Login    Join free Add to favorites    中文
Home >Products> Microscopes >Biomicroscopes> BioCAM DupleX
BioCAM DupleX
BioCAM DupleX
Origin of place Switzerland
Model
Supplier 3Brain AG
Price
Hits 1009
Updated 3/8/2022
  • Product Detail
  • Company Profile
Where the functional screening revolution begins

Introducing a fully bi-directional microelectrode array platform for 2D and 3D invitro imaging
BioCAM DupleXHD-MEA Chip - 3Brain
Overview
In vitro electrophysiology reimagined

BioCAM DupleX is a state-of-the-art, high-resolution microelectrode array (also known as multielectrode array) platform for powerful in vitro functional imaging.

Its bidirectional electrodes make it possible to simultaneously record high-density electrophysiological data at 20 kHz and induce electrical neural network stimulation from any of the 4,096 microelectrodes.

This advanced platform works with both classical planar 2D cell culture as well as our innovative 3D HD-MEA technology.

The BioCAM DupleX is compatible with our latest generation of Khíron chips, which feature 4,096 µNeedle electrodes to penetrate structured brain tissues and obtain signals from inside your biological models such as slices, organoids, or spheroids.

Our journey to perfection
1 product, 15 years of R&D

BioCAM DupleX is the result of 15 years of research and development, embodying our experience in bioengineering CMOS microelectrode array (MEA) devices, electrophysiology, data processing and biological models.
It is electrophysiology at its best.

BioCAM IDEA

BioCAM Idea
2004

BioCAM 4096

BioCAM 4096
2012

BioCAM X

BioCAM X
2015

BioCAM DupleX

BioCAM DupleX
2019

 

Electrophysiology in 3D
An ideal match: BioCAM DupleX and Khíron

The BioCAM DupleX is the first Microelectrode Array platform of its kind able to power 3D high-density CMOS-MEA chips.

With the Khíron microchip family developed by 3Brain, the BioCAM DupleX can simultaneously record and stimulate from all 4,096 microelectrodes structured in a penetrating µNeedle grid.


These revolutionary µNeedle electrodes access information from inside all kinds of tissues – such as slices, organoids, spheroids and scaffolded 3D cultures – without damaging them, making the BioCAM DupleX the only platform for high-resolution in vitro 3D functional imaging.

Electrophysiology revolutionized

Complex electrophysiology setups, where the wiring of a single electrode to the amplifier can significantly change the noise level and impair the experiment, or where the interpretation of the signals coming from your setup is restricted to electrophysiological experts, are now a distant memory.

BioCAM DupleX makes setup as easy as possible by automating important settings and optimizing noise, thus making electrophysiology accessible to everyone. Complex electrophysiological traces are then converted into microscopy-like, easy-to-understand, fast-to-process functional images.

BioCAM DupleX - the most compact bidirectional platform sending and actuation with 4096 electrodes per well.
Sensing and actuation with 4,096 electrodes

Bidirectional platform

Whenpaired with the HD-MEA from the Khíron family (Accura HD-MEA), the BioCAM DupleX can use any of the recording sites to release an electrical stimulus, thus making it a fully bidirectional platform.

Coupled with BrainWave, our unique integrated software for recording, stimulation and real-time processing, BioCAM DupleX is the perfect solution for easily setting up complex experiments. Study functional connectivity, information processing or complex behaviors like learning and memory in neuronal networks – all without the need for external stimulating electrodes or third-party electronics.

Touch button and LED interface

Precision at your fingertips

After inserting a microelectrode array (HD-MEA) chip into the BioCAM DupleX, the motorized locking mechanism activates with a simple press of the lock button to enable precise contact and alignment. The system automatically recognizes the MEA chip and is ready to acquire data.

BioCAM Duplex - LED and touch button interface

A convenient set of LED lights shows whenthe BioCAM DupleX is powered on, whether the MEA chip is locked in and when the system is recording.

 
A close-up view
Integrated reference

The BioCAM DupleX features an integrated reference electrode for the microelectrode array (MEA) chip to simplify the experimental procedure, reducing the risk of contamination, interference noise and accidental spills of media.

Under the case

Hover on the BioCAM DupleX to discover more.

REAL-TIME PROCESSING

Advanced FPGA control to denoise, filter and compress high-density data

MAGNETIC SURFACES

All surfaces around the MEA chip are magnetic for easy setup with other equipment, such as perfusion holders

TEMPERATURE CONTROL

Integrated heating and cooling system

Temperature control - Integrated heating and cooling systemMagnetic Surface - All the surfaces around the MEA chip are magnetic for easy setup with other equipment, such as perfusion holdersReal time processing - Advanced FPGA control to denoise, filter and compress high-density data.Integrated Stimulator - 4 independently programmable current stimulator channelsFast locking system - A motorized solution to reliably lock and unlock your microelectrode array (MEA) chipsBioCAM DupleX BaseBioCAM DupleX - discover more of all the features within this compact microelectrode array device
 
 
 
 
 
INTEGRATED STIMULATOR

4 independently programmable current stimulator channels

FAST LOCKING SYSTEM

A motorized solution to reliably lockand unlock microelectrode array (MEA) chips

ROBUST EXTERNAL CASE

Crafted from aluminum to shield from electromagnetic and mechanical interference

Perfect fit in any setup
Compact design for maximum impact

The BioCAM DupleX high-resolution microelectrode array (HD-MEA) platform is packed with features to enrich your research. At the same time, its small footprint makes for easy integration with instruments like microscope and perfusion or patch-clamp systems.

W 230 mm/9.5''
D 180 mm/7.08''
H 42 mm/1.65''

BioCAM DupleX - overall compact design
BioCAM Duplex - front viewBioCAM Duplex - side viewBioCAM Duplex - back view
Resources
Here you can find useful resources for your BioCAM DupleX
BioCAM DupleX Brochure
 
Tech specs
Main Controller
Computational core
Intel®'s Arria® 10 FPGA 13Gbps, 2GB DDR4,
and ARM® dual-core Cortex™-A9 1.5 GHz
 
Data resolution
12 bit
 
Number of simultaneous recording channels
4096
 
Sampling frequency (full-array)
20 kHz/electrode
 
Region-of-interest
1 - 4 independent subsets of electrodes (up to 64kHz sampling frequency)
 
Temperature control
Active heating and cooling system
 
Data interface
USB 3.1 Type-C
 
Ground reference
On-chip integrated
 
HD-MEA compatibility
Prime, Arena, Stimulo, Accura
 
3D HD-MEA compatibility
Accura 3D (firmware upgrade required)
 
Control software compatibility
BrainWave 4 or higher
 
Inputs
Two analog inputs (-3.3 V to 3.3 V) or triggers (LV-TTL)
 
Stimulation Module
Integrated current stimulator
Yes
 
Real-time stimulation controller
Yes
 
Number of independent channels
4 (2 int. and 2 ext.)
 
Internal (on-chip) stimulation sites
4,096 (only with HD-MEA Accura)
 
External stimulation sites
2 (accessible with optional connector box)
 
Maximum amplitude
+/- 1 mA
 
Amplitude resolution
10 µA
 
Time resolution
10 µs
 
Physical specs
Body material
Anodized aluminum and stainless steel
 
Locking mechanism
Motorized
 
Protection from liquid spill over
Anti spill barrier v. 2
 
Dimensions
(W x D x H)
180 x 230 x 42 mm / 7.09 x 9.05 x 1.65 inches
 
Weight
2 Kg / 4.4 pounds
 
 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号