Home >Products> Lab Water | Ultrafilters | Concentration | Reaction >Reaction Kettle / Glass Reactor > 2L RE-2000A TOPTION Rotary Evaporator China low price
Lab Water | Ultrafilters | Concentration | Reaction:  Lab Water   Ultrafilters   Concentration / Rotary Evaporators   Reaction Kettle / Glass Reactor  
2L RE-2000A TOPTION Rotary Evaporator China low price
2L RE-2000A TOPTION Rotary Evaporator China low price
Place of Origin:
China
Brand:
TOPTION INSTRUMENT CO., LIMITED
Model:
2L RE-2000A
Price:
Hits:
1359 
Updated:
4/14/2017
  • Product Detail
  • Company Profile

    2L RE-2000A TOPTION Rotary Evaporator China low price

    RE-2000A Rotary Evaporator
    Rotary Evaporator is the use of vacuum pressure, constant temperature heating conditions, using the rotating bottle constant speed rotation, the formation of large area thin film, high evaporation equipment installations.

    Rotary evaporator is mainly used for pharmaceutical, chemical and bio-pharmaceutical industry concentration, crystallization, drying, separation and dissolution of coal recovery. The principle is: in a vacuum condition, constant temperature heating, to rotate bottles constant rotation, the material in the sidewall formation of large area thin film, high evaporation. Solubilization by high glass condenser vapor cooling, recovery in the collection bottle, greatly improve the efficiency of evaporation, particularly easy to use in high-temperature decomposition of the variability of biological products Purifying

    Key Features
    Rocker plate button: toggle main board under the Ministry of pressure rise, toggle press the host fall under the subordinates. With ring nuts: smooth rotation automatically fasten rotating bottle, reverse rotation axis of rotation speed shifting. Stepless speed regulation.

    Technical parameters

    Type

    RE-2000A

    Host

    plate buttons, fast automatic lift 0-150mm

    Speed

    Speed digital 20-200r/min

    The heating pot

    Teflon composite pan ,fullyenclosed heater,power 1.4KW

    Temperature range

    Automatic temperature control, temperature digital display, RT-90

    condenser

    vertical, high-temperature high-quality glass I double back a ball off of Condenser, large diameter airway, improve the efficiency of evaporation

    power

    1.5kw

    voltage

    220V 50/60Hz

     

    Relevant Model

    RE-52A

    RE-52AA
    RE-52AAD

    RE-2000A
    RE-2000AD

    RE-3000A
    RE-3000AD

    RE-5203
    RE-5203D

    RE-5203A
    RE-5203AD

    RE-5205
    RE-5205D

    RE-5000
    RE-5000D

    Rotating Flask(L)

    0.5L

    0.5L

    2L + 1L

    3L + 2L

    3L

    3L

    5L

    5L

    Optional Rotating Flask(L)

    0.1L, 0.25L, 1L or 2L

    0.1L, 0.25L, 1L or 2L

    0.1L, 0.25L, 0.5L

    0.5L, 1L

    2L, 1L

    2L, 1L

    3L, 2L, 1L

    3L, 2L, 1L

    Receiving Flask(L)

    0.5L

    0.5L

    1L

    2L , 1L

    1L

    1L

    3L

    3L

    Lifting Type

    Hand lifting

    Automatic lifting

    Automatic lifting

    Automatic lifting

    Hand lifting

    Automatic lifting

    Hand lifting

    Automatic lifting

    Condenser

    Vertical

    Vertical

    Vertical

    Vertical

    Vertical

    Vertical

    Vertical

    Vertical

    Rotation Speed (rpm)

    0-150

    0-150

    20-200

    20-200

    0-150

    0-150

    0-150

    0-110

    Max Evaporating Speed (H2O)

    1.2L/H

    1.2L/H

    1.2L/H

    1.5L/H

    1.5L/H

    1.5L/H

    2L/H

    2L/H

    Reachable Vacuum Rate

    <399Pa (3.99 mbar, 3 Torr)

    Bath Power (kw)

    1.1KW

    1.1KW

    1.5KW

    1.5KW

    1.5KW

    1.5KW

    2.2KW

    2.2KW

    Staic Temp. Control Range & Wave (℃)

    RT-99±2

    RT-99±2

    RT-99±2

    RT-99±0.2

    RT-99(150)±0.2

    RT-99(150)±0.2

    RT-99(150)±0.2

    RT-99(150)±0.2

    Power

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    220V 50/60Hz

    * Note: Max evaporating speed is affected by operation setting and the performances and matching levels of supporting equipment.
    "A"-Automatic lifting,  "D"-150℃ Oil Bath,  "EX"-Explosion Protection, "AD"-Automatic Lifting 150℃ Oil Bath,  "AEX"-Automatic Lifting Explosion Protection.

     

     

    1. What's the most important performance of rotary evaporator?

     

    Air impermeability is the first important performance of rotary evaporator, which directly affect rotary evaporator normal operating and service life. Air impermeability is good or not is decided by suppliers' design standard, manufacture standard and material choice, etc. "Actual vacuum degree" and "vacuum pressure maintaining time" are the measuring standard.

     

    2. What's the difference of glass lifting and bath lifting?

     

    Bath lifting is more safe, the glass parts matched with rotary evaporator are not easy to be damaged, don't need to lock after lifting finished. Glass lifting is mainly suitable for the rotating flask which has fixed size, lifting height is fixed, after finish lifting, need to lock.

     

    3. #29 and #24 Evaporation bottle grinding mouth, choice which type is better?

     

    ISO #29 and ISO #24 both are the standard mouth for laboratory. ISO #29 has high strength and convenient to clean, is more suitable for imported rotary evaporator, and also benefit you to choice flask move device.

     

    4. Which type vacuum pump is most suitable for rotary evaporator?

     

    Vacuum pump is the prerequisite device for rotary evaporator, TOPTION provide SHB-III vacuum pump for 1L ~ 10L laboratory rotary evaporator,  SHB-B95 vacuum pump for industrial rotary evaporator, and 2XZ also supplied for rotary evaporator, etc. But using cold trap or other methods provide corrosion protection is more better.

     

    5. In which situation, condensation effect is best?

     

    Tap water temperature changes as different season, its temp. is higher in summer, so solvent recovery efficiency is low, and tap water will make condenser change color and scale formation.

     

    You could choice the below two lab solutions:

    1) The best solution: equip appropriate low temperature cooling circulating pump, when you choice, please pay attention to "refrigerating capacity", "lowest temperature", "circulating joint", "circulation capacity" and "circulating pressure", TOPTION supply low temperature equipment professional for rotary evaporator.

    2) For laboratory rotary evaporator, cold trap could be cooling by ice.

     

    6. How to improve rotary evaporator service life?

     

    1) Please operating based on TOPTION rotary evaporator operation instruction.

    2) After finish research, please clean rotary evaporator in time.

    3) The surface of rotary evaporator should be keep clean.

    4) Please contact TOPTION specialist for any problems during rotary evaporator operating.

     

    We Believe TOPTION will be your TOP OPTION !!!

    bio-equip.cn
    TOPTION INSTRUMENT CO.,LTD is the famous integrated equipment supplier in Chinese equipment field. After years of development, it has become a research, development, production and sales as one of the independent legal personality diversified technology group. We believe TOPTION will be your TOP OPTION!!!
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.