TWO CHANNEL FID GAS CHROMATOGRAPH
TWO CHANNEL FID GAS CHROMATOGRAPH
Origin of place China
Model 126/136N
Supplier SMT labtech company
Price 1
Hits 764
Updated 4/14/2025
  • Product Detail
  • Company Profile

Technical Feature

●The host adopts a 7-inch color touch screen, with a user-friendly human-machine exchange interface.

● Computer reverse control and host touch screen achieve synchronous bidirectional control.

●A multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.

● Digital display of carrier gas/hydrogen/air path flow (pressure).

●Equipped with air shortage alarm protection function; Heating control protection function (when opening the column box door during use, the column box fan motor and heating system automatically turn off).

●The split flow rate/split ratio can be automatically controlled to save carrier gas.

●Configure the installation and positioning interface of the automatic sampler, which can match various specifications of automatic samplers.

●The data collection is equipped with a standard dual channel data collection card, with a sampling time of 50ms.

●Using a logarithmic amplifier board, the detection signal has no cut-off value, and the synchronous external trigger function can be used to start the host and workstation simultaneously by external signals (such as automatic samplers, thermal analyzers, etc.).

●Equipped with comprehensive system self inspection function and automatic fault identification function.

●Equipped with an extended functional interface for 8 external events, it can be equipped with various control valves and operate according to its own set timing.

●The external connection method is network port connection (RJ45), providing convenience for remote control of data.

 

Column temperature box:

●Temperature range: 5 ℃~400 ℃ above room temperature

Temperature control accuracy: ± 0.1 ℃

● Program heating up: 9th order/10th platform

●Total program time: 9999.9 minutes

●Heating rate (MAX): 60 ℃/min

 

Sampler:

●Temperature range: 7 ℃~420 ℃ above room temperature

●Can be installed with filling columns and split/non split injectors

●Working in constant voltage mode

●At most three injection systems can be connected simultaneously

 

Hydrogen flame ionization detector (FID):

●High voltage switch control

●Baseline signal display

●Ignition coil control

●Detection limit: ≤ 3 × 10-12 g/s

●Sample: n-neneneba hexadecane (detection amount: 3pg/s)

●Dynamic range: 107

 

if need price,please email us to

Ellen

International Marketing Manager
SMTlabtech
Add: No.2208,Xinluo Road,Jinan,Shandong, China
Mobile:+8617357274522
(Whatsapp and Wechat)
Email: smtlabtech@126.com
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号