Login    Join free Add to favorites    中文
Home >Products> Plant Physiology | Ecology >Plant Physiology> Living Leaf Area Meter
Plant Physiology | Ecology:  Plant Physiology   Agrology / Ecology  
Living Leaf Area Meter
Living Leaf Area Meter
Origin of place China
Model YMJ-E
Supplier Hangzhou TOP instrument Co., Ltd.
Price 2000 USD
Hits 929
Updated 11/7/2022
  • Product Detail
  • Company Profile
Characteristics
 
64G Android phone with the APP, wide-angle shooting Single blade analysis, multiple collection of longer blades Measuring various parameters of the blade Export excel form of multiple sets of data and pictures No damage to blade when measurement Better adapt to the thickness of different leaves
 
Technical parameters
Overall size
369*145*150mm (L*W*H)
Measurement accuracy
Single shooting: ±2%;
Stitching shooting:length and width ± 2%, the rest of the data is ± 5% (the result of blade stitching with a width that is too
narrow (< 5mm) will have errors)
Measurement range
Single shooting: width 0-140mm, length 0-105mm
Stitching shooting:width 0-140mm, length 0-∞mm
Product weight
0.9 kg
Software system
Android8.1
Phone size
6.26 inches
Rear camera
Rear four cameras:48 million (color, F1.8 aperture) + 8 million (super wide-angle) + 2 million (macro) + 2 million pixels (depth)
Resolution
1920x1080 pixels
RAM
6GB+128GB
CPU
HUAWEI Kirin 810 (Kirin 810) eight core
 
1. Blade length measurement range: single acquisition range is 0-110 mm (supports multiple images stitching, the longest is at least 2m)
2. Blade length measurement accuracy: single acquisition measurement accuracy is ±1%, splicing accuracy can be controlled within ±2%
3. Blade width measurement range: 0-150 mm
4. Blade width measurement accuracy: single acquisition measurement accuracy is ±1%, splicing accuracy can be controlled within ±2% 5. Aspect ratio measurement range: 0.00-10.00 6. Measurement accuracy of aspect ratio: single acquisition measurement accuracy is ±2%, splicing accuracy can be controlled within ±2% 7. Perimeter measurement range: 0-1,000 mm 8. Perimeter measurement accuracy: single acquisition measurement accuracy is ±2%, splicing accuracy can be controlled within ±3% 9. Area measurement range: 0-1,000,000 mm2 10. Area measurement accuracy: single acquisition measurement accuracy is ±1%, splicing accuracy can be controlled within ±2% 11. Form factor range: 0.00-1.00 12. Form factor measurement accuracy: single acquisition measurement accuracy is ±2%, splicing accuracy can be controlled within ±5% 13. Shape factor range: 0.00-1.00 14. Shape factor measurement accuracy: single acquisition measurement accuracy is ±2%, splicing accuracy can be controlled within ±5%
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号