AELAB Melting Point Apparatus MP420 integrates high-resolution video capture with precise melting point determination, displaying real-time video and temperature curves with save/replay for verification.
Suited to chemical and pharmaceutical labs, it ensures reliable, reproducible results for drugs, spices, dyes, and other organic crystals.
Android-based system with large 8" touchscreen, 0.1°C resolution, and multi-interface data output (USB/RS232/network). Handles up to 4 samples per batch and meets pharmacopoeia and GLP requirements.
Category Insight: Video melting point systems for regulated and research laboratories requiring archival evidence (video + curve) and 21 CFR Part 11 options.
🔗 Explore related category
Technical Features and Specifications
| Feature |
Details |
| Models & Temperature Range |
MP420: RT–300°C | MP430: RT–350°C | MP450/MP470/MP490: RT–400°C |
| Resolution / Repeatability |
0.1°C resolution; 0.2°C repeatability at 0.2°C/min |
| Temperature Accuracy |
±0.4°C (<200°C); ±0.7°C (<300°C) |
| Heating Gradient |
0.1–20.0°C linear ramp (selectable) |
| Video & Optics |
720P high-resolution camera, 8× magnification; supports dark samples |
| Display & OS |
8" color touchscreen; Android-based UI |
| Capacity per Batch |
4 pcs / batch; standard capillary I.D. 1.0 mm, O.D. 1.4 mm |
| Interfaces & Data |
USB×2, RS232, Wi-Fi, RJ45; export via U-disk & network; print supported |
| Storage Capacity |
MP420: 8 G | MP430/MP450: 16 G | MP470: 32 G | MP490: 128 G |
| Method / Curve Storage |
Up to 200 methods (model dependent); up to 500 curve groups (MP490) |
| Video Recording |
20 min per run (MP430/MP450/MP470/MP490) |
| User / Compliance |
Account authorization & operator accounts (model dependent); FDA 21 CFR Part 11 on MP430/MP470/MP490 |
| IQ/PQ/OQ |
Optional (MP420–MP470); Included (MP490) |
| Power / Supply |
100 W; 100–240 V, 50/60 Hz |
Applications: Pharmaceutical QC, chemical R&D, university teaching labs, food & dye analysis, and general organic crystal characterization.
FAQ
Q: How is calibration done?
A: Use certified reference materials to perform calibration and document per GLP procedures for traceable accuracy.
Q: Is the device GMP compliant?
A: Models MP430, MP470, and MP490 support FDA 21 CFR Part 11 requirements for electronic records/signatures, aligning with regulated GMP lab workflows.
Q: How long is the warranty?
A: One-year standard warranty; extended service plans are available.
Learn more: Visit AELAB Melting Point Apparatus MP420
📞
Contact AELAB
Get Expert Advice or Order Now ☎️
🌐 Website: www.aelabgroup.com
📧 Email: info@aelabgroup.com
📱 WhatsApp / WeChat: +86 15800016110
🔎 Need help selecting the right model? Our technical team can recommend MP420/430/450/470/490 based on compliance and storage needs.