Features
1.Frequency: 40Khz
2.Temperature: 0 to 65°C
3.Ultrasonic power adjustable from 20-100%
4.Timer: 1-99 infinite loop
5.Sweep frequency capability
6.Soundproof design, more quiet
7. Safe and steady PCB
8.Industrial grade IC with powerful ultrasonic transducer
9.Working frequency LCD display
10. Working temperature LCD display
11. Working time LCD display
12. Memory setting function
13. The whole machine made of stainless steel
14. spray-paint in size 15L/20L/30L for choice
Application
Use in hospital to cleaning ,sterilize and dry the scalpel, tweezers, hemostatic forceps、endoscopic biopsy forceps, needles, various size syringe, tube, sheet glass, dressing bowl, all kinds of dishes, round barrel, pressure apparatus and radioactive, polluting, high-volume, nobleness degree medical equipment cleaning, sanitizing etc. The necessary equipment for operating, supply room and disinfection center of hospital , R&D institution, laboratory.
Gynaecology instruments:
Apart from blood, other endogenic fluids also dry quickly on specula. It has been noted that they are very difficult to remove manually. Therefore, instruments and accessories from gynaecology should principally be prepared with especially efficient mechanical cleaning procedures.
Certain mucous disinfectants fix proteins and cause corrosion. These can be replaced with halide-free and non-fixing preparations.
Orthopaedics instruments:
Bone cement is very difficult to remove and often only completely by means of an alkaline RDG (cleaning and disinfectant devices) procedure after drying.
Bone cement must be wiped off the instruments immediately after use in the operation theatre, for example, bone rasps can be freed of splinters in an ultrasound bath.These splinters can be dragged into the machine clogging up the jet spray arms and thus reduce the rinsing pressure. Particular attention should be shown to intramedullary reamers and screws. The manufacturers generally provide important advice in the operating instructions according to DIN EN ISO 17664, about how the overall quality of the decontamination can be ensured by a targeted, short manual clean.
ENT instruments:
In the ENT area, ointments often make reprocessing more difficult. They should be wiped off immediately and as completely as possible after the application in the operating theatre.
MIS instruments:
Despite receptacle containers, a manual preparation – e.g. with special brushes – is often required. Instruments which cannot be dismantled or devices without rinsing connections cannot be safely decontaminated according to today’s standards and should not be used.
Mono- and bipolar instruments:
These instruments routinely adhere with coagulated blood and tissue which cannot be removed in a mechanical preparation. Soaking the tips in 3 % hydrogen peroxide solution, or very strong alkaline prodcuts is recommended for manual decontamination. Where necessary the tips should be wiped to remove excess product.
Eye instruments:
Ophthalmic surgical instruments are often very sensitive due to their filigree structure. Thus, a manual clean is not possible in most of the cases.According to the latest legal requirements (Guideline of the Robert Koch Institute and ISO 17664),the manufacturer of these products must define at least one automatic and validated procedure for their decontamination.
The procedure must include, among others, details on validated processes for safe cleaning, disinfection and sterilisation. Due to the sensitivity of the eyes, it is vital to make sure, e.g. by measuring chemical parameters, that no process chemicals have remained on the tools to be prepared.
The ideal situation for CSSD would be to work closely with the operating theatres. This cooperation ensures that everyone is involved and understands which measures are used for the “drop” in order to aid the next steps of decontamination. The instructions and recommendations of the instrument manufacturer should strictly be observed.
Specifications
KMH1-360W9152 15 480×500×530 355×325×150 360 300
KMH1-720U9202 20 560×500×530 530×325×150 600 500
KMH1-1100U9302 30 560×500×530 530×325×200 720 500
KMH1-1200U9502 50 750×550×860 600×400×210 1080 1000
KMH1-1440U9722 72 810×600×860 660×450×240 1440 1000
KMH1-1680U9962 96 850×630×860 700×480×300 1800 1500
KMH1-2160U0122 120 850×630×860 700×480×350 2160 2000
KMH1-1100W0122 144 850×650×910 700×500×400 2400 3000
KMH1-1440W0122 200 900×750×960 750×600×450 2880 4000