Home >Products> Reagents >ELISA / Diagnostic Kits> Malaria Pf/Pan Ag Rapid Test
Reagents:  Molecular Biology   Biochemistry   Cell Biology   ELISA / Diagnostic Kits   Antibody   Serum/Medium   Other Reagents  
Malaria Pf/Pan Ag Rapid Test
Malaria Pf/Pan Ag Rapid Test
Place of Origin:
China
Brand:
SPAN
Model:
Malaria
Price:
Negotiated
Hits:
734 
Updated:
4/25/2025
  • Product Detail
  • Company Profile
    Malaria Pf/Pan Ag Rapid Test
                                               
    For the qualitative detection of Malaria Pf/Pan antigen in whole blood
     
    INTENDED USE
    The Malaria Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of Plasmodium falciparum (Pf) antigen and P. vivax, P. ovale, or P.  Malariea antigen in whole blood. This device is intended to be used as a screening test and as an aid in the diagnosis of infection with Plasmodium. Any reactive specimen with the Malaria Rapid Test must be confirmed with alternative testing method(s) and clinical findings.
     
    SUMMARY AND EXPLANATION OF THE TEST
    Malaria is a mosquito-borne, hemolytic, febrile illness that infects over 200 million people and kills more than 1 million people per year. It is caused by four species of Plasmodium: P. falciparum, P. vivax, P.ovale, and P. malariae. These plasmodia all infect and destroy human erythrocytes, producing chills, fever, anemia, and splenomegaly. P. falciparum causes more sever disease than the other plasmodial species and accounts for most malaria deaths. P. falciparum and P. vivax are the most common pathogens, however, there is considerable geographic variation in species distribution1. Traditionally, malaria is diagnosed by the demonstration of the organisms on Giemsa stained smears of peripheral blood, and the different species of plasmodium are distinguished by their appearance in infected erythrocytes1. The technique is capable of accurate and reliable diagnosis, but only when performed by skilled microscopists using defined protocols2, which presents major obstacles for the remote and poor areas of the world.
    The Malaria Rapid Test is developed for solving these above obstacles. It detects the antibodies generated in serum or plasma in response to the infection of plasmodium. Utilizing the Pf. specific antigen (HRP-II) and pan-malaria antigen (aldolase), the test enables simultaneous detection and differentiation of the infection of P.falciparum and or P. vivax, ovale, and malariae3-5, by untrained or minimally skilled personnel, without laboratory equipment.
     
    PRINCIPLE
    The Malaria Rapid Test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing mouse anti-pHRP-II antibody conjugated with colloid gold (pHRP II-gold conjugates) and mouse anti-pLDH antibody conjugated with colloid gold (pLDH-gold conjugates), 2) a nitrocellulose membrane strip containing two test bands (T1 and T2 bands) and a control band (C band). The T1 band is pre-coated with monoclonal anti-pLDH antibody by which the infection with any of the four species of plasmodia can be detected, the T2 band is pre-coated with polyclonal anti-pHRP-II antibodies for the detection of Pf infection, and the C band is coated with goat, anti-mouse IgG.
    During the assay, an adequate volume of the blood specimen is dispensed into the sample well (S) of the test cassette, a lysis buffer is added to the buffer well (B). The buffer contains a detergent that lyses the red blood cells and releases various plasmodium antigens, which migrate by capillary action across the strip held in the cassette.
    pHRP-II if presents in the specimen will bind to the pHRP II-gold conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-pHRP-II antibodies, forming a burgundy colored T2 band, indicating a Pf positive test result.
    pLDH if presents in the specimen will bind to the pLDH gold conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti pLDH antibody, forming a burgundy colored T1 band, indicating a plasmodium positive test result. In the absence of T2 band, a positive test result for any of the other three plasmodia can be recommended.
    Absence of any T bands(T1 and T2) suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti-mouse IgG/mouse IgG (pHRP-II and pLDH-gold conjugates) regardless of the color development on any of the T bands. Otherwise, the test result is invalid and the specimen must be retested with another device.
     
    STORAGE
    Store the test kits at room temperature 4- 30 degrees C. The sealed pouch has a self life of 24 months.of transmitting disease.
     
    WARNING AND PRECAUTIONS
    1.For in-vitro diagnostic use only
    2.All patient samples should be treated as if capable of transmitting disease.
    3.Do not interchange reagents from different lots. Do not use it beyond expiration date.
     
    REAGENTS AND MATERIALS PROVIDED
    1.One pouch sealed with desiccant
    2.Blood diluent buffer in a dropper bottle
    3.One package insert
     
    MATERIALS REQUIRED BUT NOT PROVIDED
    1.  Clock or Timer
    2.  Lancing device for whole blood test
     
    SAMPLE COLLECTION AND PREPARATION
    Whole Blood
    Drops of whole blood can be obtained by either finger tip puncture or veinpuncture. Do not use any hemolized blood for testing.
    Whole blood specimens should be stored in refrigeration (2°Ċ-8 °Ċ) if not tested immediately. The specimens must be tested within 24 hours of collection.
    Test specimens as soon as possible after collecting. Store specimens at 2 to 8 °Ċ if not testedimmediately.
    Store specimens at 2 to 8 °Ċ up to 5 days. The specimens should be frozen at -20 °Ċ for longer storage.
    Avoid multiple freeze-thaw cycles. Prior to testing, bring frozen specimens to room temperature slowly and mix gently. Specimens containing visible particulate matter should beclarified by centrifugation before testing.
     
    ASSAY PROCEDURE
    Step 1:Bring the specimen and test components to room temperature if refrigerated or frozen. Mix the specimen well prior to assay once thawed.
    Step 2: When ready to test, open the pouch at the notch and remove device. Place the test device on a clean, flat surface.
    Step 3: Be sure to label the device with specimen’s ID number.
    Step 4: Apply 5ul whole blood into the sample well.Then add 4 drops of Sample Diluent. After 5min, add 2 drops again.
    Step 5: Set up the timer.
    Step 6: Results can be read in 30 minutes. Positive results can be visible in as short as 1 minute.
    Note: Don’t read result after 30 minutes. To avoid confusion, discard the test device after interpreting the result.
     
    INTERPRETATION OF RESULTS
     
    f005mar
     
    Negative: If only the C band is present, the absence of any burgundy color in the both T bands (T1 and T2) indicates that no plasmodium antigens are detected. The result is negative.                     
    Positive:
    Pf positive: In addition to the presence of C band, if only T2 band is developed, the test indicates for the presence of pHRP-II antigen. The result is Pf positive.
    Pan positive: In addition to the presence of C band, if only T1 band is developed, the test indicates for the presence of pLDH antigen. The result is either Pv, Pm, or Po positive.
    Mixed positive: In addition to the presence of C band, both T1 and T2 bands are developed, the test indicates for the presence of both pHRP-II and pLDH. The result is positive.
    Note: Samples with positive results should be confirmed with alternative testing method(s) and clinical findings before a positive determination is made.
    Invalid: If no C band is developed, the assay is invalid regardless of any burgundy color in the T bands as indicated below. Repeat the assay with a new device.
    PERFORMANCE CHARACTERISTICS
    Specificity & Sensitivity
    The Precision PreciMALARIA (P.f/Pan Antigen) Raped Test has been evaluated with positive and negative clinical samples tested by microscopic examination (Giemsa Staining) and PCR
    Specificity
      Malaria Negative Specimen Specificity
    PreciMALARIA P.F./Pan. Test Positive 2 99.6%
    Negative 465
    Total 467
     
    Sensitivity (P. falciparum)
      P.f Positive Confirmed Specimen Specificity
    PreciMALARIA P.F./Pan Test Positive 500 98.2%
    Negative 9
    Total 509
     
    Sensitivity (P.vivax)
      Pan Positive Confirmed Specimen Specificity
    PreciMALARIA P.F./Pan Test Positive 280 91.8%
    Negative 25
    Total 305
     
     
    LIMITATION
    1. The Assay Procedure and the Test Result Interpretation must be followed closely when testing the presence of plasmodium protozoa antigen in whole blood from individual subjects. Failure to follow the procedure may give inaccurate results.
    2. The Malaria Rapid Test is limited to the qualitative detection of plasmodium protozoa antigen in whole blood. The intensity of the test band does not have linear correlation with the antigen titer in the specimen.
    3. In the case of co-infection with Pf and any of the other three plasmodia, both T1 and T2 band will be developed. Thus, interpret the result cautiously when both T1 and T2 bands are visible.
    4. A negative result for an individual subject indicates absence of detectable plasmodium protozoa antigen. However, a negative test result does not preclude the possibility of exposure to or infection with plasmodium protozoa.
    5. A negative result can occur if the quantity of the plasmodium protozoa antigen present in the specimen is below the detection in which a sample is collected.
    6. Some specimens containing unusually high titer of heterophile antibodies or rheumatoid factor may affect expected results.
    7. The results obtained with this test should only be interpreted in conjunction with other diagnostic procedures and clinical findings.
     
    REFERENCE
    1. Malaria, p. 421-424. Chapter 9. Infectious and Parasitic Diseases. Rubin E., Farber JL. Pathology, 2nd ed. 1994. J.B. Lippincott, Philadelphia.
    2. Cooke AH, Chiodini PL, Doherty T, et al, Am J Trop Med. Hyp, 1999, Feb: 60(2):173-2
    3. Guthmann JP, et al: Trans R Soc Trop Med Hyg. 2002, 96(3):254-7
    4. Kar I, Eapen A, Adak T, Sharma VP, Indian J Malariol. 1998, 35(3):160- 2
    5. Mills CD, Burgess DC, Taylor HJ, Kain KC. Bull World Health Organ. 1999;77(7):553-9
    6. Cloonan N, Fischer K, Cheng Q, Saul A. Mol Biochem Parasitol. 113(2):327-30.
     
    PRODUCT DISCLAIMER
    This product has been manufactured under strict GMP regulation so to ensure the diagnostic accuracy of the test. It is out of control of the manufacture when the test is performed in diverse environment and by diverse group of individuals which may affect the result to a certain degree.
     
    NOTE
    The manufacture, the Distributor or its associates will not be liable for any losses, claims, liability, costs or damages, whether direct or indirect or consequential arising out of or related to an incorrect diagnosis, whether a positive or negative by use of this product.
     
    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
     
    Our mission:
    • Always best of all and always pay attention to innovation.
    • Special customized service tightly following customers’ requests.
    • Integrated excellent quality, competitive prices and super service together.
    Packaging Details:
    Pouch+Box+Carton packaging
    (1) With our company’s Logo
    (2) With the natural package
    (3) With OEM package
    (4) ODM

    Rebecca Yan
     
    Product Manager                               
    Span Biotech Ltd.
    Tel:  +86(755)89589611
    Cell Phone:+8618823462100(WhatsApp)
    Web:
    bio-equip.cn
    Span Biotech Ltd. is a research based company for rapid tests, with strong support from National Key Laboratory of Technology Projects of 10th and 11th Five-Year Plan and Faculty of Life Sciences of HuBei University. SpanBio also housed a R&D team that is developing gene recombination, cell cultivation and protein purification techniques. SpanBio pays strict attention on rapid tests for human being, animal diseases and food safety detection. It provides a number of customized services to professional distributors and partnering affiliates with excellent quality, competitive prices and super service.
    Efficiently structured to provide lasting and economic health care solutions with export ready goods, our main products cover the following immunodiagnostic rapid test kits:
    Rapid Tests for Human Use :
    1) Fertility: Pregnancy HCG, ovulation LH, menopause FSH
    2) Infectious diseases: Hepatitis B, HCV, HIV
    3) Drug abuse: AMP, BAR, BZO, COC, mAMP, MOP, MTD, OPI, PCP, TCA, THC
    4) Tumor markers: CEA, PSA, AFP, FOB
    5) STDs(Sexually Transmitted Diseases): Gonorrhea, syphilis, chlamydia
    6) New products: Malaria, H. Pylori, Multi-Hepatis B Panel (HBsAg, Anti-HBs, HBeAg, Anti-HBe, Anti-HBc), Blood Glucose Test, Multi-drug of Abuse Panel, Avian (Bird) Flu Rapid Test, etc.
    Rapid Tests for Veterinary :
    1) Bovine: Cow Pregnancy , Cow Ovulation, Bovine Brucella, Bovine Tuberculosis ,Food and Mouth Disease NSP Ab Test
    2) Canine: Canine Distemper, Canine Parvovirus, Canine Coronavirus
    3) Feline : Feline Leukemia Virus Ag Rapid Test ,Feline Panleucopenia Virus Ag Test,Feline Immunodeficiency Virus Ab Test
    Rapid Tests for Food Safety :
    1)For Antibiotics Residue : Nitrofurans (AOZ,AMOZ, AHD, SEM), Streptomycin , Sulfonamides , Chloramphenicol , Quinolone , Beta-Lactam&Tetracycline Combo (2 in 1), β-Lactams & Streptomycin & Chloramphenicol & Tetracyclines Combo (4 in 1), Beta-Lactam, Tetracycline test
    2) For Beta-Agonist Residue : Ractopamine, Clenbuterol ,Salbutamol
Request Information
Request Information: yes no
Request Quotation: yes no
refresh

I agree to share my inquiry with the other matching suppliers.

Request Information

* Name:
Job Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request Information:
yes no
Request Quotation:
yes no
* Message:
* Verification Code:
refresh
I agree to share my inquiry to the other matching suppliers.