    For professional in vitro diagnostic use only.

    The Trichomonas Vaginalis Antigen Rapid Test is intended for the qualitative detection of Trichomonas vaginalis(Trichomonas) antigens from vaginal swabs or from the saline solution prepared when making wet mount  from vaginal swabs. This kit is intended to be used as an aid in the diagnosis of Trichomonas infection.

    Trichomonas infection is responsible for the most common, non-viral sexually transmitted disease (vaginitis or trichomoniasis) worldwide. Trichomoniasis is a significant cause of morbidity among all infected patients.(1,2) Effective diagnosis and treatment of Trichomonas infections have been shown to eliminate symptoms.(2)  Conventional identification procedures for Trichomonas from vaginal swabs or vaginal washes involve the isolation and subsequent identification of viable pathogens by wet mount microscopy or by culture,(3) a process that will cost  24 -120 hours. Wet mount microscopy has a reported sensitivity of 58% versus culture.(4) The Trichomonas Rapid Test is an immunochromatographic assay that detects pathogen antigens directly from vaginal swabs. Results are rapid, occurring within approximately 10 minutes.

    The Trichomonas Vaginalis Antigen Rapid Test uses color immunochromatographic, capillary flow technology. The test procedure requires the solubilization of Trichomonas proteins from a vaginal swab by mixing the swab in Sample Buffer. Then the mixed sample buffer is added to the test cassette sample well and the mixture migrates along the membrane surface. If Trichomonas is present in the sample, it will form a complex with the primary anti-Trichomonas antibody conjugated to colored particles (red). The complex will then be bound by a second anti-Trichomonas antibody coated on the nitrocellulose membrane. The appearance of a visible test line along with the control line will indicate a positive result.
    20 Individually packed test devices Each device contains a strip with colored conjugates and reactive reagents pre-coated at the corresponding regions.
    2 Extraction Buffer vial 0.1  M  Phosphate  buffered  saline  (PBS)  and 0.02% sodium azide.
    1 Positive control swab
    (on request only)
    Contain inactived trichomonas and sodium azide. For External control.
    1 Negative control swab
    (on request only)
    Not contain trichomonas. For external control.
    20 Extraction tubes For specimens preparation use.
    1 Workstation Place for holding buffer vials and tubes.
    1 Package insert For operation instruction.
     
    • For professional in vitro diagnostic use only.
    • Do not use after expiration date indicated on the package. Do not use the test if its foil pouch is damaged. Do not reuse tests.
    • This kit contains products of animal origin. Certified knowledge of the origin and/or sanitary state of the animals does not totally guarantee the absence of transmissible pathogenic agents. It is therefore, recommended that these products be treated as potentially infectious, and handled observing the usual safety precautions (do not ingest or inhale).
    • Avoid cross-contamination of specimens by using a new specimen collection container for each specimen obtained.
    • Read the entire procedure carefully prior to performing any tests.
    • Do not eat, drink or smoke in the area where the specimens and kits are handled. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout the procedure and follow the standard procedures for proper disposal of specimens. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
    • Do not interchange or mix reagents from different lots. Do not mix solution bottle caps.
    • Humidity and temperature can adversely affect results.
    • When the assay procedure is completed, dispose the swabs carefully after autoclaving them at 121°C for at least 20 minutes. Alternatively, they can be treated with 0.5% sodium hypochloride (or house-hold bleach) for one hour before disposal. The used testing materials should be discarded in accordance with local, state and/or federal regulations.
    • Do not use cytology brushes with pregnant patients.
    • The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch.
    • The test must remain in the sealed pouch until use.
    • Do not freeze.
    • Cares should be taken to protect components in this kit from contamination. Do not use if there is evidence of microbial contamination or precipitation. Biological contamination of dispensing equipments, containers or reagents can lead to false results.
    Use only Dacron or Rayon tipped sterile swabs with plastic shafts. It is recommend to use the swab supplied by the kits manufacturer(The swabs are not contained in this kit, for the ordering information, please contact the manufacture or local distributor, the cataloge number is 207000). Swabs from other suppliers have not been validated. Swabs with cotton tips or wooden shafts are not recommended.
    • Insert the swab into the inside of the vagina, and rotate for 20sec. Pull the swab out carefully!
    • Do not place the swab in any transport device containing medium since transport medium interferes with the assay and viability of the organisms is not required for the assay. Put the swab to the extraction tube, if the test may be run immediately. If immediate testing is not possible, the patient samples should be placed in a dry transport tube for storage or transport. The swabs may be stored for 24 hours at room temperature (15-30°C) or 1 week at 4°C or no more than 6 month at -20°C. All specimens should be allowed to reach a room temperature of 15-30°C before testing.
    • Do not use 0.9% sodium chloride to treat swabs before collecting specimens.
    • The solution remaining in the test tube used for the wet mount may also be used as the sample for the trichomonas test. To use this sample type, add 3 drops of the solution to the sample well directly. These saline specimens may be held at room temperature for no longer than 24 hours. These specimens may also be stored at 4°C for up to 1 week or -20°C for 6 month.
    • To run a culture as well as the Test, Separate swabs must be collected because the sample buffer will kill Trichomonas organisms.
    Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.
    • Place a clean Extraction tube in the designated area of the workstation. Add 20 drops of Extraction Buffer to the extraction tube.
    Ÿ Put the specimen swab into the tube. Vigorously mix the solution by rotating the swab forcefully against the side of the tube for least ten times (while submerged). Best results are obtained when the specimen is vigorously mixed in the solution.
    Allow the swab to soak in the Extraction Buffer for one minute prior to the next Step.
    Ÿ Squeeze out as much liquid as possible from the swab by pinching the side of the flexible extraction tube as the swab is removed. At least 1/2 of the sample buffer solution must remain in the tube for adequate capillary migration to occur. Put the cap onto the extracted tube.
    Discard the swab in a suitable biohazardous waste container.
    • The specimens extracted can retain at room temperature for 60 minutes without affecting the result of the  test.
    • Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. To obtain a best result, the assay should be performed within one hour.
    • Add 3 drops (approximately 100 µl) of extracted sample from the Extraction Tube to the sample well on the test cassette.
    Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window.
    As the test begins to work, you will see color move across the membrane.
    • Wait for the colored band(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.
    Rebecca Yan
     
    Product Manager                               
    Span Biotech Ltd.
    Tel:  +86(755)89589611
    Cell Phone:+8618823462100(WhatsApp)
    Web:
     

     
    bio-equip.cn
    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
    Efficiently structured to provide lasting and economic health care solutions with export ready goods, our main products cover the following immunodiagnostic rapid test kits:
    Rapid Tests for Human Use :
    1) Fertility: Pregnancy HCG, ovulation LH, menopause FSH
    2) Infectious diseases: Hepatitis B, HCV, HIV
    3) Drug abuse: AMP, BAR, BZO, COC, mAMP, MOP, MTD, OPI, PCP, TCA, THC
    4) Tumor markers: CEA, PSA, AFP, FOB
    5) STDs(Sexually Transmitted Diseases): Gonorrhea, syphilis, chlamydia
    6) New products: Malaria, H. Pylori, Multi-Hepatis B Panel (HBsAg, Anti-HBs, HBeAg, Anti-HBe, Anti-HBc), Blood Glucose Test, Multi-drug of Abuse Panel, Avian (Bird) Flu Rapid Test, etc.
    Rapid Tests for Veterinary :
    1) Bovine: Cow Pregnancy , Cow Ovulation, Bovine Brucella, Bovine Tuberculosis ,Food and Mouth Disease NSP Ab Test
    2) Canine: Canine Distemper, Canine Parvovirus, Canine Coronavirus
    3) Feline : Feline Leukemia Virus Ag Rapid Test ,Feline Panleucopenia Virus Ag Test,Feline Immunodeficiency Virus Ab Test
    Rapid Tests for Food Safety :
    1)For Antibiotics Residue : Nitrofurans (AOZ,AMOZ, AHD, SEM), Streptomycin , Sulfonamides , Chloramphenicol , Quinolone , Beta-Lactam&Tetracycline Combo (2 in 1), β-Lactams & Streptomycin & Chloramphenicol & Tetracyclines Combo (4 in 1), Beta-Lactam, Tetracycline test
    2) For Beta-Agonist Residue : Ractopamine, Clenbuterol ,Salbutamol
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.