Home >Products> Other Lab Equipments >Miscellaneous> Automation module
Other Lab Equipments:  Drug Tests / Pharmaceutics   Environmental Monitors   Food & Beverage   Radioactivity / Luminescence   Miscellaneous  
Automation module
Place of Origin:
France
Brand:
chromatotec
Model:
Price:
Hits:
819 
Updated:
8/26/2019
  • Product Detail
  • Company Profile

    The Automation module permits user defined automated computation. For example: Average computations, specific historical files, Logging files, alarm computation… Objective
    Automatic multiple compound average value computation of H2S ; RSH ; THT ; Total sulphur compounds and Odorization factor.

    General
    Analysis results are set in a Real Time DataBase (RTDB).
    The Math Module gathers these results with previous one, computes if necessary the averages values and other alarm triggering. All these data are also set in another place of the RTDB.
    The Modbus Driver continuously collects the data it needs from the RTDB and make them available to DCS or SCADA with Modbus protocol.
    To test the communication, the Modbus client requests need to be setup in the host DCS or PLC.
    The monthly historical files gather all substance results to be archive in CSV format which could be easily imported in a spreadsheet or a database.
    The calibration standard DMS results could be log on request in a monthly separated file.

    Alarm computing
    All alarm computing is performed at every result release.
    All alarm can be acknowledged from Vistachrom suite.
    All alarm thresholds are gathered into a dedicated .ini file.
    All alarm status changes are time stamped and logged into a monthly text file.

    Security handling
    Follow up of the calibration substance :
    ⇒ A deviation alarm against its target value is computed.
    ⇒ The target value is calculated after each calibration performed during the analyzer metrological follow up.

    Hardware fault handling :
    ⇒ The Math module watch for all error reported by the analyzer, check if it is a valid error and trigger a specific hardware alarm.
    ⇒ The alarm is trigged if the analyzer doesn’t deliver some result before a predefined delay.

    Software fault handling :
    ⇒ Every Vistachrom suite runtime program generates a life signal in the RTDB that could be reported to external DCS with the modbus driver. These life signals testify the full working of each softwares.
    ⇒ All hardware and software alarms are time stamped and logged in a monthly system text log file.

    bio-equip.cn
    For 40 years, Chromatotec, alliance of the expertise of three companies, Chromato-Sud, airmotec, Medor, is specialized in the manufacturing and sales of online gas analysers by chromatography.

    Worldwide known for its leading-edge of technology, our group proposes gas analysis systems with in-built computers and its own developed software, Vistachrom, to pilot these process analyzer.

    We manufacture several analyser ranges which mounted in 19" rack and 4U height with everything included in the instrument. Our main GC 866 ranges are :
    * MEDOR range : analysis of sulphur compounds in natural gas (gas company) and ambient air (waste water plant application) since 1975
    * AIRMO range : analysis of VOC / BTEX in ambient air (ppb, ppt, ppm)
    * CHROMA range : analysis of impurities in pure gas and in industrial air (ppb / %). This range has been developed since the creation of Chromato-Sud company in 1986.
    * DET range : Specific detectors.

    Chromatotec supplies complete cabinets with complementary instruments, in-built computer and appropriate accessories into a cabinet with air conditionning in option for accurate and complete compounds detection.

    Chromatotec proposes you global solutions with integration of automation systems (multiplexer, peripheral equipment, alarms, communication protocols…)
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.