Login    Join free Add to favorites    中文
Home >Products> Lab Water | Ultrafilters | Concentration | Reaction >Ultrafilters> CSJM-S Series Ultrapure Water System
Lab Water | Ultrafilters | Concentration | Reaction:  Lab Water   Ultrafilters   Concentration / Rotary Evaporators   Reaction Kettle / Glass Reactor  
CSJM-S Series Ultrapure Water System
CSJM-S Series Ultrapure Water System
Origin of place China
Model CSJM -S15 /S30/S15UF/S30UF/S15UV/S30UV/S15UVF/S30UVF
Supplier Qingdao Haier Medical Product Division
Price
Hits 3272
Updated 5/3/2025
  • Product Detail
  • Company Profile

1, Specification

 

Model Features

Standard

Model(Normal)

CSJM-S15

Model(High Capacity)

CSJM-S30

Feed water requirements*

Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm )

Process Flow**

PF+KDF+AC+RO+AC+DI+TF

Resistivity

18.2 mΩ•cm (25°C)

Heavy Metal Ions

<0.1 ppb

Total organic carbon

<10 ppb

Bacteria

<0.1 cfu/ml

Pyrogen(Endotoxin)

N/A

Particulates (>0.2μm)

N/A

RNases

N/A

DNases

N/A

Ion rejection rate

96%-99% (with new RO membranes)

Rejection of Organic contaminants

>99% , when MW>200 Dalton

Rejection of Particulates and Bacteria

>99%

Water production rate (25°C) ***

S15: 15 L/h, S30: 30 L/h

Instant Dispensing Rate

2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate)

Water Outlets

Two: Reverse Osmosis purified water, and Ultra-pure water

Dimensions

W*D*H: 500*360*540 mm, 25 kg

Power supply/Power

220V/50Hz, 120W

Standard system configuration

Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories

 

Model Features

Pyrogen-Removal

Model (Normal)

CSJM-S15UF

Model (High Capacity)

CSJM-S30UF

Feed water requirements*

Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm )

Process Flow**

PF+KDF+AC+RO+AC+DI+UF+TF

Resistivity

18.2 mΩ•cm (25°C)

Heavy Metal Ions

<0.1 ppb

Total organic carbon

<10 ppb

Bacteria

<0.1 cfu/ml

Pyrogen(Endotoxin)

<0.01 ng/ml

Particulates (>0.2μm)

<1/ml

RNases

<0.01 ng/ml

DNases

<4 pg/μl

Ion rejection rate

96%-99% (with new RO membranes)

Rejection of Organic contaminants

>99% , when MW>200 Dalton

Rejection of Particulates and Bacteria

>99%

Water production rate (25°C) ***

S15: 15 L/h, S30: 30 L/h

Instant Dispensing Rate

2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate)

Water Outlets

Two: Reverse Osmosis purified water, and Ultra-pure water

Dimensions

W*D*H: 500*360*540 mm, 25 kg

Power supply/Power

220V/50Hz, 120W

Standard system configuration

Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories

 

Model Features

Low Levels of Organics

Model(Normal)

CSJM-S15UV

Model(High Capacity)

CSJM-S30UV

Feed water requirements*

Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener recommend when TDS>200 ppm )

Process Flow**

PF+KDF+AC+RO+UV+AC+DI+TF

Resistivity

18.2 mΩ•cm (25°C)

Heavy Metal Ions

<0.1 ppb

Total organic carbon

<3 ppb

Bacteria

<0.1 cfu/ml

Pyrogen(Endotoxin)

N/A

Particulates (>0.2μm)

N/A

RNases

N/A

DNases

N/A

Ion rejection rate

96%-99% (with new RO membranes)

Rejection of Organic contaminants

>99% , when MW>200 Dalton

Rejection of Particulates and Bacteria

>99%

Water production rate (25°C) ***

S15: 15 L/h, S30: 30 L/h

Instant Dispensing Rate

2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate)

Water Outlets

Two: Reverse Osmosis purified water, and Ultra-pure water

Dimensions

W*D*H: 500*360*540 mm, 25 kg

Power supply/Power

220V/50Hz, 120W

Standard system configuration

Water Purification Unit (with one set of purification modules), 15 L pressure tank,

 accessories

 

Model Features

Hybird

Model(Normal)

CSJM-S15UVF

Model(High Capacity)

CSJM-S30UVF

Feed water requirements*

Tap water: TDS<200 ppm, 5-45 °C, 1.0-4.0 Kgf/cm2 (Additional Water softener 

recommend when TDS>200 ppm )

Process Flow**

PF+KDF+AC+RO+UV+AC+DI+UF+TF

Resistivity

18.2 mΩ•cm (25°C)

Heavy Metal Ions

<0.1 ppb

Total organic carbon

<3 ppb

Bacteria

<0.1 cfu/ml

Pyrogen(Endotoxin)

<0.01 ng/ml

Particulates (>0.2μm)

<1/ml

RNases

<0.01 ng/ml

DNases

<4 pg/μl

Ion rejection rate

96%-99% (with new RO membranes)

Rejection of Organic contaminants

>99% , when MW>200 Dalton

Rejection of Particulates and Bacteria

>99%

Water production rate (25°C) ***

S15: 15 L/h, S30: 30 L/h

Instant Dispensing Rate

2.0 L/min (Pressure tank required, models with UF installed have lower dispensing rate)

Water Outlets

Two: Reverse Osmosis purified water, and Ultra-pure water

Dimensions

W*D*H: 500*360*540 mm, 25 kg

Power supply/Power

220V/50Hz, 120W

Standard system configuration

Water Purification Unit (with one set of purification modules), 15 L pressure tank, accessories

 

2, Features

 

Fed tap water,conveniently produces 18.2 mΩ·cm ultrapure water at 15-30L/min.Water quality meets or exceeds the standards of L/min.Water quality meets or exceeds the standards of analytical applications

 

Applications

1) HPLC/GC-MS/ICP-AES

2) TOC analyses,IC

3) Molecular Biology,Microbiology

4) Preparation of cells and culture media

5) ICP-MS/AAS/GF-AAS

6) Mammalian Cell Culture

7) PCR applications and analyses

8) Ultra-trace,trace mineral,trace organics analysis

9) Electrochemical

10) DNA sequence analysis

11) Electrophoresis,gel analysis

12) Monoclonal Antibody Production

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号