Chilled Mirror Dew Point Instruments DP29
Applications:
DP29 is a multifunctional, portable dew point humidity meter , especially designed for field use.
Typically apply to dew point measurement of SF6gas.
Based on the principle of chilled mirror.
* Accurate measurement is guaranteed.
* The system is stable, No need to repeatedly calibrated.
* A built in electronic sample gas flow monitor.
* Use RS-232 data output to connect with PC.
Features:
DP29-40 is specifically designed for air dew point measurement. It is applicable to standard reference for electronic componentdurability , dew point control for firing furnaces, dew point control for fuel cell test system, etc.
DP29-SF6 is specially for the measurement of Sulfur Hexafluoride (SF6).
DP29-60 is a standard type. It applies to standard reference for laboratory calibration, moisture control for ceramic firing furnaces,humidity control for thermo-hygrostat chamber.
DP29-70 is a high-end type. It is suitable for moisture control of drying process, production process of lithium ion battery,measurement of gas with low dew point.
For rapid quotation,please contact Lisa directly :
To Lisa email: lisali0428@outlook.com
skype: lisali0428@outlook.com
Details:
| Model |
DP29-40 |
DP29-60 |
DP29-SF6 |
DP29-70 |
| Range |
Under 0°C |
-40°C |
-60°C |
-60°C |
-70°C |
| Under 10°C |
-40°C |
-60°C |
-60°C |
-65°C |
| Under 20°C |
-35°C |
-55°C |
-55°C |
-60°C |
| Under 35°C |
-30°C |
-45°C |
-45°C |
-50°C |
| Accuracy |
≤±0.2°C,±1Digit |
| Repeatability |
≤±0.1°C,±1Digit |
| Resolution |
0.1°C |
| Default Output |
USB |
| Optional Output |
±10mv/°C (0°C= 0mv) or 4-20mA |
| Measurement Principle |
Chilled Mirror |
| Refrigeration |
Semiconductor Refrigeration |
| Inlet Flow |
15~60L/h, Generally 30~40L/h |
| Inlet Pressure |
10mbar~10bar (1kpa~1Mpa) |
| Response Time |
2°C/Second (Maximum) |
| Pump |
Optional Accessory |
| Mirror Check |
Press the Mode Conversion Key to mirror check mode (‘CH’ on the display), and check manually |
| Instrument Check |
Press the Test Cooling Key, open the measurement probe, and check manually at mirror check mode. |
| Voltage |
220VAC±10%,50/60HZ |
| Consumption |
About 160 Watts |
| Temperature |
0~50°C |
| Humidity |
<90% , No Condensation |
| Weight |
About 7.22kg |
| Dimension |
342(W)x140(H)x326(D) mm |
Accessories:
Standard Accessories:
1. Main Unit
2. Inlet Tube (FEP,3m), With Connector
3. Instruction Manual
4. Packaging Box
Optional Accessories:
1. USB, RS-232 data cable with software
For rapid quotation,please contact Lisa directly :
To Lisa email: lisali0428@outlook.com
skype: lisali0428@outlook.com