    The Total Aflatoxin Quantitative Rapid Test Kit provides a fast, accurate, and EU-standard-compliant solution for detecting total aflatoxins (B1, B2, G1, G2) in grains, feed, herbs, and nuts.
    With results in 3–5 minutes and accuracy equivalent to LC-MS/MS, it’s ideal for on-site or laboratory use.
    Trusted in over 10 million global tests, it ensures EU MRL compliance, saves cost and time, and delivers consistent, reliable results.


    Product Overview
    The Total Aflatoxin Quantitative Rapid Test Kit is a high-precision food safety testing tool designed to quickly detect total aflatoxins (B1, B2, G1, G2) in grains, feed, herbs, and nuts.
    Built under strict EU MRL and ISO standards, it offers laboratory-level accuracy comparable to LC-MS/MS — yet simple enough for on-site large-scale screening.
     
    Validated in over 10 million applications worldwide, this test kit is trusted by food exporters, laboratories, and inspection agencies for reliable, cost-effective toxin monitoring.
     

     
     Key Features
    ✅Rapid Results (3–5 Minutes) – Perform fast, on-site testing anytime.
    ✅ High Accuracy – Quantitative results equivalent to LC-MS/MS analysis.
    ✅ EU Standard Compliant – Meets EU Maximum Residue Limit (MRL) and CE/ISO certifications.
    ✅ Proven Reliability – Verified through 10+ million successful tests globally.
    ✅ Cost-Effective – Reduce testing expenses without sacrificing accuracy.
    ✅ User-Friendly – Simple operation, no special equipment required.
    ✅ Dual Use – Ideal for both on-site screening and professional lab verification.
    ✅ Environmentally Safe – Non-toxic reagents, safe for users and samples.
     
     
    Applications
    Perfect for detecting total aflatoxin contamination in:
    • Grains & Cereals: Corn, wheat, rice, barley, maize
    • Nuts & Beans: Peanuts, soybeans, almonds, cashews
    • Herbs & Spices: Dried herbs, chili, bran, herbal feed
    • Animal Feed & Raw Materials
    • Food Production, Quality Control & Export Inspection
     
     
    Global Use & Recognition
    This aflatoxin rapid test kit is widely used by food safety laboratories, exporters, feed manufacturers, and inspection agencies across Europe, Asia, and the Americas.
    Its EU-certified reliability and stable performance make it a top choice for regulatory compliance and export inspection.
     

     
    Why Choose Us
    • 20+ Years of Rapid Test Manufacturing Expertise
    • CE, ISO Certified Quality System
    • OEM / Private Label Options Available
    • Full Technical Support & Documentation
    • Fast Global Delivery & Long-Term Supply Guarantee

     
    STORAGE AND STABILITY
    Store at room temperature(4-30℃).
    DO NOT FREEZE or use beyond the expiration date.
    The shelf life is 15 months.

    KIT CONTENTS
    -SmarKIT Total Aflatoxin Rapid Test (40/50 tests /kit)
    -Plastic dropper (40/50 pieces /kit)
    -PBST Buffer (1 bottle/kit, 30ml)
    -Buffer A (1 bottle/kit, 15ml)
    -Packing Insert (1 set /kit)

    TEST PROCEDURE
    Read the entire procedure carefully before performing any test.
    Keep the test kit and reagent at room temperature(20℃~30℃) before testing.

    1. Prepare samples according to chapter 7 (Sample preparations).
    2. Remove the Total Aflatoxin Rapid Test from sealed pouch.
    3. Hold the dropper vertically and transfer 3 full drops(around 100µL) of solution to the specimen well (S) and then start the timer.
    4. Wait for red bands to appear. The result should be read in approximately 3-5 minutes. Do not interpret results after 5 minutes.
     

    READ RESULTS WITH NAKED EYES

    NEGATIVE:

    The Test Line (T) is the same as or darker than the Control Line(C). It is negative.

    POSITIVE:

    The Test Line (T) is lighter than the Control Line(C),or there is no Test Line. It is positive.

    INVALID:Reference Line Fails to appear

    Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result.

    Review the procedure and repeat the test with a new test kit. Stop using the test kit immediately if the problem is not solved and contact your local distributor.


     
    bio-equip.cn
    Established in 2005, NKBIO Group Co., Ltd. is a national high-tech enterprise dedicated in developing, manufacturing and marketing Rapid Test Kits in Food and Feed Analysis, Animal Disease as well as Clinical Diagnostics.

    The Rapid Tests can detect the animal disease, residues of antibiotics, mycotoxins, veterinary drugs, pesticides, microorganism, heavy metal, illegal additives and toxic chemicals in all kind of foods and feeds. It is an accurate, cost-effective method as a screening solution, useful for both labs and field testing, can also be applied for the quality control “From farm to fork”.

    NKBIO have three Advanced Third Party Independent laboratories to guarantee, further confirm the results from the preliminary Positive & Negative Samples, have capability to issue formally, official testing reports which acknowledged by both government authority and academic institutions.

    With Rapid Testing Branch, Software Engineering & Equipment Branch and Service of complete solution Branch, we have successfully built Food & Feed Quality Management Traceability System for regulation of Government Authority and Enterprises.

    NKBIO values the innovation, have widely technological and scientific research cooperation with national top-level universities and scientific research institutes, like Zhejiang University, Jinan University, South China Agricultural University, Academy of Agricultural Sciences. We have published many of technical literatures, got hundreds of prizes & certificates, and also undertaken making rules and regulations for Food and Feed testing standards for government authority.


    For more information please visit:

    www.nkbiotech.com
    http://www.foodrapidtest.com

    E -mail: sale@nkbiotech.com
    bellafu88@yahoo.com
    WhatsApp:0086-151-5809-6930

Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.