Login    Join free Add to favorites    中文
Home >Products> Sample Processing >Pipettors > P Series Multichannel Volume Micropipettes
P Series Multichannel Volume Micropipettes
P Series Multichannel Volume Micropipettes
Origin of place China
Model
Supplier TOPSCIEN INSTRUMENT (NING BO) CO.,LTD
Price
Hits 1684
Updated 8/24/2015
  • Product Detail
  • Company Profile

Easy Handling 
A particular advantage of the new multichannel pipette is the easy operation , e.g., when performing serial pipetting of immunological assays , while making serial dilutions or when filling 96-well plates for cell cultures . Use the Innovative material will be more lighter . Pipetting easy and convenient
Reduce the risk for hands injury when repetitive pipetting .
It can be operated comfortably whether large hands or small hands , 
The ergonomiCelly finger rest takes the load off the hand , not need to grip the pipette tightly , so the pipetting operations can be completed with the fatigue . True one-hand operated
The one hand can be change the volume and fix the volume easyly and conveniently . 
The large pipetting button will be saved pipetting strength .
Pisto n corrosion proof

Lightweight-Accurate-low force
The piston-operated Micropipettes provides maximum versatility and optimum quality over the entire volume range.
There are 5 different volume 8 and 12chennels micropipette which the volume cover 0.5-300ul

Features : 
The TOPSCIEN multichannel Micropipette have the Iight weigh,operated with light pipetting strength and easily and conveniently . 
High chemical and UV resistance 
Fully autoclavable 
Rotating dispensing head for optimal pipetting Convenience . 
Due to the optimized standard design for the tip cone which it can be compatible with a wide range band of tips

A central pipetting button, the one-handed operation, precise 4-position volume settings and a volume display that can be easily read by both right- and left-handed operators are only a few examples of the attention to detail in the design of the TOPSCIEN Variable Volume Micropipette


P Series Variable Volume 8 Channel Micropipette (121℃ autoclavable )

Cat.No
Code. No.
 
Volume  
Volume range
μl
Volume step
μl
A*≤±%
CV*≤%
Increment
μl
Type of tips
μl
8011260
TP8D10H
0.5-10
10/5/1
1.6/2/8
1.0/2/6
0.01
20
8011261
TP8D50H
5-50
50/25/5
0.8/1.4/6
0.4/0.8/3
0.05
200
8011262
TP8D100H
10-100
100/50/10
0.8/1.4/4
0.3/0.6/2
0.1
200/300
8011263
TP8D200H
20-200
200/100 /20
0.8/1.4/4
0.3/0.6/1.5
0.2
200/300
8011264
TP8D300H
30-300
300/150/30
0.6/1.2/3
0.3/0.6/1.5
0.3
300


P Series Variable Volume 8 Channel Micropipette( Ejector 121℃ autoclavable)

Cat.No
Code. No.
 
Volume 
Volume range
μl
Volume step
μl
A*≤±%
CV*≤%
Increment
μl
Type of tips
μl
8011270
TP8D10
0.5-10
10/5/1
1.6/2/8
1.0/2/6
0.01
20
8011271
TP8D50
5-50
50/25/5
0.8/1.4/6
0.4/0.8/3
0.05
200
8011272
TP8D100
10-100
100/50/10
0.8/1.4/4
0.3/0.6/2
0.1
200/300
8011273
TP8D200
20-200
200/100 /20
0.8/1.4/4
0.3/0.6/1.5
0.2
200/300
8011274
TP8D300
30-300
300/150/30
0.6/1.2/3
0.3/0.6/1.5
0.3
300


P Series Variable Volume 12 Channel Micropipette (121℃ autoclavable ) 

Cat.No
Code. No.
 
Volume  
Volume range
μl
Volume step
μl
A*≤±%
CV*≤%
Increment
μl
Type of tips
μl
8011280
TP12D10H
0.5-10
10/5/1
1.6/2/8
1.0/2/6
0.01
20
8011281
TP12D50H
5-50
50/25/5
0.8/1.4/6
0.4/0.8/3
0.05
200
8011282
TP12D100H
10-100
100/50/10
0.8/1.4/4
0.3/0.6/2
0.1
200/300
8011283
TP12D200H
20-200
200/100 /20
0.8/1.4/4
0.3/0.6/1.5
0.2
200/300
8011284
TP12D300H
30-300
300/150/30
0.6/1.2/3
0.3/0.6/1.5
0.3
300


P Series Variable Volume 12 Channel Micropipette( Ejector 121℃ autoclavable)

Cat.No
Code. No.
 
Volume 
Volume range
μl
Volume step
μl
A*≤±%
CV*≤%
Increment
μl
Type of tips
μl
8011290
TP12D10
0.5-10
10/5/1
1.6/2/8
1.0/2/6
0.01
20
8011291
TP12D50
5-50
50/25/5
0.8/1.4/6
0.4/0.8/3
0.05
200
8011292
TP12D100
10-100
100/50/10
0.8/1.4/4
0.3/0.6/2
0.1
200/300
8011293
TP12D200
20-200
200/100 /20
0.8/1.4/4
0.3/0.6/1.5
0.2
200/300
8011294
TP12D300
30-300
300/150/30
0.6/1.2/3
0.3/0.6/1.5
0.3
300

Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号