GeneHunterTM Features:
High Performance:
Open platform, excellent stability and repeatability. Extracting difference between wells: CV≤3%. High extraction efficiency and purity.
Intuitive Operation:
Comes with a 7-inch Android tablet and a variety of preset and customizable extraction methods, which can meet almost all needs for nucleic acid extraction experiments and easily control the whole extraction process. With a powerful and easy-to-use APP, operation is extremely simple.
Flexibility:
Various menu display, viewing and selection mode (list view / grid view / shortcut keys). Allow creating and modifying extraction methods to meet the needs of different reagents & samples.
Speed & Throughput:
Extract 32 samples at the same time, in 15-60 minutes. Upgrade from 32 to 48 throughput can be easily achieved by replacing the module.
Safety:
Built-in UV disinfection and air duct, reduce the risk of cross-contamination. Automatically detect the opening/closing status of the safety door, further avoid cross-contamination. After the safety door is opened, immediately turn off the UV lamp to protect users.
Temperature:
Instrument use precise temperature control technology, with 8 independent heating zones. Free setting the lysis and elution temperature according to needs. Temperature sensor accuracy can reach ±0.1℃.
Technical Specification:
Model |
LT32 |
Physical |
Dimension (W × D × H) |
40 cm × 40 cm × 45 cm |
Package size (W × D × H) |
65 cm × 54 cm × 56 cm |
Net weight |
35 kg |
Power supply; Consumption |
100-240V~, 50 / 60Hz; 600W |
Environmental |
Operating conditions |
Temperature: 10~40℃ (50~104℉), Relative Humidity: 10%~90% non-condensing |
Sample parameters |
Sample throughput |
1-32 | 1-48 |
Well plate type |
96-well deep well plate, 2.2 mL sterile, enzyme-free; adapted to single 6-well kit |
Processing volume |
20 ~ 1000 μL |
Reagent type |
Open platform for magnetic bead method |
Magnetic bead recovery |
>98% |
Extracting difference between wells |
CV≤3% |
Extraction time |
15-60 min/batch samples (dependent upon reagent used) |
Hardware |
Module replaceable |
Yes |
Heating temperature |
Eight independent heating zones, customize lysis and elution temperature (temperature range: RT ~ 120℃) according to user needs, and the temperature sensor accuracy can reach ±0.1℃. |
Oscillating mixing |
Three speeds adjustable (low, medium, high), and the fluctuation amplitude can be adjusted with the reagent volume. |
Safety door design |
Automatically suspend the running process when the safety door is opened, and continue to run after the safety door is closed, avoid cross-contamination. |
Built-in air duct |
HEPA filters in the built-in air duct, significantly reduce the risk of cross contamination. |
Power failure protection |
Support power failure protection, continue to run after power is restored. |
Flashlight |
Yes |
Ultraviolet irradiation |
Yes. UV disinfection with two timing modes, freely set the disinfection time. |
Software |
Internal method |
Can store >500 groups of methods. Can set a method to start from any step, no need to re-edit the method. |
Method management |
Powerful method editing & management capabilities to meet the needs of different samples and reagents, methods can be imported and exported via U disk. |
Menu display |
List view / grid view / shortcut keys |