Login    Join free Add to favorites    中文
Home >Products> Spectrum | HPLC | GC | MS >Spectrophotometers> AELAB 4530F Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer
AELAB 4530F Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer
AELAB 4530F Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer
Origin of place China
Model 4530F
Supplier AELAB Guangzhou
Price
Hits 38
Updated 12/10/2025
  • Product Detail
  • Company Profile

AELAB 4530F Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer


Advanced AAS for precise multi-element quantification with floated optical platform stability, automatic 8-lamp turret, and PC-controlled flame/graphite furnace workflows.

Deuterium background correction, rapid wavelength scanning, and robust data handling (>500 records) support high-throughput environmental, pharmaceutical, and metallurgical testing.


Category Insight: Atomic absorption spectrophotometers for trace metal analysis with flame, graphite furnace, and hydride options.
 

🔗 Explore related category


Technical Features and Specifications
Feature Details
Optical System Single-beam on floated optical platform for anti-vibration stability
Wavelength Range 190–900 nm; scanning grating 1800 lines/mm
Spectral Bandwidths 0.1, 0.2, 0.4, 1.0, 2.0 nm selectable
Wavelength Accuracy / Repeatability ±0.15 nm / ≤0.04 nm
Baseline Stability (Cu) ≤0.002 A / 30 min
Sensitivity & Detection (Cu) Characteristic 0.02 μg/ml/1%; detection limit ≤0.004 μg/ml
Lamp Turret Automatic 8-position turret with preheating & auto selection
Background Correction D2 lamp; 1 A background reduced ≥50× (self-absorption method)
Atomization (Flame) All-metal titanium burner 100 mm; effective glass atomizer; ignition drift ≤0.006 A/30 min
Flame Precision (Cu) RSD ≤0.5% (A > 0.8); detection limit ≤0.008 μg/ml
Graphite Furnace (4510GF) Up to 3000 °C; heating rate ≥2000 °C/s; Cd ≤0.5×10−12 g, Cu ≤0.5×10−11 g; accuracy Cu/Cd ≤3%
Control & Software Full PC control; auto wavelength scanning; method/result storage >500; Excel/report print
Safety Interlocks Auto gas cut-off (low pressure), power-fail & flameout protection; burner mismatch detection
Interfaces / Options USB, RS-232; hydride generator, chiller, air compressor (optional)
Power Main unit 220 V ±22 V AC; graphite furnace 220 V ±22 V AC, 7000 W
Dimensions (Pkg.) Main 860×705×755 mm; Accessories 1170×645×900 mm

Applications: Environmental monitoring (water/soil), food safety, agricultural nutrients, pharmaceutical formulation, metallurgical alloy control, and biochemical research — compliant with ISO, GLP, and CE quality standards.



FAQ

Q: What is the wavelength range of the AELAB 4530F?

A: 190–900 nm, covering common resonance lines for multi-element metal analysis.

Q: Does it support both flame and furnace?

A: Yes. Standard flame AAS with optional 4510GF graphite furnace for ultra-trace measurements.

Q: How many lamps can be installed?

A: An 8-lamp automatic turret enables quick switching and simultaneous preheating.

Q: What is the Cu detection limit?

A: ≤0.004 μg/ml (flame); characteristic 0.02 μg/ml/1%.

Q: What safety features are included?

A: Automatic gas cut-off, power-fail protection, flameout protection, and burner mismatch safeguards.

Q: What data handling functions are available?

A: On-board storage for >500 records/methods, USB/RS-232 connectivity, Excel export, and printouts of parameters, results, and spectra.

Learn more: Visit AELAB 4530F Atomic Absorption Spectrophotometer


📞 Contact AELAB

Get Expert Advice or Order Now ☎️

🌐 Website: www.aelabgroup.com
📧 Email: info@aelabgroup.com
📱 WhatsApp / WeChat: +86 15800016110

🔎 Need guidance on flame vs. graphite furnace methods? Our technical team can help tailor a configuration to your analytes and detection limits.

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号