Home >Products> Physicial & Chemical Analysis >Other Physicial & Chemical Analysis> gas flowing principle determine specific surface area by F-Sorb 1400CE
Physicial & Chemical Analysis:  PH Meters / Conductance   Other Physicial & Chemical Analysis  
gas flowing principle determine specific surface area by F-Sorb 1400CE
gas flowing principle determine specific surface area by F-Sorb 1400CE
Place of Origin:
China
Brand:
Gold APP Instruments
Model:
F-Sorb 1400CE
Price:
USD 1
Hits:
1961 
Updated:
2/4/2025
  • Product Detail
  • Company Profile

    F-Sorb 1400CE surface area analyzer introduction

     
    F-Sorb X400CE series surface area and porosimetry analysers are new generation instruments which were researched and developed by Gold APP Instruments and China weapons institute. Gold APP Instruments is the ONLY one domestic manufacturer can produce no user intervention, fully-auto and highly intelligent analyzers which can match international standards and trends. Innumerable independently patented techs make Gold APP instruments enjoy great popularity at home and abroad. A high level of precision and resolution, complicity of operation, speed, compact size, and their stability guarantee our analyzers equally appropriate to industry quality control, institutes, universities and laboratories. The weapons system’s high demands and imported parts with original packaging had greatly improved instruments’ reliability and life. The high cost performance of F-Sorb X400CE series analyzers easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ demands.
     
    F-Sorb 1400CE adopts speedy and efficient continuous flowing nitrogen adsorption principle, is a bosom friend for contrast reference materials method analysis which calculates surface area by comparing with reference materials’ (RM) adsorption/desorption isotherm. No need of gas adsorption/desorption amount dosing, suitable for those samples have similar adsorption performance with RM. F-Sorb 1400CE mainly be used for quality control of production field, quick speed is its primary and pleased advantage which makes it easily stay ahead of your competition.
     
     
     
    Measuring Method: contrast reference method by flowing gas (nitrogen) adsorption principle
    Measuring Ranges: 0.01 m2/g to no known upper limit (surface area)
    Accuracy: repeatability deviations ≤1%
    Sample Types: powders, particle, fiber, flakes and other species have similar adsorption performance with reference materials (RM)
    Sample Ports: 4 samples simultaneously
    Analysis Control: 7 inch high sensitive color touch screen with built-in PC operation system, providing USB linked keyboard and mouse; external PC is supportable by RS232 communication port for a larger operation interface; can be easily and quickly switched between two modes.
    Safety Cover: transparent cover can protect operators be hurt by liquid nitrogen splash; also can reduce liquid nitrogen volatilization, extend its testing time and save your cost; more important is the cover can isolate foreign environment influences to the analysis procedures, naturally, improve data stability and accuracy.
    Adsorbate: mixed He+N2 (4:1) with high purity
    Time: about 5 minutes for every P/Po point’s adsorption and desorption; analysis data will present automated by Gold APP Instruments softwareTM
    Pressure Required: atmospheric pressure, no need vacuum, save experiment time
    Data Acquisition: high precision and integration chip, minimal deviations, strong anti-interference ability
    Data Reduction: Windows®-base independent developed Gold APP Instruments softwareTM, perfect versatility, ease of use and multi-model data reduction reports.
    Operation System: multifunctional, fully automated, highly intelligent operation system
     
     
     
    Domestic first fully automated and intelligent analyzer; farewell to complex manual operation; minimal operator involvement; promote efficiency. 
     
    A. Structure Design
    1. Modern design with compact size can save your valuable bench space.
    2. Stainless steel manifold system obviously improves sealing performance, eliminates deviations caused by gas molecules permeation, no ageing for manifolds, increase reliability and prolong life.
     
    B. Control System
    1. Integrated multifunctional control system; motor screw rod lifting system ensures Dewar stability.
    2. Innovated balanced bridge circuit greatly improves signal voltage sensitivity, as well as realizes auto balance of signal zero drift.
    3. Fully-auto operation, minimal user involvement and work efficiency improved.
     
    C. Data Acquisition and Reduction
    1. High precision data acquisition and signal amplification, high integration A/D transformation system, strong anti-interference ability and high real time, can reduce environmental influence on analysis procedures.
    2. Independently innovated Windowscompatible software, versatile applications, flexible customer-tailor interface, ease of use; Self developed data reduction module can efficiently eliminate system deviations and improve accuracy.
    3. Customer made data reports, diversified forms module, convenient for data analyzing; powerful data archiving and searching capacity helps a lot for data management.
    4. Can be upgraded to F-Sorb 2400CE (supports mult-point BET).
     
     
     
    1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.
    2. Product quality control for powder species related corporations.
    3. Research institutes, universities for BET theory teaching.
    4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.
    5. Other researches concern surface area performance.
     
     
     
    visit www.goldapp.com.cn to get technical specifications and price for submitting tenders/ bids.
    bio-equip.cn
    Gold APP Instruments products cover BET Surface Area Analyzers, Pore Size/ Pore Volume Analyzers, Helium Pycnometer Density Analyzers, High Pressure Adsorption Analyzers, Chemical Adsorption Analyzers, Mercury Intrusion Porosimetry, Breakthrough Analyzers, Scanning Electron Microscope (SEM) Analyzers, Particle Size Analyzers, Zeta Potential Analyzers, Dynamic Image Size Analyzers, Thermal Analysis Analyzers, Dilatometers (DIL), Differential Scanning Calorimetry (DSC), Simultaneous Thermal Analyzers (STA), Thermogravimetric Analyzers (TGA), Precious Platinum Wires, Crucibles, Dishes etc. on for universities, institutes, govt labs etc.. Gold APP Instruments scientists have revolutionized measurement techniques and designed instrumentation to enable the accurate, precise, and reliable characterization of powder, porous, fiber, particle, solid, liquid etc. materials.

    Find more from web www.goldapp.com.cn
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.