. First, run the company in the ME series of coagulation tests mixing instrument (coagulation test mixer) are using micro-computer control technology
Surgery technology has the following characteristics:
1. The work of the entire Chinese interface, large-screen liquid crystal display, each menu prompt steps, only button option, very simple to use.
2. Can store 12 sets of procedures, each procedure could be 10 different speed; procedures for the preparation, modification is very convenient.
3. Run-time parameters (program number, speed, time, temperature, velocity gradient G value, GT value) wide screen display, working status at a glance.
4. Synchronous operation: first of all agitation run by the same procedure (Figure 3). Stand-alone: at the same time to run six different procedures (Figure 4) can be greatly reduced the number of experiments to compare different results of mixing process on the effects of coagulation.
5. High-precision stepper motor, the output speed by the computer chip digital signal control, very precise, perfectly synchronized, parallel with the experimental data.
6. Separate controller and chassis design, so that maintenance is very easy to replace. Mixing, Dosing and functional movements controlled by the three circuit boards, maintenance can only replace the circuit board, a very low maintenance costs and faster
7. Stainless steel mixing motor impeller directly linked, non-mechanical transmission device, to avoid the traditional mixer drive belt and gear, such as the frequent failure of the defective parts.
8. Mixing the first movements to adopt the way to the back flip, as compared with the direct upgrade from top to bottom, low noise, fast movements, only four seconds.
9. Automatic calculation of velocity gradient G value, GT value: a better practice and production.
Automatic Dosing: reach set speed automatically synchronized to the beaker with a good distribution of liquid; can be many times more than
Automatic Dosing varieties, so the pilot to maintain a good synchronization.
Automatic upgrade: After the mixing, or from the impeller surface automatically, to spend the settlement does not affect the alum.
Automatic water measured temperature: involvement of G value, GT value.
10. All models with round or square perspex beaker (1L, 1.5L), 6 beaker shape and exactly the same as the outlet to ensure synchronization of test results. Cup side the concept of our company in the domestic launch of the first, with the international movement of coagulation current test methods consistent choice for customers.
Second, technical parameters:
1. Speed:
2. Period of time for each run:
0 ~ 99 minutes 99 seconds (one for each process running up to 10), the time accuracy: ± 0.1%.
3. Temperature: 0 ~ 50 ℃, temperature measurement accuracy: ± 1 ℃.
4. Power: 220V ± 5%, 50/60Hz. Power: the two together, 40W; six together, 180W
5. weight:32.5 Kg
6. size: 93×47×50cm
bio-equip.cn
Med-int-048 digital brain stereotaxic instrument is used outside the skull logo or other reference point under the three coordinate system, to determine the subcortical location of certain neural structures in order to look directly at the non-exposed conducted under the direction of their stimulation, damage, injection drugs, and other research to guide potential.
Med-int-048 digital brain stereotactic apparatus is neuroanatomy, neurophysiology, and neurosurgery Neuropharmacology important areas of research equipment for the orientation of the neural structure of the injection, stimulation, damage, guide potential, etc, can be used for animal model of Parkinson's disease, epilepsy animal model, brain tumor model, learning and memory, neural stem cell transplantation, cerebral ischemia and other research.
Med-int-048 digital brain stereotactic apparatus is the most cost-effective, standards-based computer with all the features of stereotactic apparatus, and the original standard brain stereotaxic apparatus on the basis of three-dimensional manipulator with an increase of displacement sensor and LCD display, direct reading digital mobile distance, greatly facilitate the reading process of the experiment; three-dimensional manipulator display any point calibration, positioning directly under the map, to avoid the second reading and calculation, simplified the experimental operation ; move away from the reading accuracy of 10 microns, to meet higher test requirements; sensors and LCD display built-in integrated embedded operating arm, place the screen and no additional cables, external appearance and space saving console; button long battery life replacement and maintenance.