Line-gene K Real-time PCR Detection System
Line-gene K Real-time PCR Detection System
Origin of place China
Model Line-Gene.K-FQD-48A(A4)/(M2)
Supplier Hangzhou Bioer Technology Co.,Ltd
Price
Hits 12942
Updated 3/23/2020
  • Product Detail
  • Company Profile
Line-Gene. K is the newest system in Bioer''s range of PCR detection systems. It features more advanced implementations of Peltier and fiber optic technology and a new direct current power system.

The new instruments share the Peltier effect and fiber optic design features that provide the exceptional accuracy and stability of the Line-Gene instruments.The new units offer improved uniformity,stability and accuracy by utilizing a constant-current power supply and an advanced multi-point temperature control module.The Line-Gene.K has improved temperature control and more uniform heating throughout the sample block to improve the accuracy of PCR detection.

The Line-Gene.K series is available in a range of automated and manual models with the ability to handle one, two, three or four combinations of excitation and emission wavelengths.

15 items(just for you!)
●Volume adaptation—software automatically adjusts heat exchange to differences in sample volumes.
●New multipoint temperature monitoring allows more accurate and uniform temperature control throughout the heating block.
●Gradient function—creates a temperature gradient across the sample block. Maximum 24℃ difference between row 1 and row 24.
●Sample preservation—after completion of experiment, the system can automatically refrigerate samples until they are moved to storage.
●Use of direct current power supply improves thermal efficiency and reduces power consumption by 30%.
●Improved optics—greater efficiency in fiber optic system provides reduced signal to noise ratio.
●Automatic hot lid—provides constant pressure and software-managed temperature control.
●Configuration upgradable—manual versions of the instrument can be upgraded to automatic. Systems can be upgraded from 1 wavelength to 4 wavelengths.
●Numerous data ports—choose from serial(RS 232),USB and ethernet connections for PC data interface.
●Multiple tube styles—the sample block will accept several styles of 0.2ml tubes including 8-tube strips.
●Data protection—system preserves experimental data if there is a power interruption during operation.
●Automatic amplitude adjustment—the instrument detects the fluorescence strength in the samples and automatically adjusts to the correct system sensitivity.
●New software—a new generation of Line-Gene software provides even greater convenience and more powerful functions.
●Upload software instructions—define experiment instructions with easy-to-use PC- based software,then upload to instrument.
●Overheating protection—if the operating environment exceeds the temperature range for operation within specification, the instrument will shut down.At 35℃the instrument will sound a warning;it will turn off at 40℃.

SNPs Detection
Line-Gene system is a multicolor fluorescence detection system and can carry out the detection analysis of SNPs.

2nd Derivative Maximum:
This method automatically calculates the maximum second derivative value of every fluorescent curve and defines this value as the Ct value.

Fit Points:
The user sets baseline and a threshold values then draws a threshold line.Based on user instructions,the software will select a number of sample points on the fluorescence curve that are above baseline and in the logarithmic phase into a line.The intersection of this line with the threshold line is defined as the Ct value.















































































Model


FQD-48A (A4)
(A4: means automatic
lid and 4 channels)


FQD-48A (M2)
(M2: means manual
lid and 2 channels)


Sample Capacity


48×0.2ml


48×0.2ml


Reaction System


10~100μl


10~100μl


Dynamics Range


10~1010Copies


10~1010Copies


Max.Channel Number of
Fluorescence Detection


4 Channels


2 Channels


Excitation Light Wavel
length (450-590mm)


Standard Positioning
F1: 470nm F2: 523nm
F3: 543n F4: 571nm


F1: 470nm F2: 523nm


Fluorescence Detecting
Wavelength (500-630nm)


Standard Positioning
F1: 525nm F2: 564nm
F3: 584n F4: 612nm


F1: 525nm F2: 564nm


Detecting Fluorescence


FAM, SYBR Green I, HEX, VIC, TAMRA,
TEX RED, ROX


FAM,SYBR Green,HEX


Temp. Range


4~99.9


4~99.9


Heating Rate (Max)


4.0/sec


4.0/sec


Cooling Rate


4.0/sec


4.0/sec


Temp. Uniformity of Block


≤±0.3


≤±0.3


Temp. Control Accuracy


≤±0.1


≤±0.1


Gradient Temp. Range


1~24


1~24


Hot-lid Temp. Range


80~120


80~120


Operation System


Windows 2000/XP


Windows 2000/XP


Power Supply


AC220V 50Hz 500W


AC220V 50Hz 500W


Dimension (mm)


520×450×320(L×W×H)


520×450×320(L×W×H)


Net Weight


25Kg(Without computer)


25Kg(Without computer)

bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2025 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号