Chemtron Hydrogen Generators offer a safe, economical, and convenient alternative to gas cylinders. The HK Plus Series provides superior performance with proprietary electrolytic cell technology combined with high quality components and a unique hydrogen drying solution. Ideal for use with gas chromatography detectors such as FID, NPD, and TCD.

HK PLUS SERIES
FEATURES:
* Flow rate from 100 to 250 ml/min

* Purity 99.9996%
* Pressure up to 7 bar (100 psig)
*  Minimal maintenance
* Unique drying membrane - no desiccant cartridges required
* Unique 100% titanium electrolytic cell
* 2 year standard warranty

Benefits
IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

Specifications

Modes HKH2-100 plus HKH2-160 plus HKH2-250 plus
Flow rate (ml/min) 100 160 250
Weight (kg) 17 17 17
Cascading None
Purity 100.00%
Display Parameters, Status, Alarms
LED Indicators On / off, Ready, Error
Membrane Polymer Electrolyte Membrane(PEM)
Dryer Exclusive static system dryer
Max Outlet Pressure adjustable up to 7 bar (102 psig)
Internal Volume <50 ml at max pressure
Water quality Deionized or demineralized (<10uS)
Connections 1/8 swagelock
Power 110-120 60 Hz / 220-240 50 Hz
Dimensions(mm) 230W x 430H x 353L
Certi_cations CE, CSA, FCC
Options RS232C or RS485, Autore_ll, External contracts, PC-control

 

PG PLUS SERIES
FEATURES:

* Flow rate from 100 to 600 ml/min
* Purity 99.9999%
* Pressure up to 11 bar (160 psig)
* Minimal maintenance
* Unique drying membrane - no desiccant cartridges required
* Unique 100% titanium electrolytic cell
* 2 year standard warranty

Benefits
CASCADING

The ability to "cascade", or install several hydrogen generators in parallel, provides:

* Higher flow rates - up to 10 lpm
* Automatic flow compensation in the event of unplanned downtime
* Continous operation for critical applications

IMPROVED SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkalinesolution are Used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purity.

Specifications

Models PGH2-100 plus PGH2-160 plus PGH2-250 plus PGH2-300 plus PGH2-500 plus PGH2-600 plus
Flow rate (ml/min) 100 160 250 300 500 600
Weight (kg) 17 17 17 17 18 18
Purity 100.00%
Display Operating parameters, system status, alarms and touch screen
LED Indicators Power on/off, system ready, errors
Membrane Polymer Electrolyte Membrane(PEM)
Dryer Exclusive cold dual dynamic regeneration system
Max Outlet Pressure 11 bar (160 psig)
Internal Volume <50 ml at max pressure
Water quality Deionized or demineralized (<10uS)
Cascading The exclusive cascading option allows up to 32 units to be connected in series, producing _ow-rates of up to 20 litres also via Intranet
Connections 1/8 swagelock
Power 110-120 60 Hz / 220-240 50 Hz
Dimensions(mm) 230W x 450H x 370D
Certi_cations CE, CSA, FCC
Options RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet


NM PLUS SERIES FEATURES:
* Flow rate from 100 to 1000 ml/min
* Purity 99.99999%
* Pressure up to 11 bar (160 psig)
* No maintenance
* Unique patented automatic dryer system
* Unique 100% titanium electrolytic cell
* 2 year standard warranty

Benefits
CASCADING

The ability to "cascade", or install several hydrogen generators in parallel, provides:

* Higher flow rates - up to 10 lpm
* Automatic flow compensation in the event of unplanned down-time
* Continuous operation for critical applications

IMPROVED CHROMATOGRAPHIC RESULTS
Hydrogen as a carrier gas is faster and more sensitive than the more expensive helium, providing run time savings of 25% to 35% without a decline in resolution.

SAFETY
The very limited internal volume (less than 50 ml) allows safe use of the gas generators where the use of cylinders is risky or prohibited. The application of tested safety technologies stops the unit in the event of leaks or malfunctions.

SAVINGS
Hydrogen gas generators avoid the need for expensive installation of gas pipelines from the cylinder storerooms to the labs, as well as the need to repeatedly change the bottles.

LONGER ANALYTICAL COLUMN LIFE
The use of hydrogen as a carrier gas allows lower temperature elution, thus extending the life of the chromatograph column.

OPERATING PRINCIPLE
Hydrogen is produced by forcing distilled or deionized water through a sophisticated Swiss-made fuel cell. Electrolytic dissociation separates the water into its two main components: hydrogen ready for analytical use, and oxygen that is released into the air. No acid no alkaline solutions are used in the hydrogen generation cycle. The patented automatic drying system ensures the maximum grade of hydrogen purit.

Specifications

Models NMH2-100 plus NMH2-160 plus NMH2-250 plus NMH2-300 plus NMH2-500 plus NMH2-600 plus NMH2-1000 plus
Flow rate (ml/min) 100 160 250 300 500 600 1000
Weight (kg) 17 17 17 17 18 18 20
Cascading Yes (up to 32 units)
Purity 100.00%
Display Operating parameters, system status, alarms and touch screen
LED Indicators Power on/off, system ready, errors
Membrane Polymer Electrolyte Membrane(PEM)
Dryer Exclusive cold dual dynamic regeneration system
Max Outlet Pressure 11 bar (160 psig)
Internal Volume <50 ml at max pressure
Water quality Deionized or demineralized (<10uS)
Cascading The exclusive cascading option allows up to 32 units to be connected in series, producing _ow-rates of up to 32 litres also via Intranet
Connections 1/8 swagelock
Power 110-120 60 Hz / 220-240 50 Hz
Dimensions(mm) 230W x 450H x 370D
Certi_cations CE, CSA, FCC
Options RS232/RS485 and USB, autore_ll, external contacts, PC control, Intranet
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products
Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号