    Usage

    Specimen Requirements

    1. Specimens should be extracted as soon as possible after collection, following the relevant literature. Experiments should be performed as soon as possible after extraction. If experiments cannot be performed immediately, specimens may be stored at -20°C, but repeated freezing should be avoided.

    2. Samples containing sodium nitrate (NaN3) cannot be assayed, as NaN3 inhibits horseradish peroxidase (HRP) activity.

    Procedure

    1. Dilution of Standard: This kit provides one standard sample at full strength. Users can dilute the sample in a small test tube according to the following chart.

    4μg/L

    Standard No. 5

    150μl of original standard was added to 150μl of standard diluent

    2μg/L

    Standard No. 4

    150μl of standard No. 5 was added to 150μl of standard diluent

    Standard No. 3

    Add 150μl of Standard No. 4 to 150μl of Standard Diluent

    0.5μg/L

    Standard No. 2

    Add 150μl of Standard No. 3 to 150μl of Standard Diluent

    0.25μg/L


    Calculation

    Draw a standard curve on graph paper with the concentration of the standard as the horizontal axis and the OD value as the vertical axis. Find the corresponding concentration of the sample from the standard curve based on the OD value of the sample; then multiply it by the dilution factor; or use the concentration of the standard and the OD value to calculate the linear regression equation of the standard curve, substitute the OD value of the sample into the equation to calculate the sample concentration, and then multiply it by the dilution factor to obtain the actual concentration of the sample.


    Standard Curve

    Sensitivity0.05 μg/L
    Species ReactivityChinese hamster
    SynonymChinese hamster PLBL2/PLBD2 ELISA Kit
    Detection TypeUsed to determine the content of phospholipase B-like 2 (PLBL2) in hamster serum, plasma and related fluid samples.
    Composition

    Serial number

    Component name

    Specification

    Serial number

    Component name

    Specification

    1

    30 times concentrated detergent

    20ml×1 bottle

    6

    Developer B solution

    6ml×1/bottle

    2

    Enzyme Labeled Reagent

    6ml×1 bottle

    7

    Stop Solution

    6ml×1 bottle

    3

    Enzyme-coated plate

    12 wells ×8 strips

    8

    Standard (8 μg/L)

    0.5 ml ×1 bottle

    4

    Sample diluent

    6 ml ×1 bottle

    9

    Standard diluent

    1.5ml×1 bottle

    5

    Developer A Liquid

    6ml×1 bottle

    10

    Sealing film

    2 photos

    General Notes1. After removing the kit from the refrigerator, allow it to equilibrate at room temperature for 1 hour before use. If the enzyme-coated plate is opened and not completely used, store it in a sealed bag. 2. Crystals may form in the concentrated wash buffer. Warming in a water bath during dilution can aid dissolution. This will not affect the results during washing. 3. Use a pipette for each sample addition step and frequently calibrate its accuracy to avoid experimental error. The time for each addition should ideally be within 5 minutes. For large numbers of samples, using a dispenser is recommended. 4. Execute a standard curve with each measurement, preferably in duplicate. If the analyte content in the sample is too high (the sample OD value is greater than the OD value of the first standard well), dilute the sample a certain number of times (n times) with sample diluent before measurement. When calculating the final dilution, multiply by the total dilution factor (×n×5).

    5. The sealing film is for single use only to avoid cross contamination.

    6. Please store the substrate in a dark place.

    7. Strictly follow the instructions for operation. The test results must be determined based on the readings of the microplate reader.

    8. All samples, washing solutions and various wastes should be treated as infectious materials.

    9. Components of different batches of this reagent must not be mixed.

    Storage Temp.Unopened test kit, stored at 2-8°C, has a shelf life of 6 months.
    Test Range0.15μg/L-5μg/L
    bio-equip.cn
      AntBio is a biotechnology group company dedicated to serving life sciences, aiming to help scientists accelerate research and improve work efficiency. AntBio provides comprehensive and high-quality reagent tools for basic research, drug development, and diagnosis, including research grade antibodies, proteins, biochemical reagents, and assay kits. These research tools are widely used in different segments of life science research. The group company currently consists of three brands, Absin, Starter-Bio and UA-Bio.
    Request Information
    Request Information: yes no
    Request Quotation: yes no
    refresh

    I agree to share my inquiry with the other matching suppliers.

    Request Information

    * Name:
    Job Title:
    * Tel:
    Fax:
    * E-mail:
    Postcode:
    Institution/Company:
    Address:
    * Country:
    Request Information:
    yes no
    Request Quotation:
    yes no
    * Message:
    * Verification Code:
    refresh
    I agree to share my inquiry to the other matching suppliers.