    Information Biological Data acquisition and processing system is controlled by one multi-singlechip that specialized design for life sciences,it replaced traditional physiological recorder,oscilloscope,X-Y recorder and stimulation instrument and so on,it widely used on physiology,pharmacology,pathphysiology,exercise physiology,psychology and other disciplines biological experimental of high school,it can operate under Windows2000/XP/win7 and do animals blood pressure,tension,electrocardiograph(ECG) and other 300 types indicators.

    Characteristics:

    1.Lower noise,lower drift and higher performance amplifier,strong anti-interference ability,good linearity,higher measure precision.

    2.Using full speed USB 2.0 plug,easy to use.

    3.Four channel 16-bit A/D collection synchronous,analysis results accurately.

    4.Bus structure,common slot and can combination 4-8 channel amplifier and 1-2 channel stimulator flexible.

    5.Drive program supports Windows2000/XP/Vistas/win7

    6.Drive program added real-time digital signal processing b

    7.Virtual channel design,channels original data, differentiation,integration,frequency,average image synchronous display in real-time.

    8.Multithreading mechanism runs,even in high speed continuous collection,you can also adjust various parameters and runs other software.

    9.Added guide of experimental configuration and easy to operate.

    10.Source opening,user can freely custom various experiments.

    11.User can freely custom the result processing and personally design.

    12.User can custom experiment record process and experiment record easily.

    13.Optimized data processing module and faster data processing speed also real-time processing.

    14.Smart data processing module design,more convenient to result processing.

    15.Optimized printing module,network printing more smoothly.

    16.Supporting networked experiment,Neteeting user can control the experiment process through network

    17.Seamless joint to Microsoft Word Excel Access,with medicine statistics function.

    18.Specialized experiment include postsynaptic potentials (EPSP) collection and analysis module, myocardial cable measuring traumatic rat tail, no determination of arterial blood pressure and myocardial effective refractory period, intracellular calcium dynamics analysis animals \ hard breathing lung function measurements tidal volume (volume), lower limb motor function, muscle strength reserve analysis, discharge stack, hemodynamic comprehensive test.

    Technical parameters:

    1.Dropping record:Any channels can record total dropping quantity,speed,also any time period qty and speed.
    2.Using full speed USD 2.0 plug,easy to use.
    3.Four channel 16-bit A/D synchronous collection,analysis result accurately.four channel signal output,it can make four channel signal output to other equipment in same time.
    4.Bus structure,common slot and can combination 4-8 channel amplifier and 1-2 channel stimulator flexible.
    5.Monitor function;four channel freely monitor.
    6.Virtual channel design,channel’s original data, differentiation,integration,frequency,average image synchronous display in real-time. 
    7.Stimulator technical indicator:range:0-100m,length:1mv,bandwidth:0.1-6000ms,unit adjusting length:0.1ms.working way:single stimulation,bunch stimulation,mainly cycle stimulation,automatic interval adjusting stimulation,automatic range adjusting stimulation,automatic bandwidth adjusting stimulation,automatic frequency adjusting stimulation.stimulation view:after selected stimulation parameter,used can view stimulation pulse’s range and bandwidth qty.
    8.Software function:multi-window function,set window qty freely,each window is a separately system and have nothing to do with hardware,it can take former experiment data to analysis processing in real-time,Collection,compression and handle data respectively.
    9.Easy to optimize various experiments.
    10.File recycle function:for previous curve,if forgot save or the computer happen some special condition,it can recycle files,experiment data can user-defined keep time,when need you can recycle unsaved or broken file’s experiment data,ensuring the experiment will not lose in any condition.
    11.Ecg function: through the software, it can also be switched to the whole-lead electrocardiogram amplifier in real time, complete the collection and processing of ecg signals, and switch the lead mode of the software. Ecg measurement function: it can process the ecg heart rate, P amplitude, PR period, QRS duration, ST, T amplitude and QT, and can directly enter into Excel, SPSS, SAS and other processing software.
    12.Seamless joint to Microsoft Word Excel Access,with specialized processing software module of medicine statistic function,various processing method,precision.for different biological signal that with real-time and special processing method and smaller result error. There are many special analytical algorithms in the field of neuroelectrophysiology, electromyography and pharmacological toxicology of new drugs.


    13.File printing function: can edit the experimental curve arbitrarily, save, seven print edit mode and full file pre-cable printing function. Can edit the graphics and the text size, the graph of the coordinates form, color and other graphic properties. And can add, delete, copy, copy the graph arbitrarily.
    14.Data export function: can export the experimental data, the configuration of experimental parameters, etc., and can draw out some of the necessary channels to export separately. Signals that are too large for sampling can also be compressed by time to compress the data
    15.Biological signal collection processing system can install and run in Window 7
    16.High integration, using the USB2.0 interface, completely rid of the built-in, mobile convenience, convenient research
    17.Record channel number: 4 high performance amplifier record channel, same performance
    18.16-bit A/D conversion chip, single channel hardware maximum sampling rate of 1000KHz, hardware minimum sampling rate 0.01Hz.
    19.Low noise: the equivalent input noise voltage peak value < 1.1.50μV, the signal noise ratio >80dB
    20.AC and DC have same gain:range ±0.5V——±20μV
    21.Adopt 5 order bessel low pass filtering.
    22.Time constant including:DC 3s-0.001s
    23.The cascade of 2~4 devices can be automatically carried out to form the new equipment of the new 8-16 sampling channel to improve the cost performance of the product without any additional cost.
    24.The physiological, pharmacological and pathophysiological experimental items were set up in advance, and the number of experimental projects was not less than 60
    25.The sampling rate can be changed at any time during the real-time sampling process
    26.1 -31 display channels can be set according to the user's needs (5-31 channels can be used for analysis)
    27.It can be used with microcirculator, and observe microcirculation and blood pressure changes, and used for study of acute hemorrhagic shock.


    28.It has the function of three - dimensional spectrum analysis and used for research work of gastrointestinal electricity
    29.Special experiments include: postsynaptic potentials (EPSP) collection and analysis module, the determination of myocardial cable characteristics, no traumatic rat tail artery blood pressure measurement and the measurement of myocardial effective refractory period and intracellular calcium dynamics analysis of animal \ hard breathing lung function measurements tidal volume (volume), lower limb motor function, muscle strength reserve analysis, comprehensive test discharge stack, hemodynamics, median lethal dose (LD50, dose logarithm linear regression with probability unit method), the median lethal dose (LD50, Bliss method) median lethal dose (ED50), pD2 and pA2 values.

    bio-equip.cn
    Established in 2004,headquarter in Anhui, branch in Beijing, Shanghai we are a professional manufacturer, Serving the basic medical and biological research field for animal experiment equipment development, production, sales and service as a professional technical enterprise
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.