Login    Join free Add to favorites    中文
Home >Products> Spectrum | HPLC | GC | MS >HPLC / FPLC > Sepax Glycomix SAX Columns
Sepax Glycomix SAX Columns
Sepax Glycomix SAX Columns
Origin of place United States
Model
Supplier Sepax Technologies, Inc.
Price
Hits 1474
Updated 4/1/2013
  • Product Detail
  • Company Profile

Description

Glycomix™ strong anion-exchange phase is made of narrow-dispersed and hydrophilic polymer particles. It is a strong anion exchanger with quaternary ammonium functional groups that are chemically bonded to the hydrophilic surface of the polymer particles.

Packing

Chemical composition of Glycomix™ SAX

 

 

Glycomix™ SAX Technical Specifications

Characteristics Glycomix™ SAX
Functional Group Quaternary ammonium
Surface characteristics Hydrophilic
pH range 2 - 12
Typical backpressure for 4.6×250 mm 10 bar for 0.22 mL/min
38 bar for 1 mL/min
Maximum backpressure ~ 1,500 (psi)
Salt concentration range 20 mM - 2.0 M
Maximum temperature ~ 80 (°C)
Mobile phase compatibility Aqueous and organic
Applications Heparin, highly charged polysaccharides

 

 


 

Characteristic

Featured Characteristics

  • High capacity and high resolution
  • High lot-to-lot reproducibility
  • Wide pH range (2-12)
  • From analytical to preparative scale
  • Ideal for separation and analysis of heparin, glycans

 

 

 

 

 

High Lot to lot Reproducibility

With well-controlled surface chemistry and resin production, Glycomix resins exhibit high lot to lot reproducibility which leads to consistent column performance. The separation variation for Heparin from batch to batch is less than 1% for retention time and 5% for the peak area.

 

Figure 2. High Lot-to-lot reproducibility of three lots of Glycomix™ SAX resins.

Conditions  
Column: Glycomix™ SAX, 4.6×250mm
Mobile phase: A: 0.04% NaH2PO4, pH 3.0
B: 0.04% NaH2PO4+14% NaClO4, pH 3.0
Flow rate: 0.22 mL/min
Gradient: 20% - 90% B in 60 minutes
Wavelength: 202 nm
Temperature: 25 °C
Injection volume: 10 µL
Pressure: 9.5 bar
Sample: 20 mg/mL Heparin sodium
1 mg/mL Dermatan sulfate (DS)
1 mg/mL Oversulfated chondroitin sulfate (OSCS) in H2O

 

Lot-to-Lot peak retention time relative standard deviation.

Peak Name Lot A Lot B Lot C RSD%
Chondroitin Sulfate B 12.286 12.300 12.434 0.41%
Heparin 21.71 21.723 21.919 0.44%
OSCS 33.936 33.853 34.114 0.32%

Long column life time

Glycomix™ SAX has long column life time due to its resin surface chemistry and stable manufacturing process. Figure below exhibits one column's performance for duplicated injections. The column shows consistent separation efficiency.

 

Figure 3. Chromatogram overlays of duplicated injections.

Conditions  
Column: Glycomix™ SAX, 4.6×250mm
Guard Column: Glycomix™ SAX, 4.6×50mm
Mobile phase: A: 0.04% NaH2PO4, pH 3.0
B: 0.04% NaH2PO4+14% NaClO4, pH 3.0
Flow rate: 0.22 mL/min
Gradient: 20% - 90% B in 60 minutes
Wavelength: 202 nm
Temperature: 25 °C
Injection volume: 10 µL
Pressure: 9.5 bar
Sample: 20 mg/mL Heparin sodium
1 mg/mL Dermatan sulfate (DS)
1 mg/mL Oversulfated chondroitin sulfate (OSCS) in H2O

Sensitive separation of different Heparin loading

Glycomix™ SAX is able to separate components from commercially available standards. In Figure 4, Panel A shows the standard run with 20mg/mL Heparin, 1mg/mL DS and 1 mg/mL OSCS. Panel B is the OSCS chromatogram with 1 mg/mL concentration. In comparison to Panel B, the small peak between DS and Heparin comes from the standard OSCS sample. Column running conditions are the same as for Figure 3.

Glycomix™ SAX can be used in the quantitative analysis of Heparin and its impurities. Figure 5 shows the different heparin loadings over concentration range from 0.5 mg/ml to 10 mg/ml, 0.125 mg/ml to 4 mg/ml for OSCS and 0.25 mg/ml to 4 mg/ml for DS. The R2 values for both standards exceed 0.99 in the tested concentration range.

 

Figure 4. Chromatogram overlays of OSCS standard and Heparin with DS and OSCS.

 

Figure 5. Chromatogram overlays of different heparin injections from 0.5mg/mL to 10mg/mL concentration, DS from 0.125 mg/mL to 4.0 mg/mL and OSCS from 0.25 mg/mL to 4.0 mg/mL.

 

Conditions  
Column: Glycomix™ SAX, 4.6×250mm
Guard Column: Glycomix™ SAX, 4.6×50mm
Mobile phase: A: 0.04% NaH2PO4, pH 3.0
B: 0.04% NaH2PO4+14% NaClO4, pH 3.0
Flow rate: 0.22 mL/min
Gradient: 20% - 90% B in 60 minutes
Wavelength: 202 nm
Temperature: 25 °C
Injection volume: 10 µL
Pressure: 9.5 bar
Sample: 20 mg/mL Heparin sodium
1 mg/mL Dermatan sulfate (DS)
1 mg/mL Oversulfated chondroitin sulfate (OSCS) in H2O

Column Performance Comparison

In comparison, Glycomix™ SAX performs superior to Dionex's column for heparin separation.1,2 Figure 7 shows the chromatogram of Heparin separation from Glycomix™ SAX. The resolutions are 3.8 between DS and heparin, 5.8 between heparin and OSCS. The U.S. Pharmacopeia (USP) requirements for the separation for DS/ heparin are 1.0 and 1.5 for OSCS /heparin3. GlycomixTM SAX has a much better separation resolution than USP's requirement. In Dionex's application note, Dionex IonPac AG11 guard with AS11 analytical column gives a 1.1 and 1.8 resolution for DS/heparin and heparin/OSCS respectively.

Figure 7. Heparin Sodium, Chondriotin Sulfate B, and Oversulfated Chondroitin Sulfate separation on Glycomix™ SAX.

Conditions  
Column: Glycomix™ SAX, 4.6×250mm
Guard Column: Glycomix™ SAX, 4.6×50mm
Mobile phase: A: 0.04% NaH2PO4, pH 3.0
B: 0.04% NaH2PO4+14% NaClO4, pH 3.0
Flow rate: 0.22 mL/min
Gradient: 20% - 90% B in 60 minutes
Wavelength: 202 nm
Temperature: 25 °C
Injection volume: 10 µL
Pressure: 10 bar
Sample: 20 mg/mL Heparin Sodium
0.2 mg/mL Dermatan Sulfate (DS)
0.2 mg/mL Oversulfated Chondroitin Sulfate (OSCS)

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products