Login    Join free Add to favorites    中文
Home >Products> Other Lab Equipments >Miscellaneous> Multiparameter Monitor MD9000s
Multiparameter Monitor MD9000s
Multiparameter Monitor MD9000s
Origin of place China
Model MD9000s
Supplier Meditech Group Co.,Ltd.
Price
Hits 1504
Updated 9/19/2010
  • Product Detail
  • Company Profile
Meditech MD9000s has a 12.1"color TFT monitor. With ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options, MD9000s almost covers all the measurements of vital signs. A maximum 72 hours storage capacity can save for 500 units of NIBP measurement data, 72 alarm events and 32 seconds waveform for history review.

High resolution 12.1” color TFT display
Light weight, compact and portable
ECG, SP02, NIBP, RESP .2-TEMP. PR
Built-in rechargeable lithium battery
ECG waveforms of 7-leads display on the same screen
72-hours graphic and tabular trends of all parameters
72 alarm events of all parameters recall
32 seconds full-disclosure waveform review
500 NIBP measurement data can be storage and recall
Data and waveforms color be adjustable
Arrhythmia analysis and S-T segment analysis
Suitable for adult, pediatric and neonatal patient
Optional: 2-IBP, ETC02 and thermal printer

ECG:




5-lead or 3-lead selectable

Input: 5-lead:
RA; LA; RL; LL; V or R; L; N; F; C

Lead selection:
I; II; III; avR; avL; avF; V

Gain selection:
x0.25; x0.5; x1; x2

Sweep speed:
12.5mm/s, 25mm/s, 50mm/s

Accuracy:
±1bpm or ±1%, whichever is greater

Protection:
Withstand 4000VAC/50Hz voltage

in isolation against electrosurgical interference and defibrillation

Calibration signal:
1mV±5%

Operation modes:
Diagnostic, Monitor, Surgery

Alarm range: Adult:
15-300bpm

Pediatric/Neonatal:
15-350bpm

S-T detection:
YES

Alarm range:
-2.0mV~2.0mV

Arrhythmia analysis:
YES

Alarm:
YES, audible and visual alarm, alarm events recallable









NIBP:




Method:
Oscillometry

Operation modes:
Manual/Automatic/STAT

Measurement unit:
mmHg/KPa selectable

Measurement types:
Systolic, Diastolic, Mean

Measurement range:
Adult: 10-270mmHg

Over-pressure protection:
YES

Resolution:
1mmHg

Accuracy:
Mean error and standard deviation per ANSI/AAMI SP-10

Alarm:
Systolic, Diastolic, Mean


SpO2:




Measurement range:
0-100%

Accuracy:
±2digit (70~100%);0~69% unspecified

Alarm range:
0-100%






Respiration:




Method:
RA-All impedance

Operation modes:
Manual/Automatic/STAT

Measurement unit:
mmHg/KPa selectable

Measurement types:
Systolic, Diastolic, Mean

Measurement range:
Adult: 0-270rpm,

Pediatric& neonatal: 0-150rpm




Temperature:




Resolution:
0.1℃

Channel:
Dual-channel

Alarm range:
0-50℃





Options:




EtCO2 , IBP , Recorder



bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products
Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号