AELAB AE-LAI-D2 Anaerobic Workstation
A fully integrated oxygen-free microbial incubation system designed for culturing anaerobic and microaerophilic organisms with precise control of temperature, CO₂, humidity, and gas composition.
Ideal for clinical, pharmaceutical, and research labs requiring strict anaerobic conditions with intelligent automation and continuous operation capability.
Category Insight: Specialized anaerobic incubators and workstations engineered for controlled oxygen-free microbial culturing.
🔗 Explore related category
Technical Features and Specifications
| Feature |
Details |
| Model |
AE-LAI-D2 |
| Time to Create Anaerobic State (Sample Chamber) |
<5 min |
| Time to Create Anaerobic State (Operation Chamber) |
<1 h |
| Anaerobic Environment Maintenance |
>13 h (no gas supply) |
| Temperature Range |
RT+3 – 60 °C |
| Temperature Stability |
±0.3 °C |
| Temperature Uniformity |
±1 °C |
| CO₂ Range |
0–20 % |
| CO₂ Control Accuracy |
±0.1 % (imported sensor) |
| Humidity Control Range |
50–90 % RH |
| Humidity Fluctuation |
±3 % RH |
| Power Rating |
1500 W |
| Power Supply |
AC 220 V, 50 Hz (customizable) |
| Interior Chamber Size |
42 × 29 × 47.5 cm |
| Operation Chamber Size |
95 × 67 × 75 cm |
| Sampling Chamber Size |
40 × 30 × 32 cm |
| Construction |
All 304 Stainless Steel body |
| Package Size |
151 × 92 × 152 cm |
| Accessories |
UV lamp, palladium catalyst, power socket, latex gloves, pressure relief bottle |
Applications: Cultivation of anaerobic and microaerophilic bacteria; clinical pathogen isolation; antibiotic susceptibility testing; biopharmaceutical R&D; food spoilage organism detection; gut microbiome studies; environmental microbial analysis.
FAQ
Q: What is the function of the AELAB AE-LAI-D2 Anaerobic Workstation?
A: It provides a controlled oxygen-free environment for cultivating and handling anaerobic and microaerophilic microorganisms.
Q: How does the workstation maintain anaerobic conditions?
A: It uses vacuum-assisted gas replacement and a palladium catalyst to reduce oxygen concentration below 0.1%.
Q: What are the temperature and CO₂ control capabilities?
A: Temperature RT+3–60 °C and CO₂ 0–20 % with ±0.1 % accuracy.
Q: Can it be used for both anaerobic and microaerophilic cultures?
A: Yes, oxygen levels from 0–10% allow flexible incubation conditions.
Q: How long can it maintain anaerobic conditions without gas?
A: Over 13 hours of stable oxygen-free operation.
Q: What safety features are included?
A: Pressure protection, leakage safeguards, and over-temperature alarms.
Q: What materials are used?
A: Entire chamber is constructed from corrosion-resistant 304 Stainless Steel.
Q: What are the main application areas?
A: Clinical microbiology, food safety, biopharma research, environmental microbial testing.
Learn more: Visit AELAB AE-LAI-D2 Anaerobic Workstation