In scientific research institutions or pharmaceutical companies, some biological samples need to be stored in liquid nitrogen sample storage tanks.
Liquid nitrogen sample storage tanks are an important cryogenic storage equipment that many people are not familiar with. So as a manufacturer of KGSQ liquid nitrogen tank, let me briefly introduce how to use it.
1. Before use, you need to carefully check the appearance to see if there is any dent or damage, and whether the vacuum exhaust port is intact. These inspections are to ensure that the thermal insulation performance of the liquid nitrogen tank is good.
2. Liquid nitrogen tanks rely on liquid nitrogen to ensure deep and low-temperature storage, so the tanks can only be filled with liquid nitrogen. Mixing other flammable substances can easily cause interaction and cause an explosion.
3. The liquid nitrogen tank container should be placed in a cool, dry place to ensure good indoor ventilation.
4. The temperature of liquid nitrogen is -196°C. Self-protection measures should be taken when extracting and storing the freezing rack, such as wearing leather or cotton gloves. Be cautious when operating with bare hands. At the same time, it is necessary to prevent liquid nitrogen from splashing, which may cause frostbite when it touches the skin and other parts.
5. When filling liquid nitrogen for the first time, because the vacuum liner is at normal temperature, it is not advisable to fill it too fast. A small amount should be injected first to gradually reduce the temperature of the liner. Injecting a large amount of liquid nitrogen can easily cause the liquid nitrogen to boil. At this time, slow down. Wait for the liquid nitrogen to cool down slightly before injecting liquid nitrogen faster. Otherwise, the liquid nitrogen will boil and splash outward, causing frostbite.
6. Liquid nitrogen should not be overfilled, and the liquid level should not be in contact with the fiberglass neck tube.
7. Liquid level height check: Insert a wooden ruler vertically into the center bottom of the liquid nitrogen tank and take it out after about 15 seconds. The frost length is the liquid level height. Never use a hollow tube for inspection to prevent liquid nitrogen from erupting from the tube and injuring people.
8. Make sure that the liquid nitrogen submerges the refrigerated items. When the liquid nitrogen is consumed to the point where the refrigerated items are about to be exposed to the liquid surface, liquid nitrogen should be replenished in time.
If you have any needs, please contact KGSQ liquid nitrogen tank:
Email: tcln2container@126.com
WhatsApp: +8618903712477
Official website:
https://www.cryogenicstoragetank.com/YDS-Series-with-Racks-Boxes.html
bio-equip.cn
Zhengzhou jinshui district jinuo experimental analysis equipment is located in Zhengzhou, China, specializing in the production and sales of liquid nitrogen tanks and cryogenic biological containers. The company independently manufactures liquid nitrogen tanks as its core products, offering YDS-series tanks (ranging from YDS-2 to YDS-100), transport liquid nitrogen tanks, and related accessories. These products are widely utilized across diverse sectors, including livestock breeding, hospital research, academic institutions, bioengineering, food inspection, and industrial cryogenic treatment.
Furthermore, Zhengzhou Jinshui Jinuo Experimental Analysis Equipment Factory serves as an authorized marketing and promotion partner for TcCryo.
About TcCryo
TcCryo offers a comprehensive range of cryogenic products, including laboratory liquid nitrogen dewars, biological sample storage systems, liquid nitrogen containers for animal breeding and artificial insemination, dry shippers, liquid nitrogen supply tanks, and customized cryogenic equipment.
The brand focuses on practical product design, manufacturing quality, and application-specific solutions to meet the needs of laboratories, biobanks, livestock breeding facilities, distributors, and other B2B customers.
Manufacturing & Quality Control
The company's manufacturing capabilities cover vessel fabrication, vacuum insulation processing, and surface finishing. Its quality control processes include helium mass spectrometry leak testing, vacuum inspection, static evaporation rate testing, and final product inspection.
These manufacturing and inspection capabilities support consistent product quality and performance across its cryogenic equipment range.
Global B2B Services
TcCryo supports international customers through standard product manufacturing, OEM/ODM services, customized production, and technical product selection assistance. The company works with distributors, wholesalers, importers, and end users to provide cryogenic storage products suited to different applications and requirements.
Company Information
Company Name: Henan Tianchi Cryogenic Machinery Equipment Manufacturing Co., Ltd.
Brand: TcCryo
Brand Ownership: Registered trademark owner in China
Business Type: Manufacturer
Main Business: Liquid Nitrogen Storage Containers & Cryogenic Equipment
Manufacturing Experience: Over 20 Years
Official Website: https://www.cryogenicstoragetank.com/
https://www.cryogenicstoragetank.com/
Contact: +86 18903712477
Liquid Nitrogen Tanks, Livestock Semen Storage Tanks, Biological Laboratory LN₂ Tanks, Aviation Dry-Shipper Tanks, Stem Cell Cryogenic Tanks, Self-Pressurized LN₂ Containers, Vapor Phase Liquid Nitrogen Tanks, Liquid Level Alarms, and LN₂ Transport Carts.
Direct Manufacturer
Supplying to 40+ Countries Globally
20 Years of Focused Expertise in One Field
Annual Production Capacity of 70,000 Tanks
100% Quality Inspection
Efficient Delivery & Same-Day Order Dispatch
24/7 Responsive Support
Customized Cryogenic Storage Solutions
Customized for Labs, Biobanks & Farms
OEM/ODM Services Available