Login    Join free Add to favorites    中文
Home >Products> Spectrum | HPLC | GC | MS >Gas Chromatograph> GC-8120 suit of gas chromatography
GC-8120 suit of gas chromatography
GC-8120 suit of gas chromatography
Origin of place China
Model GC 1820
Supplier Hua Guang analysis instrument company
Price
Hits 2537
Updated 1/22/2010
  • Product Detail
  • Company Profile
GC-8120 suit of gas chromatography made with excellent sensibility, good stability, accurate ration and character scale. Instrument enable to install 3 sampling port, 5 detector, 2 packed column and capillary column, these effectively connected in same column chamber. It can be wild used among petroleum, chemical industry, pharmacy, board of health, environment protection, university etc.

Enable to install 2 packed columns sampling ports, 1 capillary column sampling port (distributary/ distributary less), effectively arranged and installed1-5 different kinds of detectors (TCD, FID, ECD, FPD, NPD). Packed and capillary columns enable to optional select relative detectors. It can achieve series and parallel detector connection.

Double packed columns, double sampling ports, double gas circuits effectively control baseline fluctuation and excursion, suitable for program temperature analysis. Double sampling port have 3 optional forms: top injection, VARIAN instantaneous vaporization sampler, six-way valve auto gas sampler.

Specific capillary column sampler: independent carrier gas circuit system, make up gas circuit, gas circuit with septum cleaning and distributary flow pass with back pressure valve control. it is effective less to column flux; back pressure valve control largely decreases the distributary disproportion effects from column pressure fluctuation; make up gas system guarantee good peak shape and high sensibility for best operation; gas circuit with septum cleaning function corrects ghost peak. Above well-designed capillary column sampling system is very suitable for complex sample testing, also effectively prevents ghost peak generation from sampling process in high temperature. There are few optional methods for sampler to achieve Grob stop flow injection: distributary/ distributary less, capillary column with wild caliber direct injection and magnet valve with time program distributary gas circuit on off. Very suitable for trace material testing.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Recently viewed products
Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号