Login    Join free Add to favorites    中文
Home >Products> Reagents >ELISA / Diagnostic Kits> Aflatoxin Quantitative Rapid Test Kit & Analyzer | EU Standard, Validated Against LC-MS/MS
Aflatoxin Quantitative Rapid Test Kit & Analyzer | EU Standard, Validated Against LC-MS/MS
Aflatoxin Quantitative Rapid Test Kit & Analyzer | EU Standard, Validated Against LC-MS/MS
Origin of place China
Model
Supplier Nankai Biotech Co., Ltd.
Price
Hits 65
Updated 3/2/2026
  • Product Detail
  • Company Profile
The Aflatoxin Quantitative Rapid Test Kit & Analyzer is an integrated rapid testing system combining professional test strips with a dedicated reading instrument for aflatoxin detection.
 
It is specifically developed for large-scale, on-site screening and routine quality control of commodities commonly used in Europe and Africa, including but not limited to:
• Corn
• Wheat
• Maize
• Rice
• Peanuts
• Animal feed
• Selected herbal materials
 
The system enables fast decision-making at grain silos, feed mills, warehouses, and inspection points without reliance on centralized laboratories.
 
Key compliance & performance highlights:
• Fully compliant with EU Maximum Residue Limits (MRL)
• Validated against LC-MS/MS reference methods
• Strong correlation with laboratory results
• Suitable for both quantitative and qualitative analysis
• Proven through long-term, high-volume global use
 

 
Key Advantages — What Makes This System Different
 
✅ On-Site, Large-Scale Screening Capability
• Results in 5–10 minutes
• Designed for batch screening at:
• Grain silos
• Feed mills
• Warehouses
• Ports & export inspection points
• Ideal for high-throughput decision-making
 

 
✅ EU Standard & LC-MS/MS–Validated Performance
• Fully aligned with EU MRL requirements for aflatoxin
• Performance validated and benchmarked against LC-MS/MS
• Reliable for regulatory screening, internal QC, and export compliance
 

 
✅ Quantitative & Qualitative Detection
• Supports quantitative result reading via analyzer
• Enables risk grading, not just pass/fail decisions
• Suitable for on-site screening + laboratory confirmation workflow
 

 
✅ Proven by Tens of Millions of Tests
• 20+ years of rapid test manufacturing expertise
• Tens of millions of batches tested worldwide
• Selected for Olympic Games, Asian Games, and large-scale food safety programs
• Long-term validation far beyond most manufacturers
 
 
✅ Cost-Effective & Easy to Operate
• No complex laboratory instruments required
• Minimal training needed
• Significantly reduces routine LC-MS/MS testing frequency and cost
 
 
⭐ Brand Trust Endorsement
 
Proven Beyond the Laboratory — Trusted by the Real World
 
Unlike many suppliers whose aflatoxin testing equipment is only validated under limited laboratory conditions or no validation, our Aflatoxin Quantitative Rapid Test System has been proven through tens of millions of real-world tests across global grain, feed, and food safety systems.
 
With over 20 years of dedicated rapid test manufacturing experience, our solutions have been selected for national food safety programs and major international sporting events, including the Olympic Games and Asian Games — environments where accuracy, stability, and zero tolerance for error are mandatory.
 
This level of long-term, high-volume validation clearly distinguishes us from ordinary manufacturers.
We are not just providing a detector or analyzer — we are delivering a globally proven food safety solution.
 

 
 Application Fields
•  Grain & cereal screening (corn, wheat, maize, rice, peanuts)
•  Feed mills & raw material intake inspection
•  Export & import quality control
•  Laboratories & third-party testing centers
•  Government & large-scale food safety programs
 

 
 General Technical Specifications
 
Item Description
Detection Type Quantitative & Qualitative
Target Aflatoxin
Detection Time 3–5 minutes
Performance Validated against LC-MS/MS reference methods
Compliance EU MRL, CE, ISO
Sample Types Grains, feed, herbs
Storage 4–30°C
Shelf Life 15 months
 
 
 
STORAGE AND STABILITY
Store at room temperature(4-30℃).
DO NOT FREEZE or use beyond the expiration date.
The shelf life is 15 months.

KIT CONTENTS
-SmarKIT Total Aflatoxin Rapid Test (40/50 tests /kit)
-Plastic dropper (40/50 pieces /kit)
-PBST Buffer (1 bottle/kit, 30ml)
-Buffer A (1 bottle/kit, 15ml)
-Packing Insert (1 set /kit)

TEST PROCEDURE
Read the entire procedure carefully before performing any test.
Keep the test kit and reagent at room temperature(20℃~30℃) before testing.

1. Prepare samples according to chapter 7 (Sample preparations).
2. Remove the Total Aflatoxin Rapid Test from sealed pouch.
3. Hold the dropper vertically and transfer 3 full drops(around 100µL) of solution to the specimen well (S) and then start the timer.
4. Wait for red bands to appear. The result should be read in approximately 3-5 minutes. Do not interpret results after 5 minutes.

Reading results
Negative:
The Test Line (T) is the same as or darker than the Control Line (C). It is negative.
POSITIVE:
The Test Line (T) is lighter than the Control Line (C), or there is no Test Line. It is positive.

INVALID: Reference Line fails to appear.
Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for an invalid result.
Review the procedure and repeat the test with a new test kit. Stop using the test kit immediately if the problem is not solved and contact your local distributor.
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2026 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号