AutoTFF 075 is a flexible and automated lab scale crossflow filtration system that can be used with hollow fibers or cassette filters for concentration, diafiltration or clarification of samples. It is widely used in biological product process, such as antibodies, recombinant proteins,
mRNA, nucleic acids, viral vectors, etc. Its flexible configuration allows for manual operation and highly automated process control. Combined with a comprehensive management system, it is suitable for small-scale process development, process scale up study, and sample preparation
AutoTF 075 system consists of buffer transfer module, recirculation vessel module, feed module, retentate module, filtrate module, filter
holder, control software, etc. The system can be configured according to different process requirement to realize different levels of automation.
Recirculation vessel
● The system comes with a 1L circulation vessel that complies with USP Class VI, with mixing and weighing module at the bottom. The weight is
monitors in real time, and achieve automatic concentration endpoint control and continuouse dialysis.The vessel can be easily emptied with
conical bottom design.
Feed pump
● A peristaltic pump or a low shear force diaphragm pump can be choosed as the feed pump, with a maximum flow rate of 700ml/min, which can
achieve constant flow rate or constant inlet pressure,differential pressure.
Buffer transfer module
● The system can be equipped with transfer pump and inilet valve, which is used for automatic filling of the circulating vessel.
Detector
● The system is equipped with three pressure sensors(2 for module L): inlet, retentate, and permeate, to achieve pressure monitor ing and
calculation of differential pressure and TMP. Conductivity, pH, UV detectors are optional.
Permeate control
● Optional permeate pump allows control of permeate flowrate. It is widely used in microfiltration process. Control the permetate flux can reduce
fouling ot the membrane and slow down the formation of gel layer, which is beneficial for improving the overall process efficiency.
 
PCV
● The retentate is equipped with an automatic clamp valve(manual valve for module L), which can automatically control the retentate pressure
and achieve automatic adjustment of TMP.
Control software
● The control software can be used for system control, method editing, data recording, user management, equipment calibration, etc. Standard
method modules include clean water flux test, CIP, clarification/concentration, dialysis, harvest/drain, filling, system flushing, etc. Users can
easily create a whole recipe by combining different method mocules.
 Predefined method modules
 
Method Module Function
Filling Add a certain amount of liquid to the circulation vessel
Water flux test Can automatically test water flux based on defined pressure/crossflow conditions
Clarification/Concentration Concentrate the feed liquid to the defined volume or concentration factor
Diafiltration Constant volume diafiltration with continuouse feed entill predefined endpoint, eg.
Harvest/Drain Diltiltration volume, conductivity, pH
CIP Harvest the liquid through the harvesting port or outlet valve
Flush Used for system cleaning
Pause Flush the system with water, buffer or other solutions
Filling  
 
 
AutoTFF™075 Specification
Dimensions(LxDxH,mm) 580 x 355 x 640 (filter holder not included))
Electrical requirements 240VAC, 50-60Hz
Weight 48kg(include 0.1m² filter holder)
Power 150W
System language Chinese, English
Ambient temperature 2-35°C
 
 
 
 
 
 
Filtration area 50cm²- 0.1m²(The specific filtration area can be varied with different filters)
Maximum feed pressure 5bar
Minimum recirculating volume 20ml
Process temperature 2-50°C
Feed pump flow rate 0-700ml/min
Retentate pump flow rate 0-600ml/min
Permeate pump flow rate 0-300ml/min
Recirculation vessel volume 1000ml
Stirring speed 0-300rpm
Pressure sensor Detection range: 0-5Bar
Conductivity sensor Detection range: 0-999.999ms/cm,
Temperature sensor Integrated in conductivity sensor, detection range: 0-99 ° C
pH Detection range: 1-14
Retentate and filtration weighing 0-6kg
Filter holder 1 ABS multifunctional holder for 50cm ² Capsule capsule or hollow fiber filters with a diameter
no more than 50mm
1 0.1m ² Stainless steel holder
Tube&Connector Luer Lock

 
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号