Home >Products> Other Lab Equipments >Miscellaneous> SOLVENT RECYCLER
Other Lab Equipments:  Drug Tests / Pharmaceutics   Environmental Monitors   Food & Beverage   Radioactivity / Luminescence   Miscellaneous  
SOLVENT RECYCLER
SOLVENT RECYCLER
Place of Origin:
China
Brand:
Automatic Science Instrument Co,.Ltd
Model:
SRJ-20A
Price:
Hits:
1954 
Updated:
8/26/2008
  • Product Detail
  • Company Profile
    THE MEDILAB SRJ-20A SOLVENT RECYCLER

    Intelligent mobile phase recycling is accomplished by placing an electrically actuated Recycle Valve in the fluid path between the HPLC detector and the solvent waste reservoir. The signal processor in the Recycler SRJ-20A, which monitors the detector signal to determine when peaks and other contaminants are passing through the detector flow cell, controls the valve.

    When a contaminant is detected, the Recycle Valve is diverted the waste solvent container. When no contaminants are present, the Recycle Valve sends clean solvent back to the mobile phase reservoir for reuse.

    ADVANTAGE
    Using SRJ-20A solvent Recycler, you will quickly recover your initial investment and continue enjoying substantial savings for years to come. While decreasing the pollution of waste to the environment.

    THE FEATURES

    ¨ Recycling mobile phase is more than 90%
    ¨ Manual control and remote control can recycle mobile phase or waste directly.
    ¨ The purity of mobile phase can be controlled precisely by the 4-degree Threshold switch.
    ¨ Time delay of the valve switch can be set from10 to 90 seconds.
    ¨ The selectable three-range input degrees match various HPLC detectors.
    ¨ The polarity and the change of level of detecting signals are indicated by LED light and illuminant tape.
    ¨ Auto zero (it can match with the detector zero point automatically).

    PARAMETERS

    SRJ-20A has three parameters that can be chosen by users.
    1.RANGE
    SRJ-20A''s input range (10mV, 100mV or1v) matches the HPLC detector''s full-scale output range.

    2.THRESHOLD

    When the detector''s output signal exceeds the selected THRESHOLD value (0.1%, 0.5%, 1%, 5% of full scale) indicating a peak is present, the Recycle Valve sends the contaminated detector effluent to waste container. The Recycle Valve returns to the recycle position after the detector signal falls below the THRESHOLD value and the TIME DELAY has elapsed.

    3.TIME DELAY

    It holds the Recycle Valve in the waste position for the specified amount of time (10,20,until 90 seconds) after the detector signal drops below the THRESHOLD valve. The TIME DELAY accounts for tailing peaks and plumbing volume between the detector and the Recycle Valve. Set these three parameters, and SRJ-20A operates accurately and reliably with little or no intervention.
    The connection of SRJ-20A as the following:
    The SRJ-20A Solvent Recycler returns clean mobile phase to mobile phase reservoir for reuse or sends chromatographic peaks to waste container.

    SRJ-20A SOLVENT RECYCLED SPECIFICATIONS

    Recycle Valve: 2 Position Electrically Actuated
    All wetted parts are PEEK and TFE
    Fittings are 1/16", 1/4"-28 Flange-Free
    Max Flow: 50mL/Min (As supplied with 1.5M1/16"

    Tubing on each port).
    Analog Input: 10mV, 100mV and 1V
    Display: Red and Green LED''S
    Zero setting: Automatic Zero Setting
    Remote input : Switch or TTL Signal
    Power: 13.5Volts DC/500mA
    Dimensions: 7.28"L × 6"W × 2.7"H (18.5cmL × 14.2cmw × 6.28Hcm)
    Weight: 2.21bs (1.0kg)
    bio-equip.cn
    Today, the company has products in the country with a considerable number of users and have a good reputation in North America, the Asia Pacific region has started mass marketing, and this shows that our team's efforts have been recognized by the majority of users.

    My company developed and produced a series of AT column incubators, SRJ-20A solvent recovery device, AS series of ultrasonic cleaning machine, AL series solvent filters, AP series of oil-free vacuum / pressure pumps, AM series magnetic stirrer, WB Series boiling water bath, MH series Incubator, UH cells smash series of ultrasonic device, ATP Series peristaltic pump, ANASTAR chromatography data processing workstations and other products have a good and stable performance and quality;

    In addition, the company also has the technical expertise for technical advice and maintenance staff to ensure that you enjoy the use of high quality after-sales service. To meet the changing and growing needs of customers, we will be a long-term commitment to product development and updated to bring you the most efficient use and the most significant results, and work toward the future together with you and the broader world. Finally, we have to thank loyal to the use of our products and our products will use all users.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.