MAS-C

● Activate the column with acetonitrile.
● Add the plasma sample into the above tube
● Add eluent and wait for 3-4 min for precipitation
● Apply vacuum to get the solution through the column and    collect the  solution
.● Add more solution for elution, collect the eluent and combine collected solution, evaporate solvents and reconstitute the   sample with mobile phase, for HPLC or LC-MS analysis.
Characteristic of the Method
● In conventional SPE method, interference matrices are adsorbed and then target compounds eluted, but the MAS are only to adsorb impurities
● MAS employ the sorbent modified with different functional groups that could,  simultaneously remove a variety of impurities in one step.
● MAS has good separation ability and selectivity for the proteins, peptides, amino  acids, phospholipids, and such biological interference matrix.
● By choosing suitable conditions (solvent and pH), most of the biological interference can be removed, and to ensure strong water-soluble substances tested with more  than 70% recovery rate, also for further separation of LC-MS detection.
 
Ordering Info 
Production
Spec.
Application
Package
Part No.
MAS SPE cartridge
1mL
SPE cartridges, used for basic and neutral substances extraction in Plasma and biological samples
100
MSC-B-0301
1mL
100
MSC-B-0601
1mL
SPE cartridges, used for acid substances extraction in Plasma and biological samples
100
MSC-A-0301
1mL
100
MSC-A-0601
MAS 96 well plate
30mg/2ml/well
96 well plate, used for basic and neutral substances extraction in plasma and biological samples.
2
MS-B-0302W
30mg/2ml/well
96 well plate, used for basic and neutral substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation)
2
MS-B-0302W
30mg/2ml/well
96 well plate, used for acid substances extraction in plasma and biological samples.
2
MS-A-0302W
30mg/2ml/well
96 well plate, used for acid substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation).
2
MS-A-0302FW
30mg/2ml/well
96 well plate, used for weak acid substances extraction in plasma and biological samples.
2
MS-WA-0302-W
30mg/2ml/well
96 well plate, used for weak acid substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation)
2
MS-WA-0302-FW
Applications
The most convenient and general approach for 
Propranolol in the Serum with MAS-LC-MS
Result Contrast from Detection on the Amlodipine in the Serum with MAS-SPE and PPT and SPE Respectiv
MAS-C Protein Precipitate Columns and SLE on the Drug Metabolism Analysis in the Sample of Serum
Simultaneous Detection of Glipizide and Glibenclamide with MAS 
 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号