    PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.

    PCR Cabinet Features:

    1. Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.

    2. Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15,30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.

    3. Ergonomic Control Panel Location, centered and angled down for an easy reach & viewing.

    4. The non-direct light source design can effectively relieve the operator's visual fatigue under the condition of ensuring the illumination.

    5. Brushed stainless steel work surface is for easy cleaning

     

    Safety Performance:

    1. Audio and visual alarm on filter life, UV life etc.

    2. Front sliding sash interlock with fan and UV lamp.

    3. Front sash and side windows are made of UV-resistant tempered glass.

    4. The host and sockets have independent capacitors to prevent current overload.

     

    Humanized design:

    1. Standard shelves with IV bar.

    2. Memory function in case of power-failure.

    3. HEPA filter and UV life indicators facilitate a timely replacem ent plan.

    4. Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.

    5. Equipped with temperature sensor to show the real temperature during operation.

    6. Waterproof socket provide convenience for small instruments to be used in the operating area.

     

    PCR Cabinet Specifications:

    Model PCR-1100 PCR-1300 PCR-1600 PCR-1900
    External Size (WxDxH)(mm) 1050x710x1850 1320x710x1850 1625x710x1850 1930x710x1850
    Internal Size (WxDxH)(mm) 950x615x625 1220x615x625 1525x615x625 1830x615x625
    Work Surface Height 750mm
    Control System Display Microprocessor controller with LCD display, display the operating status of each function
    Alarm Audio and visual alarm on filter and UV changing
    Interlock Front sliding sash interlock with fan and UV lamp
    Life Indicator HEPA filter and UV life indicators facilitate a timely replacement plan
    Airflow System Airflow Velocity 0.2~0.5 m/s, speed adjustable
    Air filtration System Pre-Filter 1pcs, Polyester fiber,washable
    HEPA Filter 1 pcs, Efficiency: > 99.995% at particle size of 0.3μm
    Cleanliness Grade ISO Class 5 (formerly Class 100)
    Partial air circulation Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
    Cabinet Construction Main Body Electro-Galvanized steel with antimicrobial powder coating
    Work Surface 304 Stainless steel
    Front Window Manual sliding sash: 5 mm UV resistant tempered glass
    Side window 5 mm UV resistant tempered glass
    Electrical System UV Lamp 20W×1 30W×1 30W×1 20W×2
    With timing function from 0 to 999 minutes, Interlock with front sliding sash.
    Emission of 253.7 nanometers for best sterilization effect.
    LED Lamp 8W×2 12W×2 12W×2 12W×2
    Consumption 155W 285W 285W 300W
    Not include socket loading power consumption
    Power Supply AC220V±10%, 50/60HZ; 110V±10%, 60Hz
    Illumination ≥900Lux
    Sound Emission ≤62dB(A)
    Standard Accessory 1.Base Stand; 2.LED Lamp; 3.UV Lamp; 4.Waterproof Socket×2
    Optional Accessory Gas Tap
    Gross Weight (kg) 225 255 285 330
    Shipping Size (W×D×H)(mm) 1190x990x1325 1460x990x1325 1765x990x1325 2070x990x1325
    Shipping Volume (m3) 1.56 1.92 2.3 2.7

    FAQ:

    1. Difference between dead-air PCR cabinet and Scitek PCR cabinets?

    Dead-air PCR cabinet are non-ventilated enclosure with dead-air inside the work zone. Scitek PCR cabinets provide HEPA-filtered vertical laminar airflow to the work zone.

     

    2. Can PCR cabinet be used when working with microorganism?

    No. PCR cabinets do not provide user protection and cannot be used with infectious materials. These are mainly used for Polymerase Chain Reaction (PCR) experiments, such as PCR master mix and reagent preparation and amplification

     

    3. Difference between Scitek vertical laminar flow cabinet and PCR cabinet?

    Both vertical laminar flow cabinets and PCR cabinets provide ISO Class 5 (formerly Class 100) conditions in the work zone for the sample protection. PCR cabinet have standard shelves with IV bar for more convenience of PCR preparation and amplification work.  

     
    bio-equip.cn
    Scitek Global is professional manufacture of Laboratory Instruments and Medical Devices, certified by ISO9001, ISO13485 and ISO14001. Products are certified by ETL, CE and FDA etc.

    We look forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value. Together we will be different.
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.