Home >Products> Medical Lab Instruments >Other Medical Lab Instruments> TC-150O1 Fully‑Enclosed Vacuum Tissue Processor
TC-150O1 Fully‑Enclosed Vacuum Tissue Processor
TC-150O1 Fully‑Enclosed Vacuum Tissue Processor
Origin of place China
Model TC-150O1
Supplier Hubei Taiva Technology Co.,Ltd
Price 350000¥
Hits 83
Updated 5/21/2026
  • Product Detail
  • Company Profile

A critical instrument for histopathology. It performs dehydration, an essential pre-processing step before tissue embedding and sectioning. Dehydration quality directly impacts the final sectioning outcome and diagnostic accuracy.

Features


1.Fully enclosed vacuum design – No leakage of hazardous fumes, compliant with environmental protection requirements.

2.Delay start function – User-adjustable preset operation time.

3.Self-diagnostic system – Equipped with operation alarm, power-on self-test, and fault self-diagnosis functions.

4.Real-time monitoring – Multi-parameter display allows users to check instrument working status at any time, including program content, heating status, and temperature settings.

5.Intelligent power failure protection system – Protects running cycles during unexpected power outages.

6.Low-voltage anti-clogging technology for paraffin path – Backup low-voltage heating system prevents paraffin solidification and pipe blockage caused by power interruption.

7.Adjustable rinse cycles – User-defined number of rinse cycles for each cleaning agent; the final rinse cycle features heating technology to ensure pipeline patency before operation.

8.Remote monitoring via Wi-Fi – Enables abnormal condition alerts sent to a mobile device.

9.Gradient reagent replacement function – Reagent management system with purity assurance alert for timely reagent change.

10.Maximum specimen capacity – 320 standard cassettes per run.

Technical Data:

No.
Parameter Item
Parameter Specification
-
Tissue Sample Capacity
≥ 325 tissue cassettes
1
Tissue Sample Basket Structure
≥ 3 layers; the number of layers used can be determined according to the number of samples. The tissue basket is made of stainless steel wire, facilitating filtration without residue.
2
Effective Capacity of Tissue Processing Cylinder / Reagent Kettle
Effective capacity of tissue processing cylinder: ≥ 6L; Effective capacity of reagent kettle: ≤ 5.5L
3
Effective Capacity of Paraffin Cylinder
≥ 5L × 3
4
Working Pressure
0.07Mpa ~ 0.15Mpa
5
Scheduled Startup Time Range
Any time
6
Paraffin Temperature Range
55℃ ~ 85℃
7
Working Cylinder Temperature Range
Room Temperature ~ 65℃
8
Liquid Feeding Time / Liquid Retraction Time / Paraffin Feeding Time / Paraffin Retraction Time
Liquid feeding time: 1 ~ 15 minutes (adjustable); Liquid retraction time: 1 ~ 15 minutes (adjustable); Paraffin feeding time: 1 ~ 15 minutes (adjustable); Paraffin retraction time: 1 ~ 15 minutes (adjustable)
9
Running Time
1 second ~ 99 hours 59 minutes (adjustable)
10
Cleaning Method
3 bottles of cleaning fluid; the number of single-bottle cleaning times can be set from 1 to 99; the last bottle can be heated
11
Running Mode
Two modes: Manual and Automatic
bio-equip.cn
Request Infomation

* Name:
Title:
* Tel:
Fax:
* E-mail:
Postcode:
Institution/Company:
Address:
* Country:
Request infomation:
yes no
Request Quotation:
yes no
* Message:
Validated Code:
refresh
I agree to share my inquiry to the other matching suppliers.



Copyright(C) 2006-2026 Bio-Equip    E-mail:web@bio-equip.cn   沪ICP备06040519号