Login    Join free Add to favorites    中文
Home >Products> Cryostat | Freezers | Thermostat >Low Temperature Freezers> Blood Bank High Accuracy Sensor Platelet Agitator Incubator LED Clear Display Platelet Incubator
Blood Bank High Accuracy Sensor Platelet Agitator Incubator LED Clear Display Platelet Incubator
Blood Bank High Accuracy Sensor Platelet Agitator Incubator LED Clear Display Platelet Incubator
Origin of place China
Model
Supplier Hunan Kaida Scientific Instruments Co., Ltd
Price judy@kaidasy.com
Hits 2465
Updated 3/31/2025
  • Product Detail
  • Company Profile

Blood Platelet Incubator     

Appliance:

1. To store blood platelet (20-24℃), biological reagent (2-40℃), chemical products stored at 2-40℃.  

2. Suitable for Hospital, blood station, research institute and university labs.

 

Refrigeration System

1. Branded condenser fan.

2. Imported compressor, CFC-free refrigerant.

3. Forced air cooling system, fast cooling speed and uniformity temperature inside.

4. Imported evaporator for safety and longevity.

5. Finned evaporator for more effective cooling and speedy recovery without condensation and accumulated water.

6. Double transparent insulation glass door, filled with inert gas ensure the cooling performance.

 

Temperature Control

1. Microprocessor-based temperature controller, digital temperature display, temperature resolution is 1℃.

2. Standard thermal printer can track and record the change of the temperature all-the-way.

3. Inner with SUS, external with color sprayed steel, foam glass door with electric heating, free from condensation, inner door, perfect insulation performance.

 

Operating Security

1. Japan imported oscillation slide rail for longevity and low sound.

2. High/Low temperature alarms, sensor error alarm, power failure alarm.

3. Two alarm styles: audible buzzing and visual flashing light.

4. Power cord with earth leakage protection.

5. Door ajar alarm.

 

Avoid Falsification and Wrong Operation

Keyboard lock and password protection function, avoid set parameter randomly.

 

Power Failure Protection

When power restores, all devices would kick-off at one time, which could cause great impact to the power network, could lead to circuit breaker tripping. The delay start function would protect the equipment for several minutes during restore period and make sure all devices operate normally.

 

Humanized Design

1. Disinfection with UV, set disinfection time freely; UV light would off while door open to protect human body.

2. Temperature printer can be set as needed.

3. Wide voltage from 187V~242V.

4. Foam glass door design, better temperature without any affection on read.

5. Self-closed and stop structure design, prevent door shut, easy to use.

6. Patented temperature box design, make the display temperature closer to blood temperature.

7. SUS inner tank, anti-rust, anti-corrosion

Parameter

Model

External Size mm

Internal Size mm

Voltage (V/Hz)

Power (W)

Temperature inside(℃)

Climate type

Layers (450ml blood bags)

N.W. (Kg)

KDC-5

522*600*1050

427*360*467

220/50

197

20-24/2-40℃

N

5 Layers/10 bags

60

KDC-10

522*600*1300

432*462*728

220/50

280

20-24/2-40℃

N

10 Layers/20 bags

80

 

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号