W Series Refrigerating Circulator
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Maximum Pump Height(M) |
BILON-W-8001S |
-5~95 |
±0.1
|
80 |
20 |
Inner and External
|
29
Optional 48
|
48×45
|
7000 |
5500 |
10 |
BILON-W-8002S |
-10~95 |
60 |
7000 |
5500 |
10 |
BILON-W-8003S |
-20~95 |
60 |
7500 |
6200 |
10 |
BILON-W-8004S |
-30~95 |
60 |
7500 |
6200 |
10 |
BILON-W-8005S |
-40~95 |
50 |
7500 |
6200 |
10 |
BILON-W-8006S |
-60~95 |
50 |
12KW |
11KW |
10 |
BILON-W-8007S |
-78~95 |
50 |
12KW |
11KW |
10 |
BILON-W-8008S |
-100~95 |
50 |
12KW |
11KW |
10 |
BILON-W-8009S |
-120~95 |
50 |
12KW |
11KW |
10 |
Parameters:
Model No. |
|
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Pump Height(M) |
BILON-W-5001S |
-5~95 |
±0.1 |
50 |
60 |
Internal and External |
34 |
40×42 |
5000 |
3500 |
5.6 |
BILON-W-5002S |
-10~95 |
60 |
5000 |
3500 |
5.6 |
BILON-W-5003S |
-20~95 |
60 |
5000 |
3500 |
5.6 |
BILON-W-5004S |
-30~95 |
60 |
6500 |
4400 |
5.6 |
BILON-W-5005S |
-40~95 |
50 |
6500 |
4400 |
16 |
BILON-W-5006S |
-60~95 |
50 |
6800 |
6000 |
16 |
BILON-W-5007S |
-78~95 |
50 |
6800 |
6000 |
16 |
BILON-W-5008S |
-100~95 |
50 |
6800 |
6000 |
16 |
BILON-W-5009S |
-120~95 |
50 |
6800 |
6000 |
16 |
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Maximum Pump Height(M) |
BILON-W-3001S |
-5~95 |
±0.1 |
30 |
45 |
Inner and External |
34 |
35×35 |
3800 |
1800 |
4.6 |
BILON-W-3002S |
-10~95 |
45 |
3800 |
1800 |
4.6 |
BILON-W-3003S |
-20~95 |
45 |
3800 |
1800 |
4.6 |
BILON-W-3004S |
-30~95 |
45 |
3800 |
2200 |
4.6 |
BILON-W-3005S |
-40~95 |
40 |
3800 |
2200 |
6 |
BILON-W-3006S |
-60~95 |
40 |
4000 |
2500 |
6 |
BILON-W-3007S |
-78~95 |
40 |
4000 |
2500 |
6 |
BILON-W-3008S |
-100~95 |
40 |
4000 |
2500 |
6 |
BILON-W-3009S |
-120~95 |
40 |
4000 |
2500 |
6 |
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Pump Height(M) |
BILON-W-2001S |
-5~95 |
±0.1 |
20 |
27 |
Internal and External |
29 |
30×30 |
2300 |
1200 |
3 |
BILON-W-2002S |
-10~95 |
27 |
2300 |
1200 |
3 |
BILON-W-2003S |
-20~95 |
27 |
2300 |
1200 |
3 |
BILON-W-2004S |
-30~95 |
27 |
3000 |
1600 |
3 |
BILON-W-2005S |
-40~95 |
40 |
3000 |
1600 |
6 |
BILON-W-2006S |
-60~95 |
40 |
3000 |
1600 |
6 |
BILON-W-2007S |
-78~95 |
40 |
3500 |
2000 |
6 |
BILON-W-2008S |
-100~95 |
40 |
3500 |
2000 |
6 |
BILON-W-2009S |
-120~95 |
40 |
3500 |
2000 |
6 |
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Pump Height(M) |
BILON-W-1001S |
-5~95 |
±0.1 |
10 |
11 |
Internal and External |
24 |
25×25 |
1600 |
800 |
1.5 |
BILON-W-1002S |
-10~95 |
11 |
1600 |
800 |
1.5 |
BILON-W-1003S |
-20~95 |
11 |
1600 |
800 |
1.5 |
BILON-W-1004S |
-30~95 |
11 |
1800 |
1200 |
1.5 |
BILON-W-1005S |
-40~95 |
40 |
1800 |
1200 |
6 |
BILON-W-1006S |
-60~95 |
40 |
2200 |
1750 |
6 |
BILON-W-1007S |
-78~95 |
40 |
2200 |
1750 |
6 |
BILON-W-1008S |
-100~95 |
40 |
2200 |
1750 |
6 |
BILON-W-1009S |
-120~95 |
40 |
2200 |
1750 |
6 |
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave(°C) |
Volume(L) |
Max Flow(L/M) |
Circulating Way |
Opening Size |
Container Size |
Heating Power(W) |
Refrigeration0°C/w |
Pump Lift(M) |
BILON-W-801S |
-5~95 |
±0.1 |
8 |
8 |
Internal and External
|
24 |
25×18 |
1200 |
600 |
10 |
BILON-W-802S |
-10~95 |
1200 |
600 |
BILON-W-803S |
-20~95 |
1200 |
600 |
BILON-W-804S |
-30~95 |
1500 |
900 |
BILON-W-805S |
-40~95 |
1500 |
900 |
BILON-W-806S |
-60~95 |
1600 |
1250 |
BILON-W-807S |
-78~95 |
1600 |
1250 |
BILON-W-808S |
-100~95 |
1600 |
1250 |
BILON-W-809S |
-120~95 |
1600 |
1250 |
Parameters:
Model No. |
Temp. Range(°C) |
Temp. Wave
(°C) |
Volume(L) |
Maximum Flow
(L/min) |
Circulating Way |
Opening
(cm) |
Container Size(cm) |
Heating Power(W) |
20°C refrigeration
(W) |
Pump Height(M) |
BILON-W-501S |
-5~95 |
±0.1 |
5 |
11 |
Internal and External |
19 |
20×20 |
1200 |
600 |
1.5 |
BILON-W-502S |
-10~95 |
11 |
1200 |
600 |
1.5 |
BILON-W-503S |
-20~95 |
11 |
1200 |
600 |
1.5 |
BILON-W-504S |
-30~95 |
11 |
1500 |
900 |
1.5 |
BILON-W-505S |
-40~95 |
40 |
1500 |
900 |
6 |
BILON-W-506S |
-60~95 |
40 |
1600 |
1250 |
6 |
BILON-W-507S |
-78~95 |
40 |
1600 |
1250 |
6 |
BILON-W-508S |
-100~95 |
40 |
1600 |
1250 |
6 |
BILON-W-509S |
-120~95 |
40 |
1600 |
1250 |
6 |
Bilon is specialized in manufacturing and selling thermostatic equipment, photochemical product, ice maker, ultrasonic instrument, spray dryer, extracting device and so on.
After 6-year developing, we has gained increasing domestic market share and enjoyed good reputation in the industry, our products are applied to a lot of universities and scientific research facilities in many fields.
bio-equip.cn