     A rapid test for the qualitative detection of Chlamydia antigen in female cervical swab, male urethral swab and 

    male urine specimens. For professional in vitro diagnostic use only. 
     
    Chlamydia Antigen INTENDED USE 
    The Chlamydia Rapid Test Device (Swab/Urine) is a rapid chromatographic immunoassay for the qualitative 
    detection of Chlamydia trachomatis in female cervical swab, male urethral swab and male urine specimens to 
    aid in the diagnosis of Chlamydia infection. 
     
    Chlamydia Antigen SUMMARY 
    Chlamydia trachomatis is the most common cause of sexually transmitted venereal infection in the world. It is 
    composed of elementary bodies (the infectious form) and reticulate or inclusions bodies (the replicating form). 
    Chlamydia trachomatis has both a high prevalence and asymptomatic carriage rate, with frequent serious 
    complications in both women and neonates. Complications of Chlamydia infection in women include cervicitis, 
    urethritis, endometritis, pelvic inflammatory disease (PID) and increased incidence of ectopic pregnancy and 
    infertility.1 Vertical transmission ofthe disease during parturition from mother to neonatecan result in 
    inclusion conjunctivitis pneumonia. In men, complications of Chlamydia infection include urethritis and 
    epididymitis. At least 40% of the nongonococcal urethritis cases are associated with Chlamydia infection. 
    Approximately 70% of women with endocervical infections and up to 50% of men with urethral infections are 
    asymptomatic. 
    Traditionally, Chlamydia infection has been diagnosed by detection of Chlamydia inclusions in tissue culture 
    cells. Culture method is the most sensitive and specific laboratory method, but it is labor intensive, expensive, 
    long (48-72 hours) and not routinely available in most institutions. 
    The Chlamydia Rapid Test Device (Swab/Urine) is a rapid test to qualitatively detect the Chlamydia antigen 
    from female cervical swab, male urethral swab and male urine specimens, providing results in 10 minutes. 
    The test utilizes antibody specific for Chlamydia to selectively detect Chlamydia antigen from female cervical 
    swab, male urethral swab and male urine specimens. 
     
    Chlamydia Antigen PRINCIPLE 
    The Chlamydia Rapid Test Device (Swab/Urine) is a qualitative, lateral flow immunoassay for the detection of 
    Chlamydia antigen from female cervical swab, male urethral swab and male urine specimens. In this test, 
    antibody specific to the Chlamydia antigen is coated on the test line region of the test. During testing, the 
    extracted antigen solution reacts with an antibody to Chlamydia that is coated onto particles. The mixture 
    migrates up to react with the antibody to Chlamydia on the membrane and generate a colored line in the test 
    line region. The presence of this colored line in the test line region indicates a positive result, while its 
    absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the 
    control line region indicating that proper volume of specimen has been added and membrane wicking has 
    occurred. 
    Chlamydia Antigen REAGENTS 
    The test device contains Chlamydia antibody coated particles and Chlamydia antigen coated on the 
    membrane. 
     
    Chlamydia Antigen PRECAUTIONS 
    • For professional in vitro diagnostic use only. Do not use after expiration date. 
    • The test device should remain in the sealed pouch until use. 
    • Do not eat, drink or smoke in the area where the specimens or kits are handled. 
    • Do not use test if pouch is damaged. 
    • Handle all specimens as if they contain infectious agents. Observe established precautions against 
    microbiological hazards throughout testing and follow standard procedures for proper disposal of specimens. 
    • Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens 
    are being tested. 
    • Humidity and temperature can adversely affect results. 
    • Use only sterile swabs to obtain endocervical specimens. 
    Chlamydia Antigen DIRECTIONS FOR USE 
     
    Allow the test device, specimen, reagents, and/or controls to reach room temperature (15-30°C) prior to 
    testing. 
    1. Remove the test device from the sealed foil pouch and use it as soon as possible. Best results will be 
    obtained if the test is performed immediately after opening the foil pouch. 
    2. Extract the Chlamydia antigen according to the specimen type. 
    For Female Cervical or Male Urethral Swab Specimens: 
    • Hold the Reagent A bottle vertically and add 5 full drops of Reagent A (approximately 300 µL) to the 
    extraction tube. Reagent A is colorless. Immediately insert the swab, compress the bottom of the tube and 
    rotate the swab 15 times. Let stand for 2 minutes. 
    • Fill the quantitative pipette for Reagent B up to the marked line (approximately 220 µL) then add the 
    Reagent B to the extraction tube. The solution will turn cloudy. Compress the bottom of tube and rotate the 
    swab 15 times until the solution turns toa clear color with a slight green or blue tint. If the swab is bloody, the 
    color will turn yellow or brown. Let stand for 1 minute. 
    •Press the swab against the side of the tube and withdraw the swab while squeezing the tube. Keep as 
    much liquid in the tube as possible. Fit the dropper tip on top of the extraction tube.
    For Male Urine Specimens: 
    •Fill the quantitative pipette for Reagent B to the marked line (approximately 220 µL) then add the Reagent 
    B to the urine pellet in the centrifuge tube, then draw the liquid up and down with a pipette to vigorously mix 
    until the suspension is homogeneous. 
    • Transfer all the solution in the centrifuge tube to an extraction tube. Let stand for 1 minute. Hold the 
    Reagent A bottle upright and add 5 full drops of Reagent A (approximately 300 µL) then add to the extraction 
    tube. Vortex or tap the bottom of the tube to mix the solution. Let stand for 2 minutes. 
    •Fit the dropper tip on top of the extraction tube. 
    3. Place the test device on a clean and level surface. Add 3 full drops of the extracted solution (approximately 
    100 µL) to the specimen well (S) of the test device, andstart the timer. Avoid trapping air bubbles in the 
    specimen well (S). 
    4. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 20 minutes. 
     
    INTERPRETATION OF RESULTS (Please refer to the illustration above) 
    POSITIVE:Two distinct colored lines appear. One line should be in the control line region (C) and another 
    line should be in the test line region (T). 
    NOTE: The shade of color in the test line region (T) may vary, but it should be considered positive whenever 
    there is even a faint colored line. 
    NEGATIVE:One colored line appears in the control line region (C). No apparent colored line appears in the 
    test line region (T). 
    INVALID: Control line fails to appear. Insufficient sample volume or incorrect procedural techniques are the 
    most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If 
    the problem persists, discontinue using the test kit immediately and contact your local distributor. 
    Relative Sensitivity: 88.5% (76.6%-95.6%) Relative Specificity: 96.7% (90.6%-99.3%) 
    Accuracy: 93.7% (88.3%-97.1%) 95% Confidence Interval 

    Contact  Rebecca Yan 

    Skype: span.biotech

    Email: rebecca@spanbio.com

    Tel:  +86(755)89589611

    Fax: +86(755)89580096

    Web:

    www.spanbiotech.com

    bio-equip.cn
    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
    Efficiently structured to provide lasting and economic health care solutions with export ready goods, our main products cover the following immunodiagnostic rapid test kits:
    Rapid Tests for Human Use :
    1) Fertility: Pregnancy HCG, ovulation LH, menopause FSH
    2) Infectious diseases: Hepatitis B, HCV, HIV
    3) Drug abuse: AMP, BAR, BZO, COC, mAMP, MOP, MTD, OPI, PCP, TCA, THC
    4) Tumor markers: CEA, PSA, AFP, FOB
    5) STDs(Sexually Transmitted Diseases): Gonorrhea, syphilis, chlamydia
    6) New products: Malaria, H. Pylori, Multi-Hepatis B Panel (HBsAg, Anti-HBs, HBeAg, Anti-HBe, Anti-HBc), Blood Glucose Test, Multi-drug of Abuse Panel, Avian (Bird) Flu Rapid Test, etc.
    Rapid Tests for Veterinary :
    1) Bovine: Cow Pregnancy , Cow Ovulation, Bovine Brucella, Bovine Tuberculosis ,Food and Mouth Disease NSP Ab Test
    2) Canine: Canine Distemper, Canine Parvovirus, Canine Coronavirus
    3) Feline : Feline Leukemia Virus Ag Rapid Test ,Feline Panleucopenia Virus Ag Test,Feline Immunodeficiency Virus Ab Test
    Rapid Tests for Food Safety :
    1)For Antibiotics Residue : Nitrofurans (AOZ,AMOZ, AHD, SEM), Streptomycin , Sulfonamides , Chloramphenicol , Quinolone , Beta-Lactam&Tetracycline Combo (2 in 1), β-Lactams & Streptomycin & Chloramphenicol & Tetracyclines Combo (4 in 1), Beta-Lactam, Tetracycline test
    2) For Beta-Agonist Residue : Ractopamine, Clenbuterol ,Salbutamol
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.