Login    Join free Add to favorites    中文
Home >Products> Other Lab Equipments >Miscellaneous> Single Channel Syringe Pump for Hospitals
Single Channel Syringe Pump for Hospitals
Single Channel Syringe Pump for Hospitals
Origin of place China
Model RSD810SA
Supplier Ronseda Electronics Co., Ltd.
Price
Hits 629
Updated 9/11/2015
  • Product Detail
  • Company Profile

 Features

1.Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions

2.Human voice alarms for occlusion, empty, near empty, low battery, end of infusion, syringe loose,  wrong setting etc

3.Preset solution volume can greatly reduce nurse workloads

4.HD LCD Display, high capacity words, friendly user interface, dynamically display working status

5.Three work modes: Rate mode, Time Volume mode, Dosage Weight mode

6.Compatible with 10ml, 20ml, 30ml, 50/60ml syringe of any brands after calibration

7.KVO and Bolus functions

 

Specifications

Unique Human Voice Alarm system

The device triggered the human voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.

Injection Rate:

50/60ml Syringe:  0.1ml/h~999.9ml/h   (0.1ml/h step)
1,000ml/h~1,500ml/h   (1ml/h  step)
30ml Syringe: 0.1ml/h~900.0ml/h    (0.1ml/h step)
20ml Syringe:  0.1ml/h~600.0ml/h   (0.1ml/h step)
10ml Syringe:  0.1ml/h~300.0ml/h   (0.1ml/h step)

Flow Rate Accuracy:

Within 3% (after correct calibration)

Mechanical precision:

Within 2%

Bolus Rate:

50/60ml Syringe:  1,200ml/h
30 ml Syringe:  720ml/h
20 ml Syringe:  480ml/h
10 ml Syringe:  240ml/h

Purge Rate:

50/60ml Syringe:  1,500ml/h
30ml Syringe:  900ml/h
20ml Syringe:  600ml/h
10ml Syringe:  300ml/h

Volume Limit:

0.1ml~999.9ml

Total Injection
Volume:

0.1ml~9999.9ml (0.1ml step)

Occlusion:

High:   800mmHg 200mmHg     (106.7kPa26.7kPa)
Medium: 50/600mmHg
100mmHg  (66.7kPa13.3kPa)
Low:    300mmHg
100mmHg    (40.7kPa13.3kPa )

Alarms:

Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc.

Power Source:

AC 100V~240V, 50/60Hz; Internal rechargeable Li battery, capacity=1,600mAh, 4 hours internal battery backup

KVO rate:

1ml/h

Fuse:

F1AL/250/60V, 2pcs inside

Power Consumption:

30VA

IP Classification:

IPX4

Equipment Classification:

Class I, internal power supply, Type CF

Operating Condition:

Ambient temperature: +5?~+40?;

Relative humidity:

20~90%

Transport & Storage Condition:

Ambient temperature: -30?~+55?

Relative humidity:

=95%

Dimension:

280mm (L) 210mm (W) 130mm (H)

Weight:

2.2kg (net weight)

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号