High sensitivity, good stability, compatibility, simple operation, long-time life
SAINAER designed E800 which is a typical evaporative light scattering detector . Advanced detection room processing technology can keep service life of the detection room to be up to 10 years
Humanized interface (double signal output of digital signal and analog signal)
The combination of high sensitivity photomultiplier tube and laser ensures high detection sensitivity
Advantage
- Advanced technology of test room can make the working life of test room more than 10 years
- It can work with any brand/model of liquid chromatography to be automatic sample injection, automatic collection and automatic data storage
- A digital gas flow control system can ensure stable atomization effect and perfect peak shape
- The combination of high sensitivity photomultiplier tube and laser ensures high detection sensitivity
- Double signal output with digital signal, analog signal
- New chromatographic software and control system is simple and easy to use
- Visual design of flow chamber
- Evaporation temperature range : room temperature + 3 ℃ to 130 ℃
Parameter list
- Operation mode:Split flow, low temperature evaporation.
- Work with HPLC:Work with any brand/model of liquid chromatography.
- Software: The instrument parameters are controlled through the keyboard, and the injection sequence can be arranged together with other brands of HPLC. It complies with the GLP and FDA CFR21 Part 11 specifications. It has its own database, and its permissions can be customized to meet audit tracking requirements.
- Detecting element:High sensitivity photomultiplier.
- Light source:Laser with a maximum output of 30mW (the light source has a lifespan of 20,000 hours).
- Special light source design:Laser coaxial device avoids the unstable influence of vibration on the instrument.
- Warped flow function:YES.
- Display mode:LED.
- Control way:Keyboard control.
- Drift tube insulation:Double layer insulation.
- Is it convenient to clean the atomizer:Yes, Front panel design is easy to atomizer cleaning.
- Atomized gas type:Compressed air or nitrogen.
- Gas valve switch control:Yes.
- Gas flow control:Yes, the built-in digital gas quality flow control system is not affected by pressure changes.
- Range of gas flow direction:0.0 to 4.5 L/min can be adjusted.
- Accuracy of gas flow control:0.01L/min.
- Stability of gas flow:±0.02/min.
- The anti-corrosion treatment:Drift tube and the inner wall of the detection area are specially inert to reduce the failure rate and the life can be up to 10 years.
- Drift control temperature range:Room temperature + 3 ℃ to 130 ℃.
- Step of drift tube temperature:1℃.
- Temperature stability of drift tube:±0.5℃.
- Analog signal output:Yes , 0-1V.
- Digital signal output:Yes.
- Trigger connector:Yes.
- Sample range:Semi - volatile and non - volatile compounds can be detected.
- Minimum detection:≤2×10-7g/mL (cholesterol/methanol solution).
- Detection reproducibility:RSD6≤2.0%(2×10-4g/mL((cholesterol/methanol solution).
- Communication connector:USB.
- Power:220V±20V,50/60Hz,400W.
- Size:W256*H419*D451mm.
- Quality assurance:two years.
bio-equip.cn