Pilot scale protein purification system
The AUTOPURE PILOT600 has flexible configuration options,
It supports the chromatographic column with a diameter of 26mm - 200mm, compact size, table top placement and convenient movement. The functional components are all located on the front of the equipment for easy operation;
The system control software adopts humanized design and interactive interface, which makes operation and automatic editing more convenient and fast; The high precision and large flow plunger pump ensures stable flow rate and gradient configuration, and can cover a variety of small scale, pilot scale and small-scale production chromatographic columns;
The accurate detector system can monitor the fixed wavelength, variable wavelength UV absorption, conductivity and pH online, accurately monitor and record various data of each operation, and provide data analysis function and report generation function in the software to ensure the integrity of the experiment.
System performance parameters:
Two pump system A/B pump, two pumps
Flow rate range: 4-600ml/min (double pump overlapping column loading mode: 1 – 1200ml/min)
Acceptable range: 5% - 95%
Pressure range: 0 – 2MPa (20bar, 290 psi)
Viscosity: 0.7-10 cp
UV detector 280 nm fixed wavelength detector LED light source, service life > 8000h
Detection range: - 6 -+6AU
Linearity: ± 2%
Wavelength accuracy: ± 2nm
Wavelength repeatability: ± 1 nm
Noise: ± 1 * 10-4AU (1S)
DAD200-400nm, dual wavelength detection DAD full spectrum direct reading detector, 200-400nm variable dual wavelength
Wavelength accuracy: ± 2nm
Wavelength repeatability: ± 1 nm
Noise: ± 1 * 10-4AU (@ 254nm, 1S)
   
Optical fiber conduction, external flow cell, to avoid the influence of light source temperature on the activity of protein samples, double beam design, with high stability.
Standard flow cell: 2mm optical diameter, 20ul flow cell volume, maximum pressure resistance 2Mpa
Conductivity detector Detection range: 0.1mS/cm - 999.9mS/cm
Volume of test cell: 20ul
Conductivity accuracy: ± 3% or 0.2mS/cm; Built in temperature sensor for automatic conductivity compensation calibration
Temperature detector Temperature range: 0 - 99 ° C; Temperature accuracy: ± 2 ° C at 2 ° C – 50 ° C
PH detector Detection range: 2-12; Accuracy: ± 0.15
Import selection Single pump 4 inlet
8 inlets in total for two pumps
It can be expanded to 12 imports
Maximum 8 outlets
Column position valve 1 column position,3 column position
Bubble trap Effectively discharge bubbles from the system, online or offline
mixer Volume of mixing chamber: 12ml
Bubble sensor Support up to 3
Pressure sensor A. One at the back of pump B, one at the front of the column, one at the back of the column, four in total, with the detection range of 0-2MPa
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号