Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
Origin of place China
Model GC112
Supplier Shandong Saikesaisi Hydrogen CO., Ltd
Price 1
Hits 500
Updated 3/16/2023
  • Product Detail
  • Company Profile
Product Introduction
Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
Features & Specification
Feature:
1.Standard PC side reverse control software
2.Host with 7-inch color touch screen
3.Gas shortage alarm protection function
4.Split flow/split ratio can be automatically controlled to save carrier gas.
5.Configure automatic sampler installation and positioning interface 
6.The multi-core, 32-bit embedded hardware system 
7.Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function
8.One-button start function
9.It has perfect system self-check function and fault automatic identification function.
10.With 8 external event extension function interface
11.RS232 communication port and LAM network port


Technical Specifications:
Column temperature box
Content product
22L
Temperature control range
5ºC ~ 400ºC at room temperature
Temperature control accuracy
±0.1ºC
Heating rate
0.1 ~ 60ºC / min
Program temperature rise order
9
Program heating repeatability
≤ 2%
Cooling way
open the door after
Cooling speed
≤10 mins (250ºC ~ 50ºC)
Control software function
(GC112N only)
Column temperature box control
Detector control
Injector control
Map display
Sampler
Temperature control range
7ºC ~ 420ºC at room temperature
Temperature control method
independent temperature control
Carrier gas flow control mode
constant pressure
Number of simultaneous installations
3 at most
Type of injection unit
filling column, shunt
Split ratio
split ratio display
Cylinder pressure range
0 ~ 400kPa
Cylinder pressure control accuracy
0.1kPa
Flow setting range
H2 0 ~ 200ml / min
N2 0 ~ 150ml / min
Detector
FID, TCD optional
Temperature control
Max. 420ºC
Number of simultaneous installations
2 at most
Ignition function
automatic
Hydrogen flame ionization detector (FID)
Detection limit
≤ 3×10 g/s (n-hexadecane)
Baseline noise
≤ 5× 10-14A
Baseline drift
≤ 6× 10-13A
Dynamic range
107
RSD
3% or less
Thermal conductivity detector (TCD)
Sensitivity
5000mV•mL/mg (n-cetane)
Baseline noise
≤ 0.05 mV
Baseline drift
≤ 0.15mV / 30min
Dynamic range
105
Supply voltage
AC220V±22V, 50Hz±0.5Hz
Power
3000W
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号