Login    Join free Add to favorites    中文
Home >Products> Other Lab Equipments >Radioactivity / Luminescence> X-ray Diffractometer (x ray diffraction analyzer) (XRD) for powder and other material analysis
X-ray Diffractometer (x ray diffraction analyzer) (XRD) for powder and other material analysis
X-ray Diffractometer (x ray diffraction analyzer) (XRD) for powder and other material analysis
Origin of place China
Model AL-Y3500A
Supplier Dandong Aolong Group
Price
Hits 477
Updated 3/6/2024
  • Product Detail
  • Company Profile

1. Features of x-ray diffraction analyzer (XRD)

● High stable X-ray source: The instrument uses an X-ray generator to improve the stability of the diffractometer measurement results;

● Long life X-ray tube: metal ceramic X-ray tube, with good heat dissipation, high operating power (40kV×40mA), and long service life characteristics;

● High precision goniometer: The diffraction angle drive, adopting stepper motor drive plus with optical coding control technology, has accurate positioning and measurement; The hidden design of the goniometer makes the instrument look more neat, beautiful, and generous; In the measuring range of diffraction angle, the linearity is less than 0.02°.

● The accessories to broaden the application field of the diffractometer are complete: the installation of high-temperature, low-temperature, multi-functional accessories achieve "plug and play". The software automatic identification technology is convenient for operators to use the instrument;

● Safety and reliability of X-ray protection: The X-ray protection device is safer and reliable, the X-ray protection door is forbidden to open when the sample is measured, and the double protection can protect the operator from radiation.

  • Main technical parameter           
  • X-ray generator                     
  • Rated output power: 2KW (standard)
  • Voltage: 10 ~ 50kV
  • Current: 5 ~ 40m 
  • Stability of voltage: better than ±0.005%

(when outer voltage fluctuation is 10%)

  • X-ray tube: metal ceramic X-ray tube
  • Focus size: 1×10mm
  • Cu target: power 2.4kW (standard configuration).
  • High precision goniometer
  • Goniometer: θ/θ sample is horizontally placed,
  • Adopts incremental encoder reading technology
  • Diffraction radius: 225 (standard configuration)
  • Scanning mode: continuous, step-by-step
  • 2θ Measuring range: -10° ~ 160° (standard configuration)
  • Minimum step-angle: 0.0001°
  • Maximum corner speed 20°/s,
  • Measurement linearity of diffraction angle ≤0.01°
  • Repeatability error ±0.0001°
  • Angle reproducibility: 0.0001°
  • Maximum positioning speed: ≤1200°/min
  • Measurement linearity of diffraction angle ≤0.01°
  • Detector
  • Scintillation detector: (standard configuration)
  • It is necessary to configure a monochromator sometimes to effectively remove the Kβ line,
  • Maximum linear count: ≥5×105CPS,
  • Spectral resolution: ≤50%.

Contact: boblhh999@163.com

whatsapp: +86 13898510966

WEBSITE LINK

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号