AELAB CEMS-2000 B FT Flue Gas Analyzer – Industrial FTIR Solution
provides precise multi-component flue gas analysis using advanced Fourier Transform Infrared (FTIR) technology. Engineered for power plants, refineries, and industrial emission systems, it delivers continuous, real-time monitoring of pollutants such as SO₂, NOx, CO, CO₂, O₂, and more.
Featuring anti-corrosion optics, 180 °C high-temperature operation, and automatic power-loss protection, the system ensures stable and safe performance in harsh industrial environments while maintaining compliance with international environmental standards.
Category Insight: Advanced gas analysis systems for environmental monitoring, process optimization, and compliance control.
🔗 Explore related category
Technical Features and Specifications
| Feature |
Specification |
| Measurement Principle |
Fourier Transform Infrared (FTIR) Spectroscopy, real-time multi-gas detection |
| Measured Gases |
SO₂, NO, NO₂, NH₃, HCl, HF, CO, CO₂, H₂O, O₂ (customizable ranges) |
| Measurement Range (example) |
SO₂ 0–200 mg/m³; NO 0–400 mg/m³; CO₂ 0–20%; O₂ 0–25% |
| Response Time |
≤180 s for SO₂, NOx, CO, CO₂ (50 m heat tracing line) |
| Accuracy / Drift |
Zero drift ≤±2% F.S./7 days; Span drift ≤±2% F.S./7 days |
| Operating Temperature |
Up to 180 °C (anti-condensation design) |
| Ambient Conditions |
5–40 °C; 20–90% RH |
| Flow Rate |
3 L/min sample gas; 250 L/min compressed air (0.4–0.7 MPa) |
| Optical System |
5 m White cavity with anti-corrosion mirrors; ROCKSOILD interferometer |
| Power Supply |
AC 220 V ±10%, 50 Hz; Main cabinet power: 2 kW |
| Output Interfaces |
4–20 mA, RS232/RS485, Ethernet (DCS/SCADA integration) |
| Protection Function |
Automatic protection against sudden power failure and corrosion damage |
| Dimensions |
19" standard cabinet |
Applications: Continuous emission monitoring in power generation, refineries, and heavy industries; environmental compliance verification; combustion optimization; and process safety assessment in high-temperature gas systems.
FAQ
Q: How is calibration performed?
A: Calibration uses certified standard gases with programmable zero and span routines for automated accuracy assurance.
Q: Is the system GMP or EPA compliant?
A: The CEMS-2000 B FT is configurable to meet EPA CEMS and ISO 14956 standards, ensuring full regulatory compliance.
Q: What is the warranty period?
A: AELAB provides a 12-month standard warranty with optional extended service contracts.
Q: Is the system suitable for high-humidity environments?
A: Yes. The HMS-100 module provides accurate H₂O/O₂ readings up to 40% humidity, featuring integrated condensation prevention.
Q: Can it integrate with existing DCS/SCADA systems?
A: Absolutely. Supports 4–20 mA, RS232/RS485, and Ethernet interfaces for seamless connectivity.
Learn more: Visit AELAB CEMS-2000 B FT Flue Gas Analyzer