Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Glyphosate Rapid Test Kit for Soybean, Corn, Grain & Fruit | On-Site Residue Screening
Glyphosate Rapid Test Kit for Soybean, Corn, Grain & Fruit | On-Site Residue Screening
Glyphosate Rapid Test Kit for Soybean, Corn, Grain & Fruit | On-Site Residue Screening
Origin of place China
Model
Supplier Nankai Biotech Co., Ltd.
Price
Hits 61
Updated 5/9/2026
  • Product Detail
  • Company Profile
The Glyphosate Rapid Test Kit is designed for fast on-site screening of glyphosate residues in key agricultural commodities, especially soybean, corn/maize, wheat, beans, coffee, feed raw materials and export-oriented fruits.
 
It is especially suitable for raw material intake inspection, grain processing, feed production, fruit packing houses, export pre-shipment screening and pre-LC-MS/MS risk control.
 
In real agricultural trade, the biggest risk is often not testing itself, but discovering a high-risk batch too late — after storage, processing, packing, shipment or buyer inspection.
 
This rapid screening solution helps QC teams identify potential glyphosate residue risks earlier, so that high-risk batches can be separated, further confirmed, or prevented from entering production and export channels.
 

 
Main Testing Matrices
 
Grain, Soybean & Feed Applications
 
Main matrices include:
 
* Soybean
* Corn / Maize
* Wheat
* Beans
* Coffee
* Soybean meal
* Feed raw materials
* Oats
* Rice
* Sugarcane-related raw materials
 
Best suited for:
 
* Grain processors
* Feed mills
* Soybean crushing plants
* Food manufacturers
* Agricultural trading companies
* Exporters
* QC laboratories
 

 
Fruit Applications
 
Main matrices include:
 
* Banana
* Citrus / Orange
* Mango
* Papaya
* Apple
* Grape
* Strawberry
* Passion fruit
* Guava
* Pineapple
 
Best suited for:
 
* Fruit exporters
* Packing houses
* Fresh produce suppliers
* Juice / puree / concentrate processors
* Export farms
* Importers and wholesale buyers
 

 
Key Application Scenarios
 
1. Raw Material Intake Screening
 
For soybean, corn, wheat, beans, soybean meal and feed raw materials.
 
Helps processors, feed mills and crushing plants screen incoming raw materials before storage or production, reducing the risk of high-residue batches entering the supply chain.
 

 
2. Export Pre-Shipment Screening
 
For grain, soybean, corn and fruit exporters.
 
Helps identify potential glyphosate residue risks before shipment, container loading, customs inspection or buyer acceptance, reducing the risk of rejection, claims or shipment disputes.
 

 
3. Packing House & Fruit QC
 
For banana, citrus, mango, papaya, apple, grape and other fruit lots.
 
Helps packing houses and fruit exporters check different farm lots before grading, packing, cold storage or export preparation.
 

 
4. Pre-LC-MS/MS Screening
 
For laboratories and QC teams handling many samples.
 
Helps users screen high-risk samples first, reduce unnecessary laboratory workload and prioritize samples that require confirmatory LC-MS/MS testing.
 

 
 
Item Description
Detection Target Glyphosate
Detection Type Qualitative / Semi-quantitative with reader
Main Applications Grain, soybean, corn, fruit, feed raw materials
Key Grain Matrices
Soybean, corn/maize, wheat, beans, soybean meal, feed raw materials
Key Fruit Matrices
Banana, citrus, mango, papaya, apple, grape, strawberry
Result Reading Visual / Optional reader-assisted interpretation
Use Scenario Raw material intake, export screening, packing-house QC, pre-LC-MS/MS screening
Storage 4–30°C
Shelf Life 15 months
Operation On-site rapid screening
 

 
Laboratory-Backed Screening Solution
 
We are not only a rapid test strip supplier.
 
Our strength lies in an integrated system covering in-house R&D, large-scale manufacturing, colloidal gold rapid screening technology and independent laboratory verification.
 
With our own laboratories equipped with LC-MS/MS and GC-MS/MS systems, we are able to evaluate the consistency between rapid screening results and laboratory reference methods in validated applications.
 
This supports product optimization, matrix verification and long-term reliability for real agricultural supply chains.
 
For professional users, this means the product is not just a simple strip, but a practical pre-LC-MS/MS screening tool for raw material control, export risk management and routine QC decision-making.



KIT CONTENTS
-SmarKIT Glyphosate Rapid Test (40/50 tests /kit)
-PBST Buffer (1 bottle/kit, 30ml)
-Buffer A (1 bottle/kit, 15ml)
-Packing Insert (1 set /kit)

TEST PROCEDURE
Read the entire procedure carefully before performing any test.
Keep the test kit and reagent at room temperature(20℃~30℃) before testing.

1. Prepare samples according to chapter 7 (Sample preparations).
2. Remove the Glyphosate Rapid Test from sealed pouch.
3. Hold the dropper vertically and transfer 3 full drops(around 100µL) of solution to the specimen well (S) and then start the timer.
4. Wait for red bands to appear. The result should be read in approximately 3-5 minutes. Do not interpret results after 5 minutes.

Reading results
Negative:
The Test Line (T) is the same as or darker than the Control Line (C). It is negative.
POSITIVE:
The Test Line (T) is lighter than the Control Line (C), or there is no Test Line. It is positive.

INVALID: Reference Line fails to appear.
Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result.
Review the procedure and repeat the test with a new test kit. Stop using the test kit immediately if the problem is not solved and contact your local distributor.
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2026 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号