Login    Join free Add to favorites    中文
Home >Products> Incubators | Drying ovens >Other Incubators & Ovens> OLABO Infant Incubator BK-3201
OLABO Infant Incubator BK-3201
OLABO Infant Incubator BK-3201
Origin of place China
Model
Supplier Medbase (Shandong) Biotech Co., Ltd
Price
Hits 464
Updated 7/14/2022
  • Product Detail
  • Company Profile
Features:

1.LCD display

2.Double control modes of bed temperature and skin temperature

3.Double-layer thermostatic cover, automatic air curtain device

4.Humidity control function

5.Air & Oxygen blender

6.Oxygen supply system

7.Baby cot is infinitely adjustable

8.24 kinds of sound and light alarm, comprehensive protection of baby safety

Parameter
 

neral parameters Item Specifications
Power supply AC220V,50/60Hz(Standard) 1320VA; 110V 60Hz(Optional)
Size(L*W*H) 950*645*(1250-11450) mm
Maximum heater output power(220VAC) Air chamber heater:330W; Water tank heater:155W
Auxiliary network power output AC220V/50Hz, both maximum permissible currents are 220V 1.5A
Heater indication 0~100%, 10% increasing amount
Temperature control mode Bed temperature mode; skin temperature mode
Bed temperature control range 25.0~37.0℃; 37.1~39.0℃(Span mode)
Skin temperature control range 34.0~37.0℃;37.1~38.0℃(Span mode)
Skin temperature sensor display range 5.0~65.0℃
Heating time ≤ 50min
Temperature variability ≤ 0.5℃
Temperature uniformity (mattress in horizontal position) ≤ 0.8℃
Temperature uniformity (mattress in tilted position) ≤1.0℃
Difference between average incubator temperature and control temperature ≤1.5℃
Skin temperature sensor accuracy ±0.3℃
Humidity control The running time of the tank after it is filled with distilled water Humidity below 70%RH, at least 24h
Water tank capacity 1500ml
Humidity display range 0%RH~99%RH
Humidity control range CAH%RH~90%RH(1% per adjustment)
Humidity control accuracy ±10%
Oxygen concentration control Oxygen concentration display range 0%~99%
Oxygen concentration display resolution 1%
Oxygen concentration control accuracy ±5% oxygen volume concentration
Oxygen concentration setting range 21% ~ 60% (1% per adjustment)
Oxygen sensor service life The maximum use time is 10000h at 100% oxygen concentration
Transport storage Temperature -20℃~+55℃
Atmospheric pressure range 500hPa~1060hPa
Relative humidity ≤93%RH
Packing size/ Gross Weight Base packing size: 1200*800*870mm 50Kg
Body packing size: 1100*710*855mm 60Kg
The work environment Relative humidity 30%RH~75%RH
Environment temperature +20℃~+30℃
Pressure range 700hPa~1060hPa
Service altitude ≤2000m
Overvoltage category
Pollution level 2
Ambient air velocity ≤ 0.3m/s
Other indicators Ambient noise in the infant compartment of the incubator No more than 55dB(A) at stable temperature
Carbon dioxide concentration in the infant compartment A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after stabilization
The velocity of air flow over the baby mattress ≤0.35m/s
General
alarm
Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm
System alarm Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号