Home >Products> Reagents >ELISA / Diagnostic Kits> Rubella Virus Ab IgG/IgM Rapid Test
Reagents:  Molecular Biology   Biochemistry   Cell Biology   ELISA / Diagnostic Kits   Antibody   Serum/Medium   Other Reagents  
Rubella Virus Ab IgG/IgM Rapid Test
Rubella Virus Ab IgG/IgM Rapid Test
Place of Origin:
China
Brand:
SPAN
Model:
RV
Price:
Negotiable
Hits:
392 
Updated:
4/25/2025
  • Product Detail
  • Company Profile
    Rubella Virus Ab IgG/IgM Rapid Test

    SPECIMEN: Whole Blood/ Serum/ Plasma
     
    INTENDED USE
    The One Step RV IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Rubella (Virus) in Whole Blood /Serum / Plasma to aid in the diagnosis of RV infection. The test is based on immunochromatography and can give a result within 15 minutes. 
    PRINCIPLE
    The One Step RV IgG/IgM Test is a qualitative membrane strip based immunoassay for the detection of RV antibodies (IgG and IgM) in Whole Blood /Serum / Plasma. The test device consists of: 1) a burgundy colored conjugate pad containing RV recombinant envelope antigens conjugated with Colloid gold (RV conjugates) and rabbit IgG-gold conjugates,2) a nitrocellulose membrane strip containing two test bands (T1 and T2 bands) and a control band (C band). The T1 band is pre-coated with the antibody for the detection of IgM anti-RV, T2 band is coated with antibody for the detection of IgG anti-RV, and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. IgG anti-RV, if present in the specimen, will bind to the RV conjugates. The immunocomplex is then captured by the reagent pre-coated on the T2 band, forming a burgundy colored T2 band, indicating a RV IgG positive test result and suggesting a recent or repeat infection. IgM anti-RV if present in the specimen will bind to the RV conjugates. The immunocomplex is then captured by the reagent coated on the T1 band, forming a burgundy colored T1 band, indicating a RV IgM positive test result and suggesting a fresh infection. Absence of any T bands (T1 and T2) suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the T bands. Otherwise, the test result is invalid and the specimen must be retested with another device.
    Storage and Stability
    • Store as packaged in the sealed pouch at room temperature or refrigerated (4-30℃ or 40-86℉). The test device is stable through the expiration date printed on the sealed pouch.
    • The test must remain in the sealed pouch until use.
    Additional Special Equipment
     
    Materials Provided
    Test devices                               Disposable specimen droppers   
    Buffer                                        Package insert
    Materials Required But Not Provided
    Timer                                        Centrifuge
    Specimen collection containers        

    Precautions
    • For professional in vitro diagnostic use only. Do not use after expiration date.
    • Do not eat, drink or smoke in the area where the specimens and kits are handled.
    • Handle all specimens as if they contain infectious agents.
    • Observe established precautions against microbiological hazards throughout all procedures and follow the standard procedures for proper disposal of specimens.
    • Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
    • Follow standard biosafety guidelines for handling and disposal of potential infective material.
    • Humidity and temperature can adversely affect results. 
    Specimen Collection and Preparation
    1.The One Step RV IgG/IgM Test can be performed used on Whole Blood /Serum / Plasma.
    2.To collect whole blood, serum or plasma specimens following regular clinical laboratory procedures.
    3.Testing should be performed immediately after specimen collection. Do not leave the specimens at room temperature for prolonged periods. For long term storage, specimens should be kept below -20℃. Whole blood should be stored at 2-8℃ if the test is to be run within 2 days of collection. Do not freeze whole blood specimens.
    4.Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly.  

    Test Procedure
    Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.
    1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
    2.Place the test device on a clean and level surface.
    3.Hold the dropper vertically and transfer 1 drop of specimen (approximately 10μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 80μl) and start the timer. See illustration below.
    4.Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.

    Notes:
    Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer   to the specimen well.
     
    Interpretation of Results
    Positive: Control line and at least one test line appear on the membrane. The appearance of T2 test line indicates the presence of RV specific IgG antibodies. The appearance of T1 test line indicates the presence of RV specific IgM antibodies. And if both T1 and T2 line appear, it indicates that the presence of both RV specific IgG and IgM antibodies. The lower the antibody concentration is, the weaker the result line is.
    Negative: One colored line appears in the control region(C). No apparent colored line appear in the test line region.
    Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
     
    Our mission:

     
    • Always best of all and always pay attention to innovation.
    • Special customized service tightly following customers’ requests.
    • Integrated excellent quality, competitive prices and super service together.
     
    Rebecca Yan
     
    Product Manager                               
    Span Biotech Ltd.
    Tel:  +86(755)89589611
    Cell Phone:+8618823462100(WhatsApp)
    Web:
    bio-equip.cn
    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
    Efficiently structured to provide lasting and economic health care solutions with export ready goods, our main products cover the following immunodiagnostic rapid test kits:
    Rapid Tests for Human Use :
    1) Fertility: Pregnancy HCG, ovulation LH, menopause FSH
    2) Infectious diseases: Hepatitis B, HCV, HIV
    3) Drug abuse: AMP, BAR, BZO, COC, mAMP, MOP, MTD, OPI, PCP, TCA, THC
    4) Tumor markers: CEA, PSA, AFP, FOB
    5) STDs(Sexually Transmitted Diseases): Gonorrhea, syphilis, chlamydia
    6) New products: Malaria, H. Pylori, Multi-Hepatis B Panel (HBsAg, Anti-HBs, HBeAg, Anti-HBe, Anti-HBc), Blood Glucose Test, Multi-drug of Abuse Panel, Avian (Bird) Flu Rapid Test, etc.
    Rapid Tests for Veterinary :
    1) Bovine: Cow Pregnancy , Cow Ovulation, Bovine Brucella, Bovine Tuberculosis ,Food and Mouth Disease NSP Ab Test
    2) Canine: Canine Distemper, Canine Parvovirus, Canine Coronavirus
    3) Feline : Feline Leukemia Virus Ag Rapid Test ,Feline Panleucopenia Virus Ag Test,Feline Immunodeficiency Virus Ab Test
    Rapid Tests for Food Safety :
    1)For Antibiotics Residue : Nitrofurans (AOZ,AMOZ, AHD, SEM), Streptomycin , Sulfonamides , Chloramphenicol , Quinolone , Beta-Lactam&Tetracycline Combo (2 in 1), β-Lactams & Streptomycin & Chloramphenicol & Tetracyclines Combo (4 in 1), Beta-Lactam, Tetracycline test
    2) For Beta-Agonist Residue : Ractopamine, Clenbuterol ,Salbutamol
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.