FEATURES:
Innovated rich oxygen air-acetylene flame analysis technique (WFX-110B)
The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950℃, which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It’s a break-through in flame AAS analysis.
Flame atomization system with flame emission burner
A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc. (AE-WFX110B/120B)
Accurate fully automated control system
- Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position.
- Automatic wavelength scanning and peak picking
- Automatic spectral bandwidth changing
- Automatic ignition
Perfect safety protection measures
- Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
Advanced and reliable electronic design
- Adopting large-scale programmable logic array and Inter I2C bus technology
- European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.
Easy and practical analysis software
- Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
- Automatic display of measured data, automatic calculation and analytical result automatic print out.
SPECIFICATIONS:
Main Specification
|
Wavelength range
|
190-900nm
|
Wavelength accuracy
|
±0.25nm
|
Resolution
|
Two spectral lines of Mn at 279.5nm and
279.8nm can be separated with the spectral
bandwidth of 0.2nm and valley-peak energy
ratio less than 30%.
|
Baseline stability
|
≤0.004A/30min
|
Background correction
|
The D2 lamp background correction
capability at 1A is better than 30 times.
The S-H background correction capability at
1.8A is better than 30 times. (only for
WFX-110B/120B)
|
Light Source
|
Lamp turret
|
6-lamp turret (WFX-110B/120B),
4-lamp turret (WFX-130B)
auto alignment, fully automated scan and
peak-picking.
|
Lamp current adjustment
|
Automatic adjustment and display.
Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA
|
Lamp power supply mode
|
400Hz square wave pulse
100Hz Narrow square wave pulse + 400Hz
wide square wave pulse (WFX-110B/120B)
|
Optical System
|
Monochomator
|
Single beam, Czerny-Turner design grating
monochromator
|
Grating
|
1800 l/mm
|
Focal length
|
277mm
|
Blazed Wavelength
|
250nm
|
Spectral Bandwidth
|
0.1nm, 0.2nm, 0.4nm, 1.2nm automatic
change.
|
Flame Atomizer
|
Burner
|
10cm single slot all-titanium burner
|
Spray chamber
|
Corrosion resistant all-plastic spray chamber.
|
Nebulizer
|
High efficiency glass nebulizer with metal
sleeve, sucking up rate: 6-7mL/min
|
Emission burner
|
Provided with WFX-110B/120B
|
Detection and Data Processing System
|
Detector
|
R928 Photomultiplier with high sensitivity and
wide spectral range.
|
Software
|
Windows operating system
|
Analytical method
|
Working curve auto-fitting; standard addition
method; automatic sensitivity correction; automatic calculation of concentration and ontent.
|
Repeat times
|
Maximum 20 times of repeat measurement,
automatic calculation of mean value,
standard deviation and relative standard
deviation.
|
Multi-task function
|
Sequential measurement of multi-elements in
one sample
|
Condition reading
|
With model function
|
Result printing
|
Measurement data and final analytical report
printout, editing with Excel.
|
Standard RS-232 serial port communication
|
Characteristic Concentration and
Detection Limit
|
Normal Air-C2H2 flame
|
Cu: Characteristic concentration≤0.025mg/L,
Detection limit≤0.006mg/L;
|
Oxygen-rich Air-C2H2 flame
|
Ba: Characteristic concentration ≤ 0.22mg/L
Al: Characteristic concentration ≤ 0.4mg/L
(for WFX-110B)
|
Function Expansion
|
Hydride vapor generator can be connected for hydride analysis.
|
Dimensions and weight
|
1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg
|
If you are interested in our products, pls feel free to contact me via email:
dvp@aelabcn.com
bio-equip.cn
A&E Labmed Co., Ltd have many years of manufacturing and selling wide range of scientific and laboratory instruments. Our products mainly include: UV VIS Spectrophotometer, Visible Spectrophotometer, PCR Cycler, Stirrer Hotplate, Shaker, Rocker, Block Heater, Mixer, PH/Conductivity/TDS/Salinity/Dissolved Oxygen/Free Chlorine Meter, Halogen Moisture Analyzer, Ultrasonic Cleaner and Microscope, etc.
|