C to +40 °C)
|
Power Supply
|
External battery 11–24 V DC
|
Communication Protocols
|
Modbus, RS485/RS232, SDI-12, and others
|
Internal Storage
|
32 MB, capable of storing 64,384 data points;(1 data per hour for 7.3 years)
|
Current Drain
|
Sleep: 0.24 mA; Idle: 4.6 mA; Measurement: 12 mA (excluding sensors); Network transmission: avg. 40 mA
|
Mobile Data Transmission
|
Supported, with built-in SIM card for LTE CAT1
|
Cloud Platform
|
Supported, with free cloud data storage, data processing, historical curve display, API data services, and private platform integration
|
GPS
|
Built-in high-precision GPS
|
Built-in Sensors
|
High-precision barometric pressure sensor, motherboard temperature monitoring
|
Dimensions
|
350 mm × 250 mm × 120 mm
|
Weight
|
4.5 kg
|
Operating Temperature
|
-20 °C to +70 °C (customizable to -40 °C)
|
Protection Rating
|
IP65
|
Lysimeter Tank
|
|
Dimensions
|
Inner tank: φ600 mm × 600 mm; Outer tank: φ800 mm × 800 mm
|
Material
|
Inner tank: SUS304 stainless steel; Outer tank: PP high-polymer
|
Sensor Ports
|
At 100 mm, 300 mm, and 500 mm depths
|
Weighing System
|
|
Weighing Range
|
0–500 kg
|
Measurement Resolution
|
Equivalent water depth variation of 0.01 mm
|
Infiltration
|
Equivalent water depth variation of 0.015 mm
|
Output
|
RS485/232
|
Measurement Method
|
Single-point
|
Drainage System
|
Flow Rate
|
1500 ml/min
|
Triangular Support
|
Overall Height
|
2 meters
|
Material
|
SUS304 stainless steel
|
Installation Rod Outer Diameter
|
42 mm
|
Power Supply System
|
Solar Panel
|
12 V, 60 W
|
Battery
|
12 V, 65 Ah (with buried box)
|
Data Transmission
|
Cloud platform
|
3 years –access free
|
Soil Sensors
|
Sensor quantity
|
3 sensors and placed at 100 mm, 300 mm, and 500 mm depths
|
Measurement Range
|
Moisture: 0.88–81.88%; Temperature: -40 °C to +80 °C; Conductivity: 0–23,000 us/cm
|
Protection Rating
|
IP68
|