Login    Join free Add to favorites    中文
Home >Products> Spectrum | HPLC | GC | MS >HPLC / FPLC > Sepax HP-C18 Columns
Sepax HP-C18 Columns
Sepax HP-C18 Columns
Origin of place United States
Model
Supplier Sepax Technologies, Inc.
Price
Hits 1143
Updated 4/1/2013
  • Product Detail
  • Company Profile

HP-C18 uses full coverage bonded silica packing, which provides high stability. Compatible with 100% aqueous mobile phase and suitable for separations of acidic, neutral and basic organic compounds, as well as pharmaceuticals and peptides. ODS monolayer formed by special bonding chemistry does not collapse in pure aqueous solution. 

Packing

 

Silica: Spherical, high purity (<10 ppm metals)
Pore size: 120
Particle size: 3, 5, and 10 µm
Pore volume: 1.0 ml/g
Surface area: 300 m²/g
Phase structure: Monomeric and fully endcapped
% Carbon: 17%

 

Silica: Spherical, high purity (<10 ppm metals)
Pore size: 200
Particle size: 3 and 5 µm
Pore volume: 1.0 ml/g
Surface area: 200 m²/g
Phase structure: Monomeric and fully endcapped
% Carbon: 10%

Characteristic

  • Highly controlled chemistry of monolayer formation and end-capping
  • Extremely high column-to-column reproducibility
  • High selectivity and efficiency for separations
  • Compatible with 100% aqueous mobile phase
  • Suitable for separations of acidic, neutral and basic organic compounds, as well as pharmaceuticals, peptides, and others

 

Stability

Sepax HP-C18 uses full coverage bonded silica packing, which provides the exceptionally high stability. Figure 1 shows the highly reproducible retention time for three standard compounds: aniline, anisole and toluene after 13,000 column volume runs in a mobile phase of 85% methanol and 15% water. Such high stability allows Sepax HP-C18 extremely suitable for validation of various analytes.

 

 

Reproducibility

Figure shown below is a real application of Sepax HP-C18, showing fast separation of 8 pharmaceutical molecules by a 3 µm, 4.6×50mm short column. After 1800 column volume of "0.1% TFA and CH3CN mobile phase" was pumped, the column still shows almost identical performance!

 

(Courtesy of Miyako Kawakatsu, M&S Instruments Inc.)

 

Selectivity

Sepax HP-C18 has better selectivity and resolution for organometallic complex isomers compared to other competitors' C18 phases.

 

(Courtesy of Dr. John Lin of Avantix Laboratories)

Conditions  
Column selection: 1. Phenomenex, Synergi, Polar-RP, 4 µm, 50×2.0 mm
2. Keystone, AQ C18, 3 µm, 50×2.0 mm
3. MetaChem, Polaris-C18, 3 µm, 50×2.1 mm
4. Sepax HP C18, 3 µm, 50×2.1 mm
Mobile phase: A: 0.1% TFA in water with 10 mM ammonium formate
B: 0.1% TFA in methanol with 10 mM ammonium formate
Gradient elution  
Flow rate: 0.5 mL/min
Injection volume: 10 µL
Temperature: 25 °C
Instrument: API 4000 LC-MS/MS system
Compounds: Two organometallic complex isomers: M40403 and M40531
(The molecular structures were not disclosed from the customer.)

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号