LabTech UV-Vis spectrophotometer
UV Power Series
LabTech's UV Power UV-Vis spectrophotometers is the core of powerful UV-Visible systems for the diverse needs and suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, and multiple components.
read more>> |
|
UV9100 Series
LabTech's UV9100 series of UV-Vis spectrophotometers has been synonymous with excellence and high performance. The range is ideal for use as your own primary reference UV-Vis spectrophotometer in routine laboratories where reliability and ease of use are vital.
read more>> |
|
Bluestar & UV8100 Series
The BlueStar and UV8100 series spectrophotometer are the core of powerful UV-Visible systems for the diverse needs of analysts in routine QA/QC, research, and method development labs. The spectrophotometer offers – fast scanning, excellent sensitivity, exceptional ruggedness and reliability, minimum maintenance, and excellent optical performance.
read more>> |
|
LabTech UV Power Series UV-Vis spectrophotometer
LabTech's UV Power UV-Vis spectrophotometers are the core of powerful UV-Visible systems for the diverse needs and suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, and multiple component analysis.
It offers fast scanning, excellent sensitivity, exceptional ruggedness and reliability, minimum maintenance, and excellent optical performance. Five slit types, 0.5nm, 1nm, 2nm, 3nm, and 5nm, are available with a wavelength accuracy of ±0.3nm and less than 0.02 % stray light.
Features
- Excellent real double beams system.
- High integration 32Bit CPU guarantees high performance.
- Five kinds of slits: 0.5nm, 1nm, 2nm, 3nm, and 5nm.
- Quartz overcoating and sealed optics prevents exposure to corrosive environments.
- Light source records working time automatically and easily replaced by orientation design.
- Standard automatic six-coupled cell enormously shorten sample replacement time.
- Compact configuration and few movable parts improve reliability.
- Intellectual auto-checking function convenient for trouble shooting and maintenance.
- Standalone unit with powerful storage capacity - 32M.
- Optional standalone or PC control for diverse application.
- Stand mini-print flexible for printing.
- Streamline surface protects sample splashes into internal space.
The advantages of 32Bit CPU
With the development of industry and automation, there is an ever growing requirement for memory. LabTech applies international standard 32Bit CPU in UV Power UV-Vis spectrophotometer with compact circuit, stable performance, fast speed, and powerful operation to better serve our customers.
Technical parameters
Model |
UV Power |
UV 9500 |
Principle |
Double Beam |
Wavelength Range |
190-1100nm |
Optical System |
C-T, 35mm×35mm low stray light, H grating |
Bandwidth |
0.5nm/1nm/2nm/3nm/5nm adjustable |
Wavelength Accuracy |
±0.3nm |
Wavelength Repeatability |
±0.1 nm |
Absorption range |
-4~4Abs |
Photometric Accuracy |
±0.002A(0~0.5A), ±0.004A(0.5~1A) |
Photometric Repeatability |
≤0.001A(0~0.5A), ≤0.002A(0.5~1A) |
Scan Speed |
Adjustable |
Stray Light |
≤0.03% T |
Baseline straightness |
0.001A (200-1000nm) |
Drift |
≤0.0002A/h (500nm, 0A) |
Noise |
±0.0002A (500nm, P~P) |
Detector |
Double Si-Photodiode |
Light Source |
Halogen tungsten / Deuterium lamp |
Cell Holder |
Automatic six-coupled cell holder |
Display |
320×240 LCD |
PC |
Control Mode |
PC/Local |
PC |
Printer |
Optional HP Laserjet/Deskjet parallel printer or Mini-printer |
Power Supply |
220VAC±10% or 110VAC±10% |
LabTech UV9100 Series UV-Vis spectrophotometer
LabTech's UV9100 range of UV-Vis spectrophotometers has been synonymous with excellence and high performance. The range is ideal for use as your own primary reference UV-Vis spectrophotometer in routine laboratories where reliability and ease of use are vital.
Features
- Real double beams system
ensure that the sample and reference beam are symmetric, removing errors due to non uniformity of the optical system.
- Excellent core parts
grating, lightsource, and detector all come from famous suppliers.
- Variable slits
allow optimal control over data resolution. The spectral bandwidth can be set to 1, 2 nm or 0.5, 2 nm.
- Sealed optics
prevent exposure to corrosive environments.
- Quartz overcoating
protect the optics from the environment and allow cleaning without damage to their reflective surface.
- Automatic six-coupled cell
provide more flexibility in analysis.
- Stable performance
unaffected by room light. You can operate with the sample compartment open or closed, you won't notice any difference.
- User friendly software
Windows based software features a modular design which makes it easy to use.
Technical parameters
Model |
LabTech UV 9100 A |
LabTech UV 9100 B |
LabTech UV 9100 C |
LabTech UV 9100 D |
Optical principle |
double beam |
Wavelength range |
190 nm ~ 1100 nm |
Optical system |
C-T mode, holographic grating, 1200 / mm |
Spectrum bandwidth |
2nm |
1nm, 2nm |
0.5nm, 2nm |
0.5nm, 1nm,2nm,3nm,5nm |
Photometric method |
Transmittance, Absorbance, Energy |
Absorbance range |
-3 ~ 3Abs |
Wavelength Accuracy |
±0.3nm |
Wavelength Repeatability |
±0.1nm |
Photometric Accuracy |
±0.002A(0~0.5A), ±0.004A(0.5~1A), |
Photometric Repeatability |
≤0.001A(0~0.5A), ≤0.002A(0.5~1A), |
Stray Light |
≤0.05% T |
Baseline straightness |
0.001A |
Drift |
≤0.0002A/h |
Noise |
±0.0002A |
Scan speed |
adjustable |
Detector |
famous silicon photodiode |
Light source |
halogen tungsten lamp / deuterium lamp |
Cell ho |
automatic six-coupled cell bracket |
Display |
320 x 240 LCD |
Control mode |
Local and PC control |
Power source |
220V 50Hz |
Dimensions |
W500xD475xH 245mm |
Weight |
22Kg (net) |
LabTech BlueStar Series UV-Vis spectrophotometer
The BlueStar Series spectrophotometer is the core of powerful UV-Visible systems for the diverse needs of analysts in routine QA/QC, research, and method development labs. The spectrophotometer offers – fast scanning, excellent sensitivity, exceptional ruggedness and reliability, minimum maintenance, and excellent optical performance. A wavelength range of 190 to 1100 nm with a wavelength accuracy of ±0.3nm and less than 0.05 % stray light is standard.
Features
- Large LCD and friendly interface make the operation extremely easy.
- Optimized optics improves signal to noise ratio.
- Micro-stepping drive simplifies the mechanical complexity, reduces maintenance and improves the longevity.
- Advanced 32bit CPU guarantees sophisticated dada processing and graphic display.
- Lower price for daily routine analysis, as well as for more specialized applications.
Technical parameters
Model |
UV8500 |
BlueStar A |
BlueStar B |
UV8100A |
UV8100B |
UV8100C |
UV8100D |
Principle |
DoubleBeam |
Split Beam |
Wavelength Range |
190-1100nm |
Optical System |
C-T, H grating |
Bandwidth |
1nm |
2nm |
1nm,2nm |
2nm |
1nm,2nm |
0.5nm |
0.5,1,2,3,5nm |
Wavelength Accuracy |
±0.8nm |
±0.3nm |
Wavelength Repeatability |
±0.2nm |
±0.1nm |
Absorption range |
-3.0~3.0A |
Photometric Method |
%T, Abs, E |
Photometric Accuracy |
0.003Abs 0.3% T |
±0.002A (0~0.5A) ±0.004A(0.5~1.0A) |
Photometric Repeatability |
0.001Abs 0.1% T |
±0.001A (0~0.5A) ±0.002A(0.5~1.0A) |
Stray Light |
0.05% T |
Baseline straightness |
0.002A |
0.001A |
Scan Speed |
Adjustable |
Drift |
0.0005A/h |
0.0002A/h |
Noise |
±0.0005A |
±0.0002Abs |
Detector |
Si-Photodiode |
Light Source |
Halogen Tungsten / Deuterium Lamp |
Cell Holder |
Single cell holder |
Automatic six-coupled cell holder |
Control Mode |
Local and PC control |
Power Source |
220V 50Hz |
Dimensions |
W500xD475xH 245mm |
Weight |
22Kg (net) |