Features:
※ Application : Water and wastewater treatment, drinking water and surface water monitoring, chemical process, recycling water,and scrubber.
※ 9 0-degree of the optical detection principle.
※ Color and bubbles without interference,build in self-clean system.
※ 5 -points calibration, single-point calibration can be analyzed based on laboratory or field.
※ Stainless steel housing and hard to scratch lenses.
※ Panel or Wall mounts Enclosures, NEMA4 X, IP6 5 water proof, dust proof.
※ Providing grounding function,prevent sample charged interference.
※ Large LCD with Auto/Manual background illumination screen.
※ Password protections prevent unauthorized of setting.
※ RS-48 5 interface communication (AE-TO-3, AE-TO-4 ).
※ Scaleable isolate d output: 0/4 ~20mA.
※ Two separate mechanical relays for high and low (HH/HL/LL) set points.
※ Separately adjustable high and low set-point hysteresis (dead bands) prevent chattering of relays around the set point.
※ The third mechanical relays for electrode self-cleaning or alarm.
Technical Specifications:
	
		
			| Model | AE-TO-1 | AE-TO-2 | AE-TO-3 | AE-TO-4 | 
		
			| Range | Turbidity / Suspended Solid(SS) / (MLSS) | 
		
			| Turbidity Unit | NTU,FTU,FNU | 
		
			| SS Unit | ppm, mg/L | 
		
			| MLSS Unit | g/L | 
		
			| Turbidity Range | 0.00-20.00,20.0-100.0 / 0.0-200.0,200-500 / 0-3000 NTU (depends on sensor) | 
		
			| SS Range | 0~1000 mg/L | 
		
			| MLSS Range | 0.0-50.0 g/L | 
		
			| Resolution | Auto (0.01,0.1,1) | 
		
			| Analog Output | 2 sets 0/4 ~ 20mA | 1 set 0/4〜20mA | 
		
			| Serial Interface | - | RS-485 | 
		
			| Relay Specification | 2SPST/240VAC0.5A | 
		
			| Frequency of Cleaning Time | ON 0-9999 sec / OFF 0-999.9 hours | 
		
			| Operation Temperature | 0~50°C | 
		
			| Power Supply | 100~240VAC±10% , 50/60Hz | 20-30VDC | 100~240VAC±10% , 50/60Hz | 20-30VDC | 
		
			| Size / Weight | 144mmxl44mmxll5mm / 800g | 
		
			| Installation Size | 138mmxl38mm | 
	
Pls kindly note me via E-mail:  dvp@aelabcn.com
 
bio-equip.cn