AELAB 4530F Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer
Advanced AAS for precise multi-element quantification with floated optical platform stability, automatic 8-lamp turret, and PC-controlled flame/graphite furnace workflows.
Deuterium background correction, rapid wavelength scanning, and robust data handling (>500 records) support high-throughput environmental, pharmaceutical, and metallurgical testing.
Category Insight: Atomic absorption spectrophotometers for trace metal analysis with flame, graphite furnace, and hydride options.
🔗 Explore related category
Technical Features and Specifications
| Feature |
Details |
| Optical System |
Single-beam on floated optical platform for anti-vibration stability |
| Wavelength Range |
190–900 nm; scanning grating 1800 lines/mm |
| Spectral Bandwidths |
0.1, 0.2, 0.4, 1.0, 2.0 nm selectable |
| Wavelength Accuracy / Repeatability |
±0.15 nm / ≤0.04 nm |
| Baseline Stability (Cu) |
≤0.002 A / 30 min |
| Sensitivity & Detection (Cu) |
Characteristic 0.02 μg/ml/1%; detection limit ≤0.004 μg/ml |
| Lamp Turret |
Automatic 8-position turret with preheating & auto selection |
| Background Correction |
D2 lamp; 1 A background reduced ≥50× (self-absorption method) |
| Atomization (Flame) |
All-metal titanium burner 100 mm; effective glass atomizer; ignition drift ≤0.006 A/30 min |
| Flame Precision (Cu) |
RSD ≤0.5% (A > 0.8); detection limit ≤0.008 μg/ml |
| Graphite Furnace (4510GF) |
Up to 3000 °C; heating rate ≥2000 °C/s; Cd ≤0.5×10−12 g, Cu ≤0.5×10−11 g; accuracy Cu/Cd ≤3% |
| Control & Software |
Full PC control; auto wavelength scanning; method/result storage >500; Excel/report print |
| Safety Interlocks |
Auto gas cut-off (low pressure), power-fail & flameout protection; burner mismatch detection |
| Interfaces / Options |
USB, RS-232; hydride generator, chiller, air compressor (optional) |
| Power |
Main unit 220 V ±22 V AC; graphite furnace 220 V ±22 V AC, 7000 W |
| Dimensions (Pkg.) |
Main 860×705×755 mm; Accessories 1170×645×900 mm |
Applications: Environmental monitoring (water/soil), food safety, agricultural nutrients, pharmaceutical formulation, metallurgical alloy control, and biochemical research — compliant with ISO, GLP, and CE quality standards.
FAQ
Q: What is the wavelength range of the AELAB 4530F?
A: 190–900 nm, covering common resonance lines for multi-element metal analysis.
Q: Does it support both flame and furnace?
A: Yes. Standard flame AAS with optional 4510GF graphite furnace for ultra-trace measurements.
Q: How many lamps can be installed?
A: An 8-lamp automatic turret enables quick switching and simultaneous preheating.
Q: What is the Cu detection limit?
A: ≤0.004 μg/ml (flame); characteristic 0.02 μg/ml/1%.
Q: What safety features are included?
A: Automatic gas cut-off, power-fail protection, flameout protection, and burner mismatch safeguards.
Q: What data handling functions are available?
A: On-board storage for >500 records/methods, USB/RS-232 connectivity, Excel export, and printouts of parameters, results, and spectra.
Learn more: Visit AELAB 4530F Atomic Absorption Spectrophotometer
📞
Contact AELAB
Get Expert Advice or Order Now ☎️
🌐 Website: www.aelabgroup.com
📧 Email: info@aelabgroup.com
📱 WhatsApp / WeChat: +86 15800016110
🔎 Need guidance on flame vs. graphite furnace methods? Our technical team can help tailor a configuration to your analytes and detection limits.